⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

After the first hour of treatment, DMG had lower mean COHb (mg/dL) levels (9.6±5.0 vs. 12.8±6.2, p=0.0203) and higher mean PaO2 levels (224.4±56.5 vs. 183.4±63.7, p=0.0046) than SMG.Conclusion: Diffuser mask (DMG) appears to be better than simple face mask (SMG) in the first hour of treatment of CO intoxication.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Aim: In patients who do not have any indication for hyperbaric oxygen (O2) treatment, the main treatment to eliminate carbon monoxide (CO) is by giving O2 using a face mask.
📊
Temel Bulgular & Veri:To study the ability of DMG and SMG in lowering carboxyhemoglobin (COHb) levels after the first hour of O2 treatment in patients with CO intoxication.Materials and Methods: This was a prospective randomized clinical study conducted in patients aged ≥16 years old who were diagnosed with CO intoxi-cation.
💡
Sonuç & Katkı:After the first hour of treatment, DMG had lower mean COHb (mg/dL) levels (9.6±5.0 vs. 12.8±6.2, p=0.0203) and higher mean PaO2 levels (224.4±56.5 vs. 183.4±63.7, p=0.0046) than SMG.Conclusion: Diffuser mask (DMG) appears to be better than simple face mask (SMG) in the first hour of treatment of CO intoxication.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Aim: In patients who do not have any indication for hyperbaric oxygen (O2) treatment, the main treatment to eliminate carbon monoxide (CO) is by giving O2 using a face mask. In the absence of a non-rebreathing face mask, a diffuser mask (DMG) or simple face mask (SMG) is an option that can be used for treatment. There are insufficient data about the acute efficacy of these masks. To study the ability of DMG and SMG in lowering carboxyhemoglobin (COHb) levels after the first hour of O2 treatment in patients with CO intoxication.Materials and Methods: This was a prospective randomized clinical study conducted in patients aged ≥16 years old who were diagnosed with CO intoxi-cation. They were randomly given 15 L/min O2 (from hospital central O2 supplies) treatment with DMG (n=29) or SMG (n=52). Partial pressure of O2 (PaO2), carbon dioxide, and COHb levels and saturation of O2 were measured before and after 1 h of treatment.Results: A total of 81 (42 female and 39 male) patients with a mean age of 39.1±14.7 years were included in the study. There were no differences with regard to age, gender, body mass index, comorbidity, source of CO, initial symptoms, and initial COHb levels before treatment. After the first hour of treatment, DMG had lower mean COHb (mg/dL) levels (9.6±5.0 vs. 12.8±6.2, p=0.0203) and higher mean PaO2 levels (224.4±56.5 vs. 183.4±63.7, p=0.0046) than SMG.Conclusion: Diffuser mask (DMG) appears to be better than simple face mask (SMG) in the first hour of treatment of CO intoxication.

🔖

Bu Makaleye Atıf Yap

HOCAGİL, H., HOCAGİL, A. C., TATLİ, M. (2022). Does Simple Face Mask or Diffuser Mask Matter in the First Hour Treatment of Carbon Monoxide Intoxication? A Prospective Randomized Clinical Study. Eurasian Journal of Emergency Medicine, Cilt: 17 - Sayı: 4, 165–170. https://ajindex.com/articles/508053

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (2)

  1. Lippi G, Rastelli G, Meschi T, Borghi L, Cervellin G. Pathophysiology, clinics, diagnosis and treatment of heart involvement in carbon monoxide poisoning. Clin Biochem. 2012; 45: 1278-85. [CrossRef] Shen CH, Peng CK, Chou YC, Pan KT, Chang SC, Chang SY, et al. Predicting duration of mechanical ventilation in patients with carbon monoxide poisoning. J Crit Care. 2015; 30: 19-24. [CrossRef] Teerapuncharoen K, Sharma NS, Barker AB, Wille KM, Diaz-Guzman Successful treatment of severe carbon monoxide poisoning and refractory shock using extracorporeal membrane oxygenation. Respir Care. 2015; 60: 155-60. [CrossRef] Zahger D, Slutzky O, Almog Y. Severe reversible left ventricular dysfunction inducedvby carbon monoxide intoxication. Am J Emerg Med. 2002; 20: 572-3. [CrossRef] Park EJ, Min YG, Kim GW, Cho JP, Maeng WJ, Choi SC. Pathophysiology of brain injuries in acute carbon monoxide poisoning: A novel hypothesis. Med Hypotheses. 2014; 83: 186-9. [CrossRef] Hocagil H, Tanrıkulu CS, Ulker V, Kaya U, Koca L, Hocagil AC. Asymptomatic myocardial ınjury in a low level of carbon monoxide poisoning. Eurasian Emerg Med. 2015; 14: 91-3. [CrossRef] Gorman D, Drewry A, Huang-Yin L. The clinical toxicology of carbon monoxide. Toxicology. 2003; 187: 25-38. [CrossRef] Juric-Damijana M, Finderle Z, Suput D, et al. The effectiveness of oxygen therapy in carbon monoxide poisoning is pressure- and time-dependent: study on cultured astrocytesoriginal. Toxicology. 2015; 233: 16-23.
  2. Hampson-Neil B, Piantadosi-Claude A, Thom-Stephen R. Practice recommendations in the diagnosis, management, and prevention of carbon monoxide poisoning. Am J Respir Crit Care Med. 2012; 186: 1095-101. [CrossRef] Suena-Winnie W, Ridleya B, Blakneya G, Higgins TN. Comparison of lactate, bilirubin and hemoglobin F concentrations obtained by the ABL 700 series blood gas analyzers with laboratory methods. Clin Biochem. 2003; 36: 103-7. [CrossRef] Pyne-David B, Boston T, David-Martin T, Logan A. Evaluation of the Lactate Pro blood lactate analyser. Eur J Appl Physiol. 2000; 82: 112-6.[CrossRef] Beecroft JM, Hanly PJ. Hanly-Patrick J Comparison of the OxyMask and Venturi mask in the delivery of supplemental oxygen: Pilot study in oxygen-dependent patients. Can Respir J 2006; 13: 247-52. [CrossRef] Bateman-Nicholas D. Carbon monoxide. Medicine. 2012; 40: 115-6. [CrossRef] Prockop-Leon D, Chichkova-Rossitza I. Carbon monoxide intoxication: An updated review. J Neurol Sci. 2007; 262: 122-30. [CrossRef] Buckley NA1