VARIABLE CAPACITY ABSORPTION COOLING SYSTEM PERFORMANCE FOR BUILDING APPLICATION

Sayfa
2303–2317
Yayın Tarihi
2022-10-18
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Hence, use of the above mentioned system as a heating and/or cooling alternative for buildings is suggested.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The increasing energy costs and environmental awareness call for a shift towards some interesting energy alternatives preferably the use of renewable energy.
📊
Temel Bulgular & Veri:The results obtained from investigation revealed that variation in cooling capacity influences coefficient of performance (COP), exergy loss in different components as well as exergy efficiency.
💡
Sonuç & Katkı:Hence, use of the above mentioned system as a heating and/or cooling alternative for buildings is suggested.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Absorption Refrigeration System · Coefficient of Performance · Exergy Analysis

Abstract

The increasing energy costs and environmental awareness call for a shift towards some interesting energy alternatives preferably the use of renewable energy. The present study investigates the impact of varying cooling capacity and other operating parameters in a single-effect absorption refrigeration system, using the concept of energy and exergy as a building heating/cooling alternative. The solar heat is used as an input to the generator of absorption refrigeration system. The results obtained from investigation revealed that variation in cooling capacity influences coefficient of performance (COP), exergy loss in different components as well as exergy efficiency. The values of COPcooling and COPheating lies in the range of 0.71-0.89 and 1.71-1.89 respectively for variations in cooling capacities ranging from 1 TR to 20 TR at maximum generator temperature of 80oC. However, exergy efficiency of the system lies in the range of 0.32-0.41 for same variation in cooling capacities. It has also been established that an increase in evaporator temperature and at maximum cooling capacity both COPcooling and COPheating shows an increasing trend. The exergy efficiency also shows maximum value at the highest cooling capacity at a particular evaporator temperature which further with an increase in evaporator temperature shows a decreasing trend. The irreversibility behavior in all the components i.e., solution heat exchanger, absorber, generator, evaporator and condenser shows an expected trend with the variation in cooling capacity. Hence, use of the above mentioned system as a heating and/or cooling alternative for buildings is suggested.

🔖

Bu Makaleye Atıf Yap

GUPTA, A., ANAND, Y., TYAGİ, S., ANAND, S. (2022). VARIABLE CAPACITY ABSORPTION COOLING SYSTEM PERFORMANCE FOR BUILDING APPLICATION. Journal of Thermal Engineering, Cilt: 4 - Sayı: 5, 2303–2317. https://ajindex.com/articles/566841

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Ventas, R., Lecuona, A., Vereda, C., Legrand, M. (2016). Two-stage double-effect ammonia/lithium nitrate absorption cycle. Applied Thermal Engineering, 94, 228 - 237
  2. Siddiqui, M. U., Said, S. A. M. (2015). A review of solar powered absorption systems. Renewable and Sustainable Energy Reviews, 42,93 - 115
  3. Pintaldi, S. S., Taylor, R. A., White, S. D., Morrison, G. L., Rosengarten, G. (2015). Solar-Powered Absorption Chillers for Air-Conditioning Applications: Simulation and Techno-Economic Evaluation, In Proceedings of 9th International Conference on Energy Sustainability, collocated with ASME 2015 Power Conference, 13th ASME International Conference on Fuel Cell Science, Engineering and Technology, and the ASME 2015 Nuclear Forum, American Society of Mechanical Engineers
  4. Ghafoor, A., Munir, A. (2015). World-wide overview of solar thermal cooling technologies. Renewable and Sustainable Energy Reviews, 43, 763-774
  5. Lange, M. F. D., Verouden, K. J. F. M., Vlugt, T. J. H., Gascon, J., Kapteijn, F. (2015). Adsorption-driven heat pumps: the potential of metal–organic frameworks. Chemical Reviews, 115(22), 12205 - 12250
  6. Sabek, S., Nasr, K. B., Chouikh, R., Guizani, A. (2015). Analytical Study of a Heat Recovery/Desiccant Cooling System under Tunisian Climatic Conditions. Journal of Clean. Energy Technologies, 3(3), 159 - 164
  7. Sultana, P., Wijeysundera, N. E., Ho, J. C., Yap, C., Chang, T. K. (2015). Effect of vapour absorption enhancement in solar-heat driven air-conditioning system. Journal of Clean Energy Technologies, 3(1), 43 - 47
  8. Quan, S. H., Xu, Z. Y., Wang, H., Wang, R. (2015). A solar/gas fired absorption system for cooling and heating in a commercial building. Energy Procedia, 70, 518 - 528
  9. Li, Y., Hu, R. (2016).Exergy-analysis based comparative study of absorption refrigeration and electric compression refrigeration in CCHP systems. Applied. Thermal. Engineering, 93, 1228 - 1237
  10. Al-Ugla, A. A., El-Shaarawi, M. A. I., Said, S. A. M., Al-Qutub, A. M. (2016). Techno-economic analysis of solar-assisted air-conditioning systems for commercial buildings in Saudi Arabia.Renewable and Sustainable Energy Reviews,54, 1301-1310
  11. Gupta, A., Anand, Y., Anand, S., Tyagi, S. K. (2015). Thermodynamic optimization and chemical exergy quantification for absorption-based refrigeration system. Journal of Thermal Analysis and Calorimetry, 122 (2), 893-905
  12. Abdullah, M. O., Hien, T. C. (2010). Comparative analysis of p