Dergiler / Journal of Thermal Engineering / 2021 / Cilt: 7 - Sayı: 3

AN ESTIMATION METHOD FOR GREENHOUSE TEMPERATURE UNDER THE INFLUENCE OF EVAPORATIVE COOLING SYSTEM

Sayfa
918–933
Yayın Tarihi
2022-10-18
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The results indicated that the inside air, the floor and the cover temperature of the greenhouse reduced by respectively 20.6, 13.0 and 20.6 oC when using the FP system with the air velocity of 4.4 ms-1 and the pad thickness of 6 cm.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Temperature is one of the most important plant growth parameters that should be controlled in the greenhouses.
📊
Temel Bulgular & Veri:Maximum deviations of 5.32, 5.56 and 4.53oC were observed between the theoretical and experimental temperatures of the inside air, the floor and the cover of the greenhouse without the cooling system, respectively.
💡
Sonuç & Katkı:The results indicated that the inside air, the floor and the cover temperature of the greenhouse reduced by respectively 20.6, 13.0 and 20.6 oC when using the FP system with the air velocity of 4.4 ms-1 and the pad thickness of 6 cm.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Absolute Error · Fan and Pad · Heat and Mass Transfer

Abstract

Temperature is one of the most important plant growth parameters that should be controlled in the greenhouses. The present study was aimed to assess the thermal behavior of a greenhouse with and without the fan and pad (FP) evaporative cooling system. A method was developed to approximate the greenhouse temperature based on the mass and energy balance equations. For this purpose, both of the fan and pad evaporative cooling system, and the greenhouse were studied. The results of the theoretical analysis were compared with those achieved by the experiments. Maximum deviations of 5.32, 5.56 and 4.53oC were observed between the theoretical and experimental temperatures of the inside air, the floor and the cover of the greenhouse without the cooling system, respectively. Whereas, the mean absolute error values associated with the predicted temperatures of the greenhouse with the FP system were ranged between 1.50 and 25.67%. Based on the obtained values for the correlation coefficient, root mean square error and mean absolute magnitude error, it was concluded that the models satisfactorily predicted the temperature of the greenhouse components. An air circulation system inside the greenhouse can be proposed to maintain the lumped condition even at the high temperatures, and lead to smaller errors. The results indicated that the inside air, the floor and the cover temperature of the greenhouse reduced by respectively 20.6, 13.0 and 20.6 oC when using the FP system with the air velocity of 4.4 ms-1 and the pad thickness of 6 cm.

🔖

Bu Makaleye Atıf Yap

Shojaei, M. H., Mortezapour, H., Jafarinaeimi, K., Maharlooei, M. M. (2022). AN ESTIMATION METHOD FOR GREENHOUSE TEMPERATURE UNDER THE INFLUENCE OF EVAPORATIVE COOLING SYSTEM. Journal of Thermal Engineering, Cilt: 7 - Sayı: 3, 918–933. https://ajindex.com/articles/566652

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Iosif Stylianou I, Tassou S, Christodoulides P, Panayides I, Florides G. Measurement and analysis of thermal properties of rocks for the compilation of geothermal maps of Cyprus. Renewable Energy 2016;88(Supplement C):418- 29.
  2. Mustafa Omer A. Ground-source heat pumps systems and applications. Renewable and Sustainable Energy Reviews 2008;12(2):344-71.
  3. Benli H. Performance prediction between horizontal and vertical source heat pump systems for greenhouse heating with the use of artificial neural networks. Heat Mass Transfer 2016;52(8):1707-24.
  4. Çakır U, Şahin E. Using solar greenhouses in cold climates and evaluating optimum type according to sizing, position and location: A case study. Comput Electron Agric 2015;117:245-57.
  5. Esmaeli H, Roshandel R. Optimal design for solar greenhouses based on climate conditions. Renewable Energy 2020;145:1255-65.
  6. Impron I, Hemming S, Bot GPA. Simple greenhouse climate model as a design tool for greenhouses in tropical lowland. Biosyst Eng 2007;98(1):79-89.
  7. Garcia-Alonso Y, Espi E, Salmeron A, Fontecha A, Gonzalez A, Lopez J, editors. New cool plastic films for greenhouse covering in tropical and subtropical areas2006: International Society for Horticultural Science (ISHS), Leuven, Belgium.
  8. Ould Khaoua SA, Bournet PE, Migeon C, Boulard T, Chassériaux G. Analysis of Greenhouse Ventilation Efficiency based on Computational Fluid Dynamics. Biosyst Eng 2006;95(1):83-98.
  9. Kumar K, Tiwari K, Jha MK. Design and technology for greenhouse cooling in tropical and subtropical regions: A review. Energy Build 2009;41(12):1269-75.
  10. Teitel M, Liran O, Tanny J, Barak M. Wind driven ventilation of a mono-span greenhouse with a rose crop and continuous screened side vents and its effect on flow patterns and microclimate. Biosyst Eng 2008;101(1):111-22.
  11. Ghoulem M, El Moueddeb K, Nehdi E, Boukhanouf R, Calautit JK. Greenhouse design and cooling technologies for sustainable food cultivation in hot climates: Review of current practi