Dergiler / Diagnostic and Interventional Radiology / 2022 / Cilt: 28 - Sayı: 3

Percutaneous nephrostomy for nondilated renal collecting system with ultrasound and fluoroscopic guidance: The results of a 10-year experience

Sayfa
244–248
Yayın Tarihi
2022-10-11
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

CONCLUSION Ultrasound- and fluoroscopy-guided PCN for nondilated renal collecting system was feasible with acceptable technical success rate, complication rate, procedure time, and radiation exposure.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:PURPOSE This study aimed to evaluate the technical success rate, complications, and radiation doses of ultrasound- and fluoroscopy-guided percutaneous nephrostomy (PCN) in patients with a nondilated renal collecting system.
📊
Temel Bulgular & Veri:METHODS Over a 10-year period, 50 patients were referred for PCN of 60 kidneys with a nondilated renal collecting system.
💡
Sonuç & Katkı:CONCLUSION Ultrasound- and fluoroscopy-guided PCN for nondilated renal collecting system was feasible with acceptable technical success rate, complication rate, procedure time, and radiation exposure.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

PURPOSE This study aimed to evaluate the technical success rate, complications, and radiation doses of ultrasound- and fluoroscopy-guided percutaneous nephrostomy (PCN) in patients with a nondilated renal collecting system. METHODS Over a 10-year period, 50 patients were referred for PCN of 60 kidneys with a nondilated renal collecting system. The patients included 22 males and 28 females with a mean age of 63.2 years (range: 35-87 years). The most common reason for PCN in these patients was postoperative ureteral leaks and/or fistula (21/50 patients). PCN was performed under ultrasound and fluoroscopic guidance. During PCN, intravenous contrast media or diuretics were not used. Technical success rate, complications, procedure time, and radiation exposure of the procedure were retrospectively evaluated. RESULTS Ultrasound- and fluoroscopy-guided PCN for nondilated renal collecting system showed a success rate of 83.3% (50/60 kidneys) in the initial attempt. Four PCNs were repeated and were successful after the initial PCN failure. There was 1 major complication of bleeding that required transfusion in 1.9% (1/54) PCNs and there were minor complications of transient gross hematuria through the PCN catheter in 31.5% (17/54) PCNs. Mean duration of the procedure was 15.97 ± 7.81 min and median fluoroscopy time was 4.2 min (range: 1.2-15.3 min). Median dose area product and cumulative dose were 345.37 μGy·m2 (range: 42.57-1659.76 μGy·m2) and 46.9 mGy (range: 7.7-267.8 mGy), respectively. CONCLUSION Ultrasound- and fluoroscopy-guided PCN for nondilated renal collecting system was feasible with acceptable technical success rate, complication rate, procedure time, and radiation exposure.

🔖

Bu Makaleye Atıf Yap

LEE, S. M., CHU, H. H., PARK, S. E., WON, J. H., KIM, J. W., CHOI, H. C., SHIN, J. H., YANG, W. J. (2022). Percutaneous nephrostomy for nondilated renal collecting system with ultrasound and fluoroscopic guidance: The results of a 10-year experience. Diagnostic and Interventional Radiology, Cilt: 28 - Sayı: 3, 244–248. https://ajindex.com/articles/487226

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Pabon-Ramos WM, Dariushnia SR, Walker TG, et al. Quality improvement guidelines for percutaneous nephrostomy. J Vasc Interv Radiol. 2016
  2. 27(3):410-414. [CrossRef] 2. Patel U, Hussain FF. Percutaneous nephrostomy of nondilated renal collecting systems with fluoroscopic guidance: technique and results. Radiology. 2004
  3. 233(1):226-233. [CrossRef] 3. Degirmenci T, Gunlusoy B, Kozacioglu Z, et al. Utilization of a modified Clavien Classification System in reporting complications after ultrasound- guided percutaneous nephrostomy tube placement: comparison to standard Society of Interventional Radiology practice guidelines. Urology. 2013
  4. 81(6):1161-1167. [CrossRef] 4. Yagci C, Ustuner E, Atman ED, Baltaci S, Uzun C, Akyar S. Diuretic agent and normal saline infusion technique for ultrasound-guided percutaneous nephrostomies in nondilated pelvicaliceal systems. Cardiovasc Intervent Radiol. 2013
  5. 36(2):492-497. [CrossRef] 5. Gupta S, Gulati M, Suri S. Ultrasound-guided percutaneous nephrostomy in non-dilated pelvicaliceal system. J Clin Ultrasound. 1998
  6. 26(3):177-179. [CrossRef] 6. Sommer CM, Huber J, Radeleff BA, et al. Combined CT- and fluoroscopy-guided nephrostomy in patients with non-obstructive uropathy due to urine leaks in cases of failed ultrasound- guided procedures. Eur J Radiol. 2011
  7. 80(3):686-691. [CrossRef] 7. Merkle EM, Hashim M, Wendt M, Lewin JS. MRguided percutaneous nephrostomy of the nondilated upper urinary tract in a porcine model. AJR Am J Roentgenol. 1999
  8. 172(5):1221- 1225. [CrossRef] 8. Ray CE, Jr, Brown AC, Smith MT, Rochon PJ. Percutaneous access of nondilated renal collecting systems. Semin Intervent Radiol. 2014
  9. 31(1):98-100. [CrossRef] 9. Hausegger KA, Portugaller HR. Percutaneous nephrostomy and antegrade ureteral stenting: techn ique- indic ation s-com plica tions. Eur Radiol. 2006
  10. 16(9):2016-2030. [CrossRef] 10. Gupta S, Gulati M, Uday Shankar K, Rungta U, Suri S. Percutaneous nephrostomy with realtime sonographic guidance. Acta Radiol. 1997
  11. 38(3):454-457. [CrossRef] 11. Chalmers N, Jones K, Drinkwater K, Uberoi R, Tawn J. The UK nephrostomy audit. Can a voluntary registry produce robust performance data? Clin Radiol. 2008
  12. 63(8):888-894. [CrossRef] 12. Lin F, Yu W, Rao T, et al. The anatomic structure of a fused renal pyramid and its clinical significance in the establishment of percutaneous renal access. Urology. 2019
  13. [CrossRef] 13. Egilmez H, Oztoprak I, Atalar M, et al. The place of computed tomography as a guidance