Dergiler / Journal of Thermal Engineering / 2019 / Cilt: 5 - Sayı: 3

EXERGY ANALYSIS OF THE ORGANIC RANKINE CYCLE BASED ON THE PINCH POINT TEMPERATURE DIFFERENCE

Sayfa
157–165
Yayın Tarihi
2022-10-18
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

With the increase of the pinch point temperature difference in the evaporator, the decrease of the system’s exergy efficiency became maximal (11.7%) with the use of R152a as a refrigerant and the loss in the system’s exergy efficiency became minimal (9.03%) with the use of R123 as a refrigerant.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Organic Rankine Cycle (ORC) is a system that uses working fluids with hydrocarbon components instead of water and generates power from the heat recovery of different heat sources.
📊
Temel Bulgular & Veri:In this study, the exergy analysis of a simple ORC, which produces electrical energy with the help a geothermal source (125°C), was performed.
💡
Sonuç & Katkı:With the increase of the pinch point temperature difference in the evaporator, the decrease of the system’s exergy efficiency became maximal (11.7%) with the use of R152a as a refrigerant and the loss in the system’s exergy efficiency became minimal (9.03%) with the use of R123 as a refrigerant.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Organic Rankine Cycle · Exergy Analysis · Pinch Point Temperature

Abstract

Organic Rankine Cycle (ORC) is a system that uses working fluids with hydrocarbon components instead of water and generates power from the heat recovery of different heat sources. In this study, the exergy analysis of a simple ORC, which produces electrical energy with the help a geothermal source (125°C), was performed. R123, R152a, R245fa and R600a were determined as the fluids to be used in the Cycle. In this analysis, which was carried out according to the pinch point temperature differences (5-20°C) in the evaporator, the exergy performance of the cycle components was evaluated for the geothermal resource unit flow rate and the variation of the exergy efficiency of the system was calculated. With the increase of the pinch point temperature difference in the evaporator, the decrease of the system’s exergy efficiency became maximal (11.7%) with the use of R152a as a refrigerant and the loss in the system’s exergy efficiency became minimal (9.03%) with the use of R123 as a refrigerant.

🔖

Bu Makaleye Atıf Yap

YAMANKARADENİZ, R., BADEMLİOĞLU, A. H., KAYNAKLI, Ö. (2022). EXERGY ANALYSIS OF THE ORGANIC RANKINE CYCLE BASED ON THE PINCH POINT TEMPERATURE DIFFERENCE. Journal of Thermal Engineering, Cilt: 5 - Sayı: 3, 157–165. https://ajindex.com/articles/566787

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Bertrand, F.T., George, P., Gregory, L., Antonios, F. (2009). Fluid selection for a low-temperature solar Rankine cycle. Applied Thermal Engineering, 29, 2468-2476
  2. Drescher, U., Bruggemann, D. (2007). Fluid selection for the Organic Rankine Cycle (ORC) in biomass power and heat plants. Applied Thermal Engineering, 27, 223-228
  3. Rayegan, R.,Tao, X. (2011). A procedure to select working fluids for solar Rankine cycle (ORCs). Renewable Energy, 36, 659-670
  4. He, C., Liu, C., Gao, H., Xie, H., Li, Y., Wu, S., Xu, J. (2012). The optimal evaporation temperature and working fluids for subcritical organic Rankine cycle. Energy, 38, 136-143
  5. Quoilin, S., Van den Broeck, M., Declaye, S., Dewallef, P., Lemort, V. (2013). Techno-economic survey of Organic Rankine Cycle (ORC) systems. Renewable & Sustainable Energy Reviews, 22, 168-186
  6. Wang, Y., Ding, X., Tang, L., Weng, Y. (2016). Effect of evaporation temperature on the performance of organic Rankine Cycle in near-critical condition. ASME Journal of Energy Resources Technology, 138, 032001-032008
  7. Ergun, A., Ozkaymak, M., Kılıcaslan, E. (2016). Power generation applications with Organic Rankine Cycle from low temperature heat sources. Duzce University Journal of Science & Technology, 4, 686-696
  8. Kaynakli, O., Bademlioglu, A.H., Yamankaradeniz, N., Yamankaradeniz, R. (2017). Thermodynamic analysis of the Organic Rankine Cycle and the effect of refrigerant selection on cycle performance. International Journal of Energy Applications and Technologies, 4, 101-108
  9. Akkaya, A.V. (2017). Performance analyzing of an organic Rankine cycle under different ambient conditions. Journal of Thermal Engineering, 3, 1498-1504
  10. Cihan, E. (2014). Cooling performance investigation of a system with an organic Rankine cycle using waste heat sources. Journal of Thermal Science and Technology, 34, 101-109
  11. Wang, M., Wang, J., Zhao, Y., Zhao, P., Dai, Y. (2013). Thermodynamic analysis and optimization of a solar-driven regenerative organic Rankine cycle (ORC) based on flat-plate solar collectors. Applied Thermal Engineering, 50, 816-825
  12. Kai, Z., Mi, Z., Yabo, W., Zhili, S., Shengchun, L., Jinghong, N. (2015). Parametric optimization of low temperature ORC system. Energy Procedia, 75, 1596-1602
  13. Gao, W., Li, H., Xu, G., Quan, Y. (2014). Working fluid selection and preliminary design of a solar organic Rankine cycle system. Environmental Progress & Sustainable Energy, 34, 619–626