Dergiler / Gazi Medical Journal / 2010 / Cilt: 21 - Sayı: 1

Comparison of blood pool gated spect with three different gated myocardial perfusion spect programs for left ventricular functional parameters in patients with low likelihood for cad

Koroner arter hastalığı riski düşük olan hastalarda sol ventrikül fonksiyonlarının değerlendirilmesinde gated kan havuzu spect programının karşılaştırılması

Sayfa
28–33
Yayın Tarihi
2022-10-19
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Tüm gMPS programları BPGS ile iyi korele olup 4D-MSPECT programcı en iyi korelasyonu gösterdi.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Bu çalışmanın amacı koroner arter hastalığı (KAH) riski düşük olan hastalarda sol ventrikülün fonksiyonel parametrelerini belirlemede farklı gated miyolcardiyal perftizyon SPECT (gMPS) programlarını gated kan havuzu SPECT (BPGS) ile karşılaştırmaktı.
📊
Temel Bulgular & Veri:Ayrıca kalp boyutunun fonksiyonel parametreler üzerine etkisini araştırmaktı.
💡
Sonuç & Katkı:Bulgular: Tüm gMPS programları BPGS ile iyi korele olup 4D-MSPECT programcı en iyi korelasyonu gösterdi.
🔬Tür:Laboratuvar & Saha Deneyi
📍Kapsam:40 hasta
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Bu çalışmanın amacı koroner arter hastalığı (KAH) riski düşük olan hastalarda sol ventrikülün fonksiyonel parametrelerini belirlemede farklı gated miyolcardiyal perftizyon SPECT (gMPS) programlarını gated kan havuzu SPECT (BPGS) ile karşılaştırmaktı. Ayrıca kalp boyutunun fonksiyonel parametreler üzerine etkisini araştırmaktı. Gereç ve Yöntem : KAH riski diisük olan ve gMPS incelemesi normal olarak değerlendirilen 40 hastaya gMPS incelemesini takip eden 3 gün içinde istirahat kan havuzu görüntülemesi yapıldı. 3 farklı gMPS programına (Emory Cardiac Toolbox (ECT), Quantitative Gated SPECT (QGS) and 4DMSPECT) ait sonuçlar BPGS referans alınarak değerlendirildi ve tüm programlar birbiri ile karşılaştırıldı. Ayrıca hastalar sistol-sonu hacimlerine (SSH) göre gruplandı; SSH 30 mi olan hastalar (grup 2) ile fonksiyonel parametreler açısından karşılaştırıldı. Karşılaştırmada tekrarlayan ANOVA ölçümü, doğrusal regresyon analizi ve Bland-Altman metodu ile yapıldı. Bulgular: Tüm gMPS programları BPGS ile iyi korele olup 4D-MSPECT programcı en iyi korelasyonu gösterdi. ECT dışında diğer gMPS programları ile BPGS arasındaki ortalama EF farkı istatistiksel olarak anlamlı bulunmadı. ECT programı ile ise belirgin yüksek ejeksiyon fraksiyonu (EF) değerleri hesaplandı. BPGS ve gMPS programlan arasında ortalama diyastol sonu hacmi (DSH) değerleri açısından istatistiksel farklılık saptanmamıs olup, ECT ve 4D-MSPECT ile hesaplanan ortalama SSH değerleri BPGS'den anlamlı derecede düşüktü. Tüm programlar ile küçük hacimli kalplerde EF değerleri istatiksel olarak anlamlı ölçüde yüksek olarak hesaplandı ve BPGS yöntemine en yakın sonuçlar grup 1 de 4D-MSPECT ile grup 2 de ise QGS ile bulundu. Sonuç: Sol ventrikül fonksiyonlarını belirlemede gMPS programları ve BPGS iyi korele ve uyumludur. Tüm hasta grubunda ve küçük kalpli hasta grubunda referans yönteme en yakın sonuçlar 4D-MSPECT ile hesaplandı. Küçük kalplerde EF değerlerinin olduğundan yüksek hesaplanması gMPS programlarının yanında ERNA ve BPGS için de önemli bir problemdir. Bu çalışmada küçük kalplerde cn düşük EF değerleri QGS ile hesaplandı.

Abstract

Purpose: To compare several gated myocardial perfusion SPECT (gMPS) programs with blood pool gated SPECT (BPGS) for the evaluation of left ventricular (LV) functional parameters and further investigate the effect of heart size in a population with low coronary artery disease (CAD) risk. Materials and Methods: Forty patients whose gMPS were seen to be normal were included. Rest blood pool studies were performed in patients 3 days after the evaluation of gMPS, and the data were processed with 3 different programs: Emory Cardiac Toolbox (ECT), Quantitative Gated SPECT (QGS), and 4D-MSPECT. The results of each program were evaluated using BPGS as the reference method and all programs were compared with each other. Patients were also grouped according to their end systolic volumes (ESV) with BPGS; the ESV 30 ml) for functional parameters. Repeated measures ANO- VA, linear regression, and Bland-Altman analysis were used to compare the methods. Results: All gMPS programs were well correlated with BPGS, while 4D-MSPECT had fee best correlation. Mean differences in EF between gMPS programs and BPGS were not significant, except for ECTb, with which EF values were significantly higher from BPGS. No statistically significant differences were observed between BPGS and gMPS programs for mean end diastolic volume (EDV) values. However, ESV values from ECT and 4D M SPECT' programs were significantly lower than those from BPGS. EF values were significantly higher in patients with small hearts for all methods. The closest EF values to the reference method values were calculated with 4D MSPECT in group 1 and with QGS in group 2. Conclusion: gMPS programs yield accurate and reliable results in the assessment of myocardial function in addition to myocardial perfusion. In all patient groups and the small heart group, the closest LVEF values to those of the reference method were calculated with 4D-MSPECT. Overestimation of LVEF in small hearts isjhe major problem of gMPS methods and also ERNA and BPGS. In this study the lowest overestimations of LVEF values were obtained with QGS in small hearts.

🔖

Bu Makaleye Atıf Yap

ÜNLÜ, M., AKDEMİR, Ü. Ö., POYRAZ, N. Y., ÖZDEMİR, E. (2022). Comparison of blood pool gated spect with three different gated myocardial perfusion spect programs for left ventricular functional parameters in patients with low likelihood for cad. Gazi Medical Journal, Cilt: 21 - Sayı: 1, 28–33. https://ajindex.com/articles/520243

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. 1 Faber TL, Cooke CD, Folks RD, et al. Left ventricular function and perfusion from gated SPECT perfusion images: an integrated method. J Nucl Med. 1999 Apr;40:650-9. 2. Germano G, Kiat H, Kavanagh PB, et al. Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. J Nucl Med. 1995 Nov;36:2138-47. 3. Ficaro EP, Quaife RA, Kritzman JN, et al. Accuracy and reproducibility of 3D-MSPECT for estimating left ventricular ejection fraction in patients with severe perfusion abnormalities (abstract). Circulation 1999; 100: 126. 4. DePuey EG, Nichols K, Dobrinsky C. Left ventricular ejection fraction assessed from gated technetium-99m- sestamibi SPECT. J Nucl Med. 1993 Nov;34:1871-6. 5. Nichols K, DePuey EG, Rozanski A. Automation of gated tomographic left ventricular ejection fraction. J Nucl Cardiol. 1996 Nov-Dec;3:475-82. 6. Hambye AS, Dobbeleir A, Vervaet A, et al. Can we rely on 99Tcm-sestamibi gated tomographic myocardial perfusion imaging to quantify left ventricular function? A comparative study with classical isotopic techniques for the measurement of ejection fraction. Nucl Med Commun. 1997 Aug; 18:751- 60. 7. Nichols K, Lefkowitz D, Faber T, et al. Echocardiographic validation of gated SPECT ventricular function measurements. J Nucl Med. 2000 Aug;41:1308-14. 8. Faber TL, Vansant JP, Pettigrew RI, et al. Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods. L Nucl Cardiol 2001; 8:645-651 9. Nakajima K, Higuchi T, Taki J, et al. Accuracy of ventricular volume and ejection fraction measured by gated myocardial SPECT: comparison of 4 software programs. J Nucl Med. 2001 Oct;42:1571-8. 10. Lipke CS, Kühl HP, Nowak B, et al. Validation of 4D-MSPECT and QGS for quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPET: comparison with cardiac magnetic resonance imaging. Eur J Nucl Med Mol Imaging. 2004 Apr;31:482-90. 11. Schaefer WM, Lipke CS, Standke D, et al. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D-MSPECT. J Nucl Med. 2005 Aug;46:1256-63. 12. Nakajima K, Taki J, Higuchi T, et al. Gated SPET quantification of small hearts: mathematical simulation and clinical application. Eur J Nucl Med. 2000 Sep;27(9): 1372-9. Erra¬tum in: Eur J Nucl Med 2000 Dec;27:1869. 13.