⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

When thecut-off value for CLI was taken as 1.67, it was observed that PTX was predicted with 70% sensitivity and 62% specificity.Conclusion: The operator can predict the PTX in the patient by measuring the length of the clavicle and the BMI.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: Pneumothorax (PTX) is a complication that occurs while placing cardiac implantable electronic devices (CIED) in thethorax.
📊
Temel Bulgular & Veri:We aim to investigate whether there is a relationship between PTX and anatomic structure in patients with CIED.Methods: We retrospectively included 1602 patients in whom CIED had been placed for any reason between June 2008 and June2018.
💡
Sonuç & Katkı:When thecut-off value for CLI was taken as 1.67, it was observed that PTX was predicted with 70% sensitivity and 62% specificity.Conclusion: The operator can predict the PTX in the patient by measuring the length of the clavicle and the BMI.
🔬Tür:Araştırma Makalesi
📍Kapsam:2008 Verileri
⚙️Değişkenler:Alan Parametreleri

Abstract

Objective: Pneumothorax (PTX) is a complication that occurs while placing cardiac implantable electronic devices (CIED) in thethorax. In the literature, no clear relationship has been identified between the patient’s anatomic structure and the occurrence ofPTX. We aim to investigate whether there is a relationship between PTX and anatomic structure in patients with CIED.Methods: We retrospectively included 1602 patients in whom CIED had been placed for any reason between June 2008 and June2018. The proximal clavicle tip, middle point, distal tip, and angulus mandible were marked and distances between these pointswere measured. The ratio between body mass index (BMI) and clavicle length was obtained (clavicle length index).Results: We included 1568 (97.8%) patients without PTX and 34 (2.2%) patients with PTX in our study. The length of the clavicleand the distance between angulus mandible and clavicle middle point, angulus mandible, and clavicle distal tip significantlydecreased, while the clavicle length index (CLI) significantly increased in PTX patients. The distance between angulus mandibleand clavicle distal tip (OR: 0.811) and CLI (OR: 8.014) were determined to be independent predictors for pneumothorax. When thecut-off value for CLI was taken as 1.67, it was observed that PTX was predicted with 70% sensitivity and 62% specificity.Conclusion: The operator can predict the PTX in the patient by measuring the length of the clavicle and the BMI.

🔖

Bu Makaleye Atıf Yap

DEMİRTAŞ, A. O., İÇEN, Y. K., DÖNMEZ, E., ÖZSOY, İ. E., KOCA, H., KARATAŞ, F., KOÇ, M. (2022). A New Predictor for Patients with Cardiac Implantable Electronic Device in Iatrogenic Pneumothorax: The Clavicle Length Index. European Journal of Therapeutics, Cilt: 25 - Sayı: 3, 211–215. https://ajindex.com/articles/512266

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, et al. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Eur Heart J 2013; 34: 2281-329. [CrossRef] 2. Van der Heijden AC, Borleff CJ, Buiten MS, Thijssen J, van Rees JB, Cannegieter SC, et al. The clinical course of patients with implantable defirillators: Extended experience on clinical outcome, device replacements, and device-related complications. Heart Rhythm 2015; 12: 1169-76. [CrossRef] 3. Poole JE, Gleva MJ, Mela T, Chung MK, Uslan DZ, Borge R, at al. Complication rates associated with pacemaker or implantable cardioverter-defirillator generator replacements and upgrade procedures: results from the REPLACE registry. Circulation 2010; 122: 1553-61. [CrossRef] 4. Kirkfeldt RE, Johansen JB, Nohr EA, Moller M, Arnsbo P, Nielsen JC. Pneumothorax in cardiac pacing: a population-based cohort study of 28,860 Danish patients. Europace 2012; 14: 1132-8. [CrossRef] 5. Ogunbayo GO, Charnigo R, Darrat Y, Morales G, Kotter J, Olorunfemi O, et al. Incidence, predictors, and outcomes associated with pneumothorax during cardiac electronic device implantation: A 16-year review in over 3.7 million patients. Heart Rhythm 2017; 14: 1764-70. [CrossRef] 6. Van Rees JB, de Bie MK, Thijssen J, Borleff CJ, Schalij MJ, van Erven L. Implantation-related complications of implantable cardioverterd firillators and cardiac resynchronization therapy devices: A systematic review of randomized clinical trials. J Am Coll Cardiol 2011; 58: 995-1000. [CrossRef] 7. Chauhan A, Grace AA, Newell SA, Stone DL, Shapiro LM, Schofild PM, et al. Early complications after dual chamber versus single chamber pacemaker implantation. Pacing Clin Electrophysiol 1994; 17: 2012-5. [CrossRef] 8. Huang TW, Cheng YL, Tzao C, Hung C, Hsu HH, Chen JC, et al. Factors related to primary bilateral spontaneous pneumothorax. Thorac Cardiovasc Surg 2007; 55: 310-2. [CrossRef] 9. Chiu CY, Chen TP, Wang CJ, Tsai MH, Wong KS. Factors associated with proceeding to surgical intervention and recurrence of primary spontaneous pneumothorax in adolescent patients. Eur J Pediatr 2014; 173: 1483-90. [CrossRef] 10. Byrd CL. Clinical experience with the extrathoracic introducer insertion technique. Pacing Clin Electrophysiol 1993; 1