Dergiler / Istanbul University Journal of Electrical and Electronics Engineering / 2011 / Cilt: 11 - Sayı: 1

Desıgnıng a wınd turbıne wıth permanent magnet synchronous machıne

Sayfa
1311–1317
Yayın Tarihi
2022-10-18
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In the last part of study, power quality is evaluated with the harmonic analysis and the total harmonic distortion of the system is in the range of IEC 61400-36 and IEEE 519-1992 Standards.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Abstract: In this study, wind energy that is one of the sources of clean and renewable energy is modeled for ©generating electrical energy by using PSIM .
📊
Temel Bulgular & Veri:E- 33 type (ENERCON) wind turbine data sheet is used for the modeling.
💡
Sonuç & Katkı:In the last part of study, power quality is evaluated with the harmonic analysis and the total harmonic distortion of the system is in the range of IEC 61400-36 and IEEE 519-1992 Standards.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Abstract: In this study, wind energy that is one of the sources of clean and renewable energy is modeled for ©generating electrical energy by using PSIM . E- 33 type (ENERCON) wind turbine data sheet is used for the modeling. Wind turbine system is chosen as variable speed instead of fixed one because of the advantage of generating more efficient and higher quality electrical energy. So the generator is connected to the power electronic circuit first and then the step-up transformer. Permanent magnet synchronous machine (PMSM) is chosen as a generator. An uncontrolled rectifier is modeled after the generator in the system and an inverter is also modeled at the grid side for generating electrical energy in the suitable form. Active and reactive power control is achieved by the grid side converter with the indirect current control. Synchronization with the grid is made by Phase Locked Loop(PLL). Both of the power converters are modeled and simulation results are presented. In the last part of study, power quality is evaluated with the harmonic analysis and the total harmonic distortion of the system is in the range of IEC 61400-36 and IEEE 519-1992 Standards.

🔖

Bu Makaleye Atıf Yap

ERGENE, L. T., TOPAL, M. (2022). Desıgnıng a wınd turbıne wıth permanent magnet synchronous machıne. Istanbul University Journal of Electrical and Electronics Engineering, Cilt: 11 - Sayı: 1, 1311–1317. https://ajindex.com/articles/543695

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (6)

  1. Iulian. M., Antoneta. B., Optimal Control of Wind Energy Systems, Springer, 2008
  2. Marques, J., Pinheiro, H., Grübdling, H.,Hey, L., "A Survey on Variable-Speed Wind Turbine System", Cientifico Greater Forum of Brazillian Electronics of Power, pp. 732-738, 2003
  3. Shuhui Li, Timothy A. Haskew, Ling Xu, "Conventional and Novel Control Designs for Direct Driven PMSG Wind Turbines", Electric Power Systems Research, pp. 328-338, 2010
  4. Lubosny, Z., Wind Turbine Operation in Electric Power Systems, Springer Press, 2003
  5. Daryoush, M., Javier, L., Marc., "Vector Control of PMSG for Grid-Connected Wind Turbine Applications", Aalborg University Spring Semester Project, 2009
  6. Yang Liyong, Yuan Peie, Chang Zhenguo, "A Novel Control Strategy of Power Converter Used to Direct Driven Permanent Magnet Wind Power Generation System", Electronics and Intelligent Transportation System, pp. 456-459, 2009.