Amaç & Hipotez:Equations for ideal vapour compression heat pump coefficient of performance (COPR) which contain two fit-parameters are reported in this work.
📊
Temel Bulgular & Veri:The best equation gave error ≥5% over wide range of temperature-lift and for different working fluid types that include fluorocarbons, hydrocarbons and inorganic fluids.
💡
Sonuç & Katkı:In these respects the equation performs better than the one-parameter models reported earlier.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:themodynamics · heat pump
Abstract
Equations for ideal vapour compression heat pump coefficient of performance (COPR) which contain two fit-parameters are reported in this work. These equations contain either temperature term alone or temperature and pressure terms as the only thermodynamic variable(s). The best equation gave error ≥5% over wide range of temperature-lift and for different working fluid types that include fluorocarbons, hydrocarbons and inorganic fluids. In these respects the equation performs better than the one-parameter models reported earlier.
Anahtar kelimeler
🔖
Bu Makaleye Atıf Yap
OLAWALE, A. S., ADEFİLA, S. S. (2022). Two-parameter Rankine Heat Pumps’ COP Equations. International Journal of Thermodynamics, Cilt: 15 - Sayı: 2, 83–90. https://ajindex.com/articles/541880