Dergiler / Eurasian Journal of Medical Investigation / 2022 / Cilt: 6 - Sayı: 1

An Effective Method for Intramedullary Fixation of Long Bone Fractures Reducing the Operative Duration and Flouroscopy Time: Guide Wire Assisted Nail Locking

Sayfa
38–44
Yayın Tarihi
2022-10-12
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Results: GAL technique compared to FHL technique was provided statistically significant reduction in operative duration of both femur fractre surgery (75 vs 93 min., p

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: Intramedullary nailing is still the gold standard surgical technique in treatment of long bone diaphyseal fractures.
📊
Temel Bulgular & Veri:In this surcigal procedure, distal locking phase gives rise to increased operative durations and flouroscopy time.
💡
Sonuç & Katkı:Results: GAL technique compared to FHL technique was provided statistically significant reduction in operative duration of both femur fractre surgery (75 vs 93 min., p
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Objectives: Intramedullary nailing is still the gold standard surgical technique in treatment of long bone diaphyseal fractures. In this surcigal procedure, distal locking phase gives rise to increased operative durations and flouroscopy time. Various device and techniques has been developed to overcome this issue. In our study, we aimed to investigate a practical and inexpensive technique for insertion of distal locking screws in intramedullary nailing of long bone diaphyseal fractures. Methods: 90 patients with diaphyseal fractures of tibia(48) and femur(42) who underwent intramedullary nailing were enrolled for this study. Classical Free Hand Locking (FHL) and Guidewire Assisted Locking (GAL) techniques were performed in distal locking phase of the procedure on 51 and 39 cases, respectively. These techniques were compared according to the influence on total operative duration and c-arm flouroscopy time. Results: GAL technique compared to FHL technique was provided statistically significant reduction in operative duration of both femur fractre surgery (75 vs 93 min., p

🔖

Bu Makaleye Atıf Yap

BARİS, A. (2022). An Effective Method for Intramedullary Fixation of Long Bone Fractures Reducing the Operative Duration and Flouroscopy Time: Guide Wire Assisted Nail Locking. Eurasian Journal of Medical Investigation, Cilt: 6 - Sayı: 1, 38–44. https://ajindex.com/articles/508522

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Alemdaroğlu KB, İltar S, Ozturk A, Gültaç E, Yücens M, Aydoğan NH. The role of biplanar distal locking in intramedullary nailing of tibial shaft fractures. Arch Bone Jt Surg 2019;7:33–7
  2. Han B, Shi Z, Fu Y, Ye Y, Jing J, Li J. Comparison of free-hand fluoroscopic guidance and electromagnetic navigation in distal locking of femoral intramedullary nails. Medicine (Baltimore) 2017;96:e7450
  3. Weidert S, Wang L, Landes J, Sandner P, Suero EM, Navab N, et al. Video-augmented fluoroscopy for distal interlocking of intramedullary nails decreased radiation exposure and surgical time in a bovine cadaveric setting. Int J Med Robot 2019;15:e1995
  4. Finelli CA, Ziran BH, Torini AP, Fernandes HJA, Dos Reis FB. Interlocking screws placed with freehand technique and uniplanar image intensification: the “dip-stick” technique. Injury 2014;45:S21–S5
  5. Arlettaz Y, Dominguez A, Farron A, Ehlinger M, Moor BK. Distal locking of femoral nails: evaluation of a new radiation-independent targeting system. J Orthop Trauma 2012;26:633–7
  6. Antonini G, Stuflesser W, Crippa C, Touloupakis G. A distal-lock electromagnetic targeting device for intramedullary nailing: Suggestions and clinical experience. Chin J Traumatol 2016;19:358–61
  7. Ode M, Mancha D, Ozoilo K, Amupitan I, Taiwo F, Onche I. Interlocking nail screw targeting with the sign interlocking system. JDMS 2015;14:29–31
  8. Chan DS, Burris RB, Erdogan M, Sagi HC. The insertion of intramedullary nail locking screws without fluoroscopy: a faster and safer technique. J Orthop Trauma 2013;27:363–6
  9. Ehlinger M, Dillman G, Czekaj J, Adam P, Taglang G, Brinkert D, et al. Distal targeting device for long Gamma nail(®). Monocentric observational study. Orthop Traumatol Surg Res 2013;99:799–804
  10. Choi J, Kim J, Hwang JY, Je M, Kim J-Y, Kim S-Y. A novel smart navigation system for intramedullary nailing in orthopedic surgery. Plos One 2017;12:e0174407
  11. Hsu WE, Yu CH, Chang CJ, Wu HK, Yu TH, Tseng CS. C-Arm imagebased surgical path planning method for distal locking of intramedullary nails. Appl Bionics Biomech 2018;2018:4530386
  12. Çelik H, Kara A, Sağlam Y, Türkmen İ, Aykut S, Erdil M. Can double fluoroscopy in the oblique position reduce surgical time and radiation exposure during intertrochanteric femur fracture nailing? Ulus Travma Acil Cerrahi Derg 2018;24:581–6
  13. Nwagbara I. Locked intramedullary nailing using the sign nailing device. Niger J Clin Pract 2019;22:485
  14. Barrick EF. Distal locking screw inse