⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Simulation results validate the dynamic behavior of Fuzzy logic controller over PI controller

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The paper presents the concept of wind power generation system inverter as SAF under balanced and unbalanced conditions.
📊
Temel Bulgular & Veri:The reference currents extract by the Fuzzy logic controller based instantaneous active and reactive power (p-q) strategy.
💡
Sonuç & Katkı:Simulation results validate the dynamic behavior of Fuzzy logic controller over PI controller
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

The paper presents the concept of wind power generation system inverter as SAF under balanced and unbalanced conditions. PV based systems are practically inactive during the night time, Because of the system cannot conserve the energy on the night time. During the night time, the PV-SAF provides only the compensation for the reactive power disturbance through the battery bank. The reference currents extract by the Fuzzy logic controller based instantaneous active and reactive power (p-q) strategy. When the supply voltages are balanced and sinusoidal, then all controllers converge to the same compensation characteristics. However, when the supply voltages are distorted and/or un-balanced sinusoidal, these control strategies result in different degrees of compensation in harmonics. The p-q control strategy with PI controller is unable to yield an adequate solution when source voltages are not ideal. Extensive simulations were carried out; simulations were performed with balance, unbalanced and non sinusoidal conditions. Simulation results validate the dynamic behavior of Fuzzy logic controller over PI controller

🔖

Bu Makaleye Atıf Yap

K, P., S, V., P, T., N, Y. (2022). HARMONIC CURRENT COMPENSATION IN SELF EXCITED INDUCTION GENERATOR USING ACTIVE FILTER. Istanbul University Journal of Electrical and Electronics Engineering, Cilt: 15 - Sayı: 1, 20–24. https://ajindex.com/articles/543641

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Wu, B., Lang, Y., Zargari, N., and Kouro, S, Power Conversion and Control of Wind Energy Systems, John Wiley & Sons, 2011
  2. Jose Luis D G., Oriol GB., Lluis T R., and Adria J F., “Indirect Vector Control of a Squirrel Cage induction generator wind turbine”, Computers and Mathematics with Applications, Elsevier, Vol:64, No: 2, pp. 102-114, 2012
  3. Roberto C., Ruben P., Jon C., and Patrick W., “Analytical and Experimental Evaluation of a WECS based on a cage Induction generator fed a Matrix Converter”, IEEE transactions on Energy Conversion, Vol:26, No:1, pp. 204-215, 2011
  4. Tolga S., and Eyup A., “Modeling of a 5kW WECS with induction generator and comparison with experimental results”, Renewable Energy Journal, Vol: 30, pp.913-929, 2005
  5. Gabriel C., and Stefan B., “Design and control strategies of an Induction machine based fly wheel energy storage system associated to a variable speed wind generator”, IEEE transactions on Energy Conversion, Vol: 25, No: 2, pp.526-534, 2010
  6. Blaabjerg F., Chen Z., Teodorescu R., and Lov F., “Power Electronics in Wind Turbine Systems”, Proceedings of International Conference on Power Electronics and Motion Control, Shanghai, China, pp. 1-11, 2006
  7. Vladislav A., Induction Generators for Wind Power, MultiScience Publishing Co. Ltd, UK, 2005
  8. Darwin R., Luis M., Juan D., and Jose E., “Improving passive filter compensation performance with active Techniques”, IEEE transactions on Industrial Electronics, Vol: 50, No: 1, pp. 161- 168, 2003
  9. Akagi H., Watanabe E. H., and Aredes M., Instantaneous Power Theory and Applications to Power Conditioning, Piscataway, NJ: IEEE Press, 2007
  10. Buso S., Malesani L., and Mattavelli P., “Comparison of current control techniques for Active Power Filter Applications”, IEEE transactions on Industrial Electronics, Vol: 45, No:5, pp. 722-729, 1998
  11. Tsengenes G., and Georgios A., “Shunt Active Power Filter Control Using Fuzzy Logic Controllers”, Proceedings of International Symposium on Industrial Electronics, Poland, pp 365-371, 2011
  12. Krause P.C., Wasynczuk O., and Sudhoff S.D., Analysis of Electric Machinery and Drive Systems, IEEE press, NewYork, 2002
  13. Mikko R., Mika S., and Heikki T., “Comparison of VoltageSource and Current-Source Shunt Active Power Filters”, IEEE Transactions on Power Electronics, Vol: 22, No: 2, pp. 636-643, 2007
  14. Carneiro H., Couto C., and Afonso, J.L., “Simulations of a current-source Shunt Active Power Filter with Carri