Dergiler / Diagnostic and Interventional Radiology / 2022 / Cilt: 28 - Sayı: 1

CT dose management for neurologic events in patients with cardiac devices: Radiation exposure variation in patients with cardiac devices

Sayfa
98–102
Yayın Tarihi
2022-10-11
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

CONCLUSION Cranial CT acquisition parameters and radiation doses vary significantly between centers, which necessitates optimization of cranial CT protocols to overcome the cumulative radiation dose burden in patients with neurologic events.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:PURPOSE We aimed to compare the inter-center cranial computed tomography (CT) acquisition rates, CT findings, CT-related radiation dose, and variability of CT acquisition parameters for neurologic events among patients with implantable cardioverter-defibrillator (ICD) or left ventricular assist device (LVAD).
📊
Temel Bulgular & Veri:METHODS A total of 224 patients (ICD group, n=155; LVAD group, n=69) who had at least one cranial CT scan were enrolled from 3 medical centers (Centers A, B, and C).
💡
Sonuç & Katkı:CONCLUSION Cranial CT acquisition parameters and radiation doses vary significantly between centers, which necessitates optimization of cranial CT protocols to overcome the cumulative radiation dose burden in patients with neurologic events.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

PURPOSE We aimed to compare the inter-center cranial computed tomography (CT) acquisition rates, CT findings, CT-related radiation dose, and variability of CT acquisition parameters for neurologic events among patients with implantable cardioverter-defibrillator (ICD) or left ventricular assist device (LVAD). METHODS A total of 224 patients (ICD group, n=155; LVAD group, n=69) who had at least one cranial CT scan were enrolled from 3 medical centers (Centers A, B, and C). The variability and effect of the number, indication, and findings of cranial CT scans as well as CT acquisition parameters including tube potential (kV), tube current (mAs), tube rotation time, slice collimation, and spiral or sequential scanning techniques on CT dose index volume (CTDIvol), and total dose length product (DLP) were analyzed. RESULTS The mean DLP value of Center A and the mean CTDIvol values of Centers A and C were significantly lower than those of Center B (P < .001). The mean CTDIvol and DLP values in the ICD group were substantially lower than in the LVAD group (P < .001). The most potent parameters causing the changes in CTDIvol and DLP were kV, mAs values, and the CT scanning technique (sequential or spiral), according to multivariate linear regression analysis. CONCLUSION Cranial CT acquisition parameters and radiation doses vary significantly between centers, which necessitates optimization of cranial CT protocols to overcome the cumulative radiation dose burden in patients with neurologic events.

🔖

Bu Makaleye Atıf Yap

ONUR, M. R., ÇİFTÇİ, E., PARLAK, Ş., AYTEMİR, K., CANPOLAT, U., KAYA, E. B., OĞUZ, K. K., ÇOBAN, G., ERARSLAN, C. (2022). CT dose management for neurologic events in patients with cardiac devices: Radiation exposure variation in patients with cardiac devices. Diagnostic and Interventional Radiology, Cilt: 28 - Sayı: 1, 98–102. https://ajindex.com/articles/487247

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Broder J, Warshauer DM. Increasing utilization of computed tomography in the adult emergency department, 2000-2005. Emerg Radiol. 2006
  2. 13(1):25-30. [CrossRef] 2. Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005
  3. 352(3):225-237. [CrossRef] 3. Dew MA, Kormos RL, Winowich S, et al. Quality of life outcomes in left ventricular assist system inpatients and outpatients. ASAIO J. 1999
  4. 45(3):218-225. [CrossRef] 4. Toda K, Sawa Y. Clinical management for complications related to implantable LVAD use. Gen Thorac Cardiovasc Surg. 2015
  5. 63(1):1-7. [CrossRef] 5. Deng MC, Edwards LB, Hertz MI, et al. Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: third annual report--2005. J Heart Lung Transplant. 2005
  6. 24(9):1182-1187. [CrossRef] 6. Schmid C, Weyand M, Nabavi DG, et al. Cerebral and systemic embolization during left ventricular support with the Novacor N100 device. Ann Thorac Surg. 1998
  7. 65(6):1703-1710. [CrossRef] 7. Brenner DJ, Hall EJ. Computed tomography— an increasing source of radiation exposure. N Engl J Med. 2007
  8. 357(22):2277-2284. [CrossRef] 8. Sodickson A, Baeyens PF, Andriole KP, et al. Recurrent CT, cumulative radiation exposure, and associated radiation-induced cancer risks from CT of adults. Radiology. 2009
  9. 251(1):175- 184. [CrossRef] 9. Mayo-Smith WW, Hara AK, Mahesh M, Sahani DV, Pavlicek W. How I Do it: managing radiation dose in CT. Radiology. 2014
  10. 273(3):657- 672. [CrossRef] 10. Raman SP, Mahesh M, Blasko RV, Fishman EK. CT Scan parameters and radiation dose: practical advice for radiologists. J Am Coll Radiol. 2013
  11. 10(11):840-846. [CrossRef] 11. Verdun FR, Gutierrez D, Schnyder P, et al. CT dose optimization when changing to CT multidetector row technology. Curr Probl Diagn Radiol. 2007
  12. 36(4):176-184. [CrossRef] 12. Long B, Robertson J, Koyfman A, Brady W. Left ventricular assist devices and their complications: a review for emergency clinicians. Am J Emerg Med. 2019
  13. 37(8):1562-1570. [CrossRef] 13. Uriel N, Pak SW, Jorde UP, et al. Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation. J Am Coll Cardiol. 2010
  14. 56(15):1207-1213. [CrossRef] 14. Suarez J, Patel CB, Felker GM, et al. Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist dev