Heat Loss and Exergy Flow through Respiration of the Human Body under Different Meteorological Conditions

Sayfa
45–51
Yayın Tarihi
2022-10-12
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

For a human body engaging in light activity in a hot climate zone, the exhaled air temperature, specific humidity and relative humidity values were determined as 35.11 oC, 0.0333 kg H2O/kg dry air and 91.3%, respectively.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this study, monthly total heat loss (evaporative and convective heat losses) and exergy flow that occur as a result of respiration were determined for human bodies in states of light and heavy activity levels, and comparisons of the results obtained were made according to different meteorological conditions and regions.
📊
Temel Bulgular & Veri:For this purpose, seven different climate zones (CZ-1, CZ-2, CZ-3, CZ-4, CZ-5, CZ-6 and CZ-7) in Turkey were selected.
💡
Sonuç & Katkı:For a human body engaging in light activity in a hot climate zone, the exhaled air temperature, specific humidity and relative humidity values were determined as 35.11 oC, 0.0333 kg H2O/kg dry air and 91.3%, respectively.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Climate zone · Environmental differences · Exergy flow

Abstract

In this study, monthly total heat loss (evaporative and convective heat losses) and exergy flow that occur as a result of respiration were determined for human bodies in states of light and heavy activity levels, and comparisons of the results obtained were made according to different meteorological conditions and regions. For this purpose, seven different climate zones (CZ-1, CZ-2, CZ-3, CZ-4, CZ-5, CZ-6 and CZ-7) in Turkey were selected. Meteorological parameters such as atmospheric temperature, atmospheric pressure and relative humidity were used for energy and exergy analyses. According to the obtained results, total heat loss and exergy flow through respiration of the human body demonstrated considerable variations seasonally depending on the climate zones. The highest heat loss and exergy flow values were determined in the region of Continental climate (CZ-2), while the lowest heat loss and exergy flow values were obtained in the region of Mediterranean climate (CZ-5). For a human body engaging in light activity in a hot climate zone, the exhaled air temperature, specific humidity and relative humidity values were determined as 35.11 oC, 0.0333 kg H2O/kg dry air and 91.3%, respectively.

🔖

Bu Makaleye Atıf Yap

ŞİMŞEK, E., ŞAHİN, B., ÖZBEK, A., YAŞAR, A., BİLGİLİ, M. (2022). Heat Loss and Exergy Flow through Respiration of the Human Body under Different Meteorological Conditions. European Mechanical Science, Cilt: 3 - Sayı: 2, 45–51. https://ajindex.com/articles/512473

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (3)

  1. Parsons K. (2002). Human Thermal Environments. CRS Press, third ed. Taylor & Francis Group, New York. ASHRAE, Handbook Fundamentals (1993) American Society of Physiology and Human Environment. Inc, Atlanta, USA. Licina, D., Melikov, A.K., Sekhar, C., Tham, K.W. (2015). Air temperature investigation microenvironment around a human body. Building and Environment, 92: 39-47, DOI: 10.1016/j.buildenv.2015.04.014. Caliskan, H. (2013). Energetic and exergetic comparison of the human body for the summer season. Energy Conversion and Management, 76: 169-176, DOI:10.1016/j.enconman.2013.07.045. Mady, CEK., Ferreira, M.S., Yanagihara, J.I., Saldiva, P.H.N., Junior, S.O. (2012). Modeling the exergy behavior of human body. Energy, 45: 546-553, DOI: 10.1016/j.energy.2012.02.064. Wang, F., Zhang, C., Lu, Y. (2015). Correction of the heat loss method for calculating clothing real evaporative resistance. Journal of Thermal Biology, 52: 45-51, DOI:10.1016/j.jtherbio.2015.05.004. Thellier, F., Monchoux, F., Spagnol, S., Sassi, M.B. (2009). Measurement of ambient air temperature for evaluation of human heat convective losses. Measurement, 42: 62-70, DOI: 10.1016/j.measurement.2008.04.001. Li, C., Ito, K. (2014). Numerical and experimental estimation of convective heat transfer coefficient of human body under strong forced convective flow. Journal of Wind Engineering & Industrial Aerodynamics, 126: 107-117, DOI: 10.1016/j.jweia.2014.01.003. White, M.D., Cabanac, M., (1995). Respiratory heat loss and core temperatures during submaximal exercise. Journal of Thermal Biology, 20: 489-496, DOI:10.1016/0306-4565(95)00011-K. Wu, X., Zhaoa, J., Olesen, B.W., Fang, L. (2013). A novel human body exergy consumption formula to determine indoor thermal conditions for optimal human performance in office buildings. Energy and Buildings, 56: 48–55, DOI:10.1016/j.enbuild.2012.10.010. Celik, N., Bayazit, Y. (2008). The effect of individual differences on thermo-regulation in human body simulations. Journal of Thermal Science and Technology, 28: 17-22.
  2. Ferreira, M.S., Yanagihara, J.I. (2009). A transient three-dimensional heat transfer model of the human body. International Communications in Heat and Mass Transfer, 36: 718-24, DOI: 10.1016/j.icheatmasstransfer.2009.03.010. Gebremedhin, K.G., Wu, B. (2002). Simulation of sensible and latent heat losses from wet-skin surface and fur layer. Journal of Thermal Biology, 27: 291-297, DOI: 10.1016/S0306-4565(01)00091-2.
  3. Mady, C.E.K., Albuquerque, C., F