Dergiler / Eurasian Journal of Emergency Medicine / 2018 / Cilt: 17 - Sayı: 4

Does Accelerometer Use Lead to Higher Quality CPR for Advanced Cardiac Life Support Providers? A Prospective Randomized Study

Sayfa
153–158
Yayın Tarihi
2022-10-11
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The primary outcome was mean compression rate, whereas the secondary outcomes included percent appropriate compression rate, mean compression depth, percent appropriate compression depth, percent complete chest recoil, percent chest compression fraction (CCF%), mean ventilations per minute.Results: The intervention arm had a higher median percent of compressions with an appropriate rate (between 100 and 120 min−1, 92.5% vs. 46.0%; p

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Aim: High-quality cardiopulmonary resuscitation (CPR) is the cornerstone to improved outcomes for patients with cardiac arrest.
📊
Temel Bulgular & Veri:Participants were tested on a high-fidelity manikin in a simulated cardiac arrest scenario performing 2 min of single-rescuer CPR.
💡
Sonuç & Katkı:The primary outcome was mean compression rate, whereas the secondary outcomes included percent appropriate compression rate, mean compression depth, percent appropriate compression depth, percent complete chest recoil, percent chest compression fraction (CCF%), mean ventilations per minute.Results: The intervention arm had a higher median percent of compressions with an appropriate rate (between 100 and 120 min−1, 92.5% vs. 46.0%; p
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Aim: High-quality cardiopulmonary resuscitation (CPR) is the cornerstone to improved outcomes for patients with cardiac arrest. The aim of this prospective randomized study was to evaluate whether audio-visual feedback use affects the critical components of high-quality CPR compared with CPR without feedback.Materials and Methods: One hundred in-hospital Advanced Cardiac Life Support (ACLS) providers volunteered as participants. Participants were tested on a high-fidelity manikin in a simulated cardiac arrest scenario performing 2 min of single-rescuer CPR. The control group completed the scenario with conventional CPR, whereas the intervention group adjusted CPR as instructed by the Philips MRx accelerometer. The primary outcome was mean compression rate, whereas the secondary outcomes included percent appropriate compression rate, mean compression depth, percent appropriate compression depth, percent complete chest recoil, percent chest compression fraction (CCF%), mean ventilations per minute.Results: The intervention arm had a higher median percent of compressions with an appropriate rate (between 100 and 120 min−1, 92.5% vs. 46.0%; p

🔖

Bu Makaleye Atıf Yap

KORNEGAY, J. G., FOERSTER, N. V., LAURIE, A., DAYA, M. (2022). Does Accelerometer Use Lead to Higher Quality CPR for Advanced Cardiac Life Support Providers? A Prospective Randomized Study. Eurasian Journal of Emergency Medicine, Cilt: 17 - Sayı: 4, 153–158. https://ajindex.com/articles/508068

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Mozaffarian D, Benjamin EJ, Go AS, Arnett DK, Blaha MJ, Cushman M, de Ferranti S, et al. Heart Disease and Stroke Statistics-2015 Update: A Report from the American Heart Association. Circulation. 2015
  2. [CrossRef] Wik L, Kramer-Johansen J, Myklebust H, Sorebo H, Svensson L, Fellows B, et al. Quality of cardiopulmonary resuscitation during out-of-hospital cardiac arrest. JAMA. 2005
  3. [CrossRef] Meaney PA, Bobrow BJ, Mancini ME, Christenson J, de Caen AR, Bhanji F, et al. Cardiopulmonary Resuscitation Quality: Improving Cardiac Resuscitation Outcomes both Inside and Outside the Hospital: A consensus Statement from the American Heart Association. Circulation. 2013
  4. [CrossRef] Abella BS, Sandbo N, Vassilatos P, Alvarado JP, O'Hearn N, Wigder HN, et al. Chest compression rates during cardiopulmonary resuscitation are suboptimal: a prospective study during in-hospital cardiac arrest. Circulation. 2005
  5. [CrossRef] Halperin HR, Tsitlik JE, Guerci AD, Mellits ED, Levin HR, Shi AY, et al. Determinants of blood flow to vital organs during cardiopulmonary resuscitation in dogs. Circulation. 1986
  6. [CrossRef] Niemann JT, Rosborough JP, Ung S, Criley JM. Coronary perfusion pressure during experimental cardiopulmonary resuscitation. Ann Emerg Med. 1982
  7. [CrossRef] Paradis NA, Martin GB, Rivers, EP, Goetting MG, Appleton TJ, Feingold M, et al. Coronary perfusion pressure and the return of spontaneous circulation in human cardiopulmonary resuscitation. JAMA. 1990
  8. [CrossRef] Sanders AB, Ogle M, Ewy GA. Coronary perfusion pressure during cardiopulmonary resuscitation. Am J Emerg Med. 1985
  9. [CrossRef] Neumar RW, Shuster M, Callawayn CW, Gent LM, Atkins DL, Bhanji F, et al. Part 1: Executive Summary: 2015 American Heart Association Guidelines Update for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care. Circulation. 2015
  10. [CrossRef] Skorning M, Beckers SK, Brokmann JC, Rortgen D, Bergrath S, Veiser T, et al. New visual feedback device improves performance of chest compressions by professionals in simulated cardiac arrest. Resuscitation. 2010
  11. [CrossRef] Havel C, Schreiber W, Trimmel H, Malzer R, Haugk M, Richling N, et al. Quality of closed chest compression on a manikin in ambulance vehicles and flying helicopters with a real time automated feedback. Resuscitation. 2010
  12. [CrossRef] Krasteval V, Jekova I, Didon JP. An audiovisual fee