Dergiler / Journal of Structural Engineering & Applied Mechanics (Online) / 2019 / Cilt: 2 - Sayı: 4

Seismic response of fixed-base and LRB base-isolated RC framesystems under NF and FF excitations

Sayfa
174–189
Yayın Tarihi
2022-10-19
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The results of the analysis showed that the effects of the NF earthquake record on the frame system had generally greater according to the effects of the FF earthquake records.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Seismic isolation systems can be used in new structures to reduce the negative effects of the earthquake on the building.
📊
Temel Bulgular & Veri:For this purpose, two-plane frame systems with 4 and 8 story were designed.
💡
Sonuç & Katkı:The results of the analysis showed that the effects of the NF earthquake record on the frame system had generally greater according to the effects of the FF earthquake records.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Seismic isolation systems can be used in new structures to reduce the negative effects of the earthquake on the building. The lead rubber bearing (LRB) is one of the most commonly used seismic isolators. This study focused on the behavior of Reinforced Concrete (RC) frame systems with fixed-base and Lead Rubber Bearing systems under Near-Fault (NF) and Far-Fault (FF) records. For this purpose, two-plane frame systems with 4 and 8 story were designed. Nonlinear behavior of both superstructure and isolation system was taken into consideration in modeling. The nonlinear time history analysis method was used in the seismic analysis of reinforced concrete frame systems. Finally, story acceleration, interstory drift ratio, base shear force and distribution of plastic hinges and their damage conditions were evaluated. The results of the analysis showed that the effects of the NF earthquake record on the frame system had generally greater according to the effects of the FF earthquake records.

🔖

Bu Makaleye Atıf Yap

KÖMÜR, M. A., ORUÇ, R., DENEME, İ. Ö. (2022). Seismic response of fixed-base and LRB base-isolated RC framesystems under NF and FF excitations. Journal of Structural Engineering & Applied Mechanics (Online), Cilt: 2 - Sayı: 4, 174–189. https://ajindex.com/articles/566398

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Tavakoli HR, Naghavi F, Goltabar AR (2014) Dynamic responses of the base-fixed and isolated building frames under far- and near-fault earthquakes. Arabian Journal for Science and Engineering 39(4): 2573–2585
  2. Makris N (2019) Seismic isolation: early history. Earthquake Engineering and Structural Dynamics 48(2): 269–283
  3. Malhotra PK (1999) Response of buildings to nearfield pulse-like ground motions. Earthquake Engineering and Structural Dynamics 28(11): 1309–1326
  4. MacRae GA, Morrow DV, Roeder CW (2002) Near-fault ground motion effects on simple structures. Journal of Structural Engineering 127(9): 996–1004
  5. Moniri H (2017) Evaluation of seismic performance of reinforced concrete (RC) buildings under near-field earthquakes. International Journal of Advanced Structural Engineering 9: 13–25
  6. Liao WI, Loh CH, Wan S (2001) Earthquake responses of RC moment frames subjected to nearfault ground motions. Structural Design of Tall Buildings 10(3): 219–229
  7. Kostinakis K, Athanatopoulou A, Morfidis K (2015) Correlation between ground motion intensity measures and seismic damage of 3D R/C buildings. Engineering Structures 82: 151–167
  8. Seo J, Hu JW, Davaajamts B (2015) Seismic performance evaluation of multistory reinforced concrete moment resisting frame structure with shear walls. Sustainability 7(10): 14287–14308
  9. Mazza M (2015) Effects of near-fault ground motions on the nonlinear behaviour of reinforced concrete framed buildings. Earthquake Science 28(4): 285–302
  10. Güneş N, Ulucan ZÇ (2019) Nonlinear dynamic response of a tall building to near-fault pulse-like ground motions. Bulletin of Earthquake Engineering 17: 2989–3013
  11. Rong Q (2019) Optimum parameters of a five-story building supported by lead-rubber bearings under near-fault ground motions. Journal of Low Frequency Noise, Vibration and Active Control 0(0): 1–16
  12. Jangid RS (2007) Optimum lead–rubber isolation bearings for near-fault motions. Engineering Structures 29: 2503–2513
  13. Providakis CP (2008) Effect of LRB isolators and supplemental viscous dampers on seismic isolated buildings under near-fault excitations. Engineering Structures 30: 1187–1198
  14. Noruzi F, Hasanpour A, Saeedian S (2017) Seismic Response Assessment of high-rise RC building with Lead Rubber bearing base isolator on different soil types. Journal of Civil Engineering Researchers 0: 1-9
  15. Komur MA, Karabork T, Deneme IO (2011) Nonlinear dynamic analysis of isolated and fixedb