Dergiler / Hacettepe Journal of Biology and Chemistry / 2012 / Cilt: 40 - Sayı: 4

Statistical analysis of blood cells and blood proteins behaviours contacted with PMEA-coated and uncoated oxygenators

PMEA-kaplı ve kapsız oksijenatörlerle temas eden kan hücrelerinin ve kan proteinlerinin davranışının istatistiksel analizi

Sayfa
445–455
Yayın Tarihi
2022-10-17
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bazı regrasyon modellerinde sadece etkileşim etkisi değişkenlerle birlikte görülmüştür ki bunun anlamı, Kaplanmış cardiopulmoner by pass filtreleri, kaplanmamışlar ile karşılaştırıldığında PMEA kaplılar protein adsorpsiyonu için daha hidrofilik yüzeyler oluşturmuştur.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Polimetoksietilen akrilat (PMEA) kaplı ve kapsız oyuk fiberlerin kan uyumluluğu multivariat istatistiksel yöntemler kullanılarak incelenmiştir.
📊
Temel Bulgular & Veri:Her iki grup da toplam bilirubin, direkt bilirubin, eritrosit, albumin, fibrinojen, lökosit ve toplam protein analiz sonuçları ile değerlendirilmiştir.
💡
Sonuç & Katkı:Bazı regrasyon modellerinde sadece etkileşim etkisi değişkenlerle birlikte görülmüştür ki bunun anlamı, Kaplanmış cardiopulmoner by pass filtreleri, kaplanmamışlar ile karşılaştırıldığında PMEA kaplılar protein adsorpsiyonu için daha hidrofilik yüzeyler oluşturmuştur.
🔬Tür:Deneysel Tarla Denemesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Polimetoksietilen akrilat (PMEA) kaplı ve kapsız oyuk fiberlerin kan uyumluluğu multivariat istatistiksel yöntemler kullanılarak incelenmiştir. Hastalar iki gruba ayrılmıştır: biri PMEA kaplı diğeri de kapsız oksijeneratör fiberlerleri kullanan hastalar. Her iki grup da toplam bilirubin, direkt bilirubin, eritrosit, albumin, fibrinojen, lökosit ve toplam protein analiz sonuçları ile değerlendirilmiştir. Karşılaştırma için üç düzey alınmıştır: taban seviyesi (T1), protamin enjeksiyonu sonrası (T4) ve yoğun bakım (T5). Düzeyler arasında belirgin farklılıklar gözlenmemiştir. Ek olarak ölçümler yaşa göre de karşılaştırılmıştır. Hastalar dört farklı yaş grubuna ayrılmıştır ve yoğun bakım fibrinojen değeri ve taban seviyesi protrombin zamanı (Pt) değeri hariç yaş grupları arasında bir fark bulunmamıştır. Sonra ölçümlerin önemli ilişki değerini bulmak için deneme yapıldı. Önemli bir tane bulunduktan sonra regrasyon modelinde, bir ölçüm bağımlı değişken olarak ve bağımlı değişkenle çok iyi bağlantı kuran ölçümler de bağımsız değişkenler olarak alınmıştır. Analizde kurulan modellerin hepsinin r2, p ve F değerleri önemlidir. Bazı regrasyon modellerinde sadece etkileşim etkisi değişkenlerle birlikte görülmüştür ki bunun anlamı, Kaplanmış cardiopulmoner by pass filtreleri, kaplanmamışlar ile karşılaştırıldığında PMEA kaplılar protein adsorpsiyonu için daha hidrofilik yüzeyler oluşturmuştur.

Abstract

The blood compatibility of the polymethoxyethyle acrylate (PMEA) coated and uncoated hollow fibers were investigated using multivariate statistical methods. The patients were divided into two groups where one is PMEA-coated fibers used patients and the other is uncoated oxygenator fibers used patients. The two groups were evaluated by total bilirubin, direct bilirubin, erythrocyte, albumin, fibrinogen, leukocyte, and total protein analysis results. Three evaluations were taken for comparison: baseline (T1), after protamine injection (T4) and intensive care (T5). There are no significant differences in the comparison. Additionally, the measurements were also compared by age. The patients were divided to four different age groups and no differences were found between the age groups except intensive care fibrinogen value and baseline protrombine time (Pt) Value. Then attempt were made to look for the significant correlation value of the measurements. After significant one was found, one measurement value was taken as dependent variable and the measurements, which are highly correlated with dependent variable as independent variables in the regression model. All of the models established that the analysis were significant with both squared r, p and F values. In some regression models, only interaction effect was seen with the variables, which means that PMEA-coating created more hydrophilic surfaces for protein adsorption when compared with uncoated Cardiopulmonary by pass filters.

🔖

Bu Makaleye Atıf Yap

AKPOLAT, O., KOCAKULAK, M., AYHAN, H., AYHAN, F. (2022). Statistical analysis of blood cells and blood proteins behaviours contacted with PMEA-coated and uncoated oxygenators. Hacettepe Journal of Biology and Chemistry, Cilt: 40 - Sayı: 4, 445–455. https://ajindex.com/articles/529203

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (17)

  1. B.G. Tabachick, L.S. Fidell, Using Multivariate Statistics, Fourth Edition, Northridge: Harper Collins, (2001)
  2. A.L. Edwards (Translated by Selim Hovardaoğlu) (1995), Entering to Linear Regression and Correlation, Hatipoğlu press
  3. P. Newbold, (translated by Ümit Şenesen) (2001), Statistics for Economy and Science of Business, Second Eddition, Literature press
  4. Boehm et al., Premixed insulin aspart 30 vs. premixed human insulin 30/70 twice daily: a randomized trial in Type 1 and Type 2 diabetic patients, Diabetes UK, Diabetic Medicine, (2002) 393
  5. Christophe Baufreton et al., A combined approach for improving cardiopulmonary bypass in coronary artery surgery: a pilot study, Perfusion, (2002) 407
  6. B.G. Tabachick, L.S. Fidell, Using Multivariate Statistics, Fourth Edition, Northridge: Harper Collins, (2001)
  7. A.L. Edwards (Translated by Selim Hovardaoğlu), Entering to Linear Regression and Corelation, Hatipoğlu press, (1995)
  8. P. Newbold (translated by Ümit Şenesen), Statistics for Economy and Science of Business, Second Eddition, Literature press, (2001)
  9. Boehm et al., Premixed insulin aspart 30 vs. premixed human insulin 30/70 twice daily: a randomized trial in Type 1 and Type 2 diabetic patients, Diabetes UK, Diabetic Medicine, (2002) 393
  10. Christophe Baufreton et al., A combined approach for improving cardiopulmonary bypass in coronary artery surgery: a pilot study, Perfusion, (2002) 407
  11. H.l. Lazar, X. Zhang, T. Hamasaki, C.A. Memmelo, P. Treanor, S. Rivers, G.S. Aldea, S.A. Bernard, R.J. Shemin, Annual Thorac Surgery, 63 (1997) 1701
  12. H. Guckenberger, B. Hacker, T. Hartman, T. Scheybani, Z. Wang, W. Wiegrabe, W. Baumeister, J. Vac. Sci. Technol., B 9 (1991) 1227
  13. R.J. Leatherbarrow, M. Stedman, T.N.C. Wells, J. Mol. Biol., 22 (1991) 361
  14. N. Saito, S. Motoyama, J. Sawamoto, International Society for Artificial Organs, 24 (2000) 547
  15. F. Ayhan, A. Yousefirad, H. Ayhan, Biocompatibility Investigation and Urea Removal from blood by Urease Immobilized HEMA Incorporated Poly(Ethylenglycoldi metacrylate) microbeads, App. Biomat. Sec. J. Biomed. Mat. Res., 64B (2003) 13
  16. M. Kocakulak, S. Günaydın, R. Saber, B. Farsak, N. Bingöl, C. Koçum, T. Sarı, Y. Zorlutuna, H. Ayhan, E. Pişkin, Investigation of Blood Proteins Adsorption on Coated And Uncoated Hollow Fiber Surfaces in Extracorporeal Circuits During Cardiopulmonary Bypass, The International Symposium of IEEE, 15-18 October 2001, İstanbul, Turkey
  17. M. Koca