Dergiler / Cumhuriyet Üniv. Tıp Fak. Derg. / 2003 / Cilt: 25 - Sayı: 1

Koroner arter hastalığı tanısında dobutamin stres Tc-99m sestamibi miyokard perfüzyon SPECT: Koroner anjiyografi sonuçlarıyla karşılaştırma

Dobutamine stress Tc-99m sestamibi myocardial perfusion SPECT in diagnosis of coronary artery disease: Comparison with coronary angiography results

Sayfa
22–30
Yayın Tarihi
2022-10-10
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

SPECT bulguları, kısa eksen ve vertikal uzun eksen kesitleri üzerinde 20 segmentten 5 dereceli skorlama yöntemi kullanılarak değerlendirildi.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Bu çalışmanın amacı, Gazi Ü.
📊
Temel Bulgular & Veri:Nükleer Tıp Anabilim Dalı'na miyokard perfüzyon SPECT (MP SPECT) görüntülemesi yapılması için başvuran ancak fizik egzersiz yapamayan koroner arter hastalığı (KAH) olgularında, dobutamin stres test ve Tc-99m sestamibi kullanılarak uygulanan aynı gün istirahat-stres SPECT görüntüleme protokolünün koroner anjiyografi (KA) sonuçlarıyla karşılaştırılarak tanısal etkinliğinin araştırılmasıydı.
💡
Sonuç & Katkı:SPECT bulguları, kısa eksen ve vertikal uzun eksen kesitleri üzerinde 20 segmentten 5 dereceli skorlama yöntemi kullanılarak değerlendirildi.
🔬Tür:Deneysel Tarla Denemesi
📍Kapsam:24 hasta
⚙️Değişkenler:Alan Parametreleri

Özet

Bu çalışmanın amacı, Gazi Ü. Tıp F. Nükleer Tıp Anabilim Dalı'na miyokard perfüzyon SPECT (MP SPECT) görüntülemesi yapılması için başvuran ancak fizik egzersiz yapamayan koroner arter hastalığı (KAH) olgularında, dobutamin stres test ve Tc-99m sestamibi kullanılarak uygulanan aynı gün istirahat-stres SPECT görüntüleme protokolünün koroner anjiyografi (KA) sonuçlarıyla karşılaştırılarak tanısal etkinliğinin araştırılmasıydı. Çalışma grubu, KAH olduğu bilinen ya da şüphelenilen 24 hastadan (3 kadın, 21 erkek) oluşmakta olup, yaş ortalaması 54.92$pm$7.91 idi (yaş aralığı:41-69). Tüm hastaların son 6 ay içerisinde yapılmış KA'leri vardı. Çalışma aynı gün, önce istirahat, ardından dobutamin stres düzeniyle yapıldı. 24 hastaya 10 mCi (370 MBq) Tc-99m sestamibi, istirahat dönemde, i.v. yolla enjekte edildi ve 60 dakika (dk) sonra, istirahat miyokard planar ve SPECT görüntülemeleri yapıldı. SPECT görüntüleme-sinden hemen sonra dobutamin infüzyonuna başlandı. 24 mCİ (888 MBq) Tc-99m sestamibi stres dozları, dobutamin infüzyonunu takiben i.v. yolla enjekte edildi. 60 dk sonra stres miyokard planar ve SPECT görüntülemeleri yapıldı. Elde edilen istirahat-stres planar ve SPECT görüntüleri görsel ve sayısal analizle değerlendirildi. Kalp-komşu organ (Kalp/Akciğer; K/AC ve Kalp/Karaciğer; K/KC) aktivite oranlan planar görüntülerden ilgi alanları çizilerek (ROI) hesaplandı. SPECT bulguları, kısa eksen ve vertikal uzun eksen kesitleri üzerinde 20 segmentten 5 dereceli skorlama yöntemi kullanılarak değerlendirildi. Stres ve istirahat dönemler için planar görüntülerden hesaplanan K/AC oranları arasında anlamlı farklılık bulunmazken (p>0.05), K/KC oranları arasında istatistiksel olarak anlamlı farklılık bulundu (p0.05). Sonuçlar damar lezyonlarına göre incelendiğinde; LAD bölgesi için duyarlılık %84, özgüllük %100, doğruluk %88, LCx bölgesi için duyarlılık %82, özgüllük %85, doğruluk %83, RCA bölgesi için duyarlılık %85, özgüllük %82, doğruluk %83 olarak hesaplandı. Genel duyarlılık %84, özgüllük %86, doğruluk ise %85 olarak hesaplandı.

Abstract

This study was performed in treadmill exercise unapplicable patients with known or suspected coronary artery disease at Gazi Univ. School of Medicine, Dept. of Nuclear Medicine. The purpose of this study was to evaluate the applicability of same day rest-stress myocardial perfusion SPECT protocol by using Tc-99m sestamibi and dobutamine pharmacological stress test. The results of Tc-99m sestamibi same day rest-dobutamine stress myocardial perfusion SPECT were compared with the coronary angiography results. Tc-99m sestamibi study group was consisted of 24 patients (3 female, 21 male) and the mean age was 54.92±7.91 (range:41-69 yrs). At rest, 10 mCi of Tc-99m sestamibi was injected intravenously. Sixty min after sestamibi injection, planar and SPECT acquisitions were performed. Dobutamine infusion was started just after the SPECT imaging. After dobutamine infusion, 24 mCi of Tc-99m sestamibi stress doses were injected intravenously. Sixty min after injection, stress planar and SPECT acquisitions were performed. Rest-stress planar and SPECT data were evaluated by using visual and semiquantitative analysis. Heart/organ activity ratios were calculated from the anterior planar images by using regions of interest (ROI). Myocardial perfusion SPECT data were interpreted by using 20 segment-5 point scoring system from short axis and vertical long axis slices. Statistically significant difference could not be found in H/Lu ratios between rest and stress conditions (p>0.05), vvhile there was Statistically significant difference in H/Li ratios (p0.05). For Tc-99m sestamibi SPECT study, sensitivity, specificity and accuracy were calculated as 84%, 100%, 88% for LAD, 82%, 85%, 83% for LCx and 85%, 82%, 83% for RCA, respectively. Overall sensitivity, specificity and accuracy were calculated as 84%, 86% and 85%, respectively.

🔖

Bu Makaleye Atıf Yap

TURGUT, B., ÜNLÜ, M., KİTAPÇI, M. T., TEMİZ, N. H. (2022). Koroner arter hastalığı tanısında dobutamin stres Tc-99m sestamibi miyokard perfüzyon SPECT: Koroner anjiyografi sonuçlarıyla karşılaştırma. Cumhuriyet Üniv. Tıp Fak. Derg., Cilt: 25 - Sayı: 1, 22–30. https://ajindex.com/articles/480172

Kaynakça (11)

  1. Zaret BL, Wackers FJ. Nuclear Cardiology. Review Article. N Eng J Med 1993; 329: 775-83
  2. Berman DS, Kiat H, Van Train KF, Friedman J, Garcia EV, Maddahi J. Comparison of SPECT using Technetium-99m agents and Thallium-201 and PET for the assessment of myocardial perfusion and viability. Am J Cardiol 1990; 66: 72E-79E
  3. Taillefer R. Overview of Tc99m labelled myocardial perfusion imaging agents: Advances in radiotracers and imaging of the heart. Congress Symposium, part-I, American Society Of Nuclear Cardiology, Minneapolis, Minnesota, Wednesday, June 14, 1995
  4. Wackers FJ, Berman DS, Maddahi J, Watson DD, Beller GA, Strauss HW, Boucher CA, Picard M, Holman BL, Fridrich R et al. Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 myocardial perfusion imaging. J Nucl Med 1989; 30: 301-11
  5. Kelly JD, Forster AM, Higley B, Archer CM, Booker FS, Canning LR, Wai Chiu K, Edwards B, Gill HK, McPartlin M, Nagle KR, Latham IA, Picket RD, Storey AE, Webbon PM. Technetium-99m Tetrofosmin as a new radiopharmaceutical for myocardial perfusion imaging. J Nucl Med 1993; 34: 222-7
  6. Jain D, Wackers FJ, Mattera J, McMahon M, Sinusas AJ, Zaret BL. Biokinetics of Technetium-99m tetrofosmin: Myocardial imaging agent: Implications for a one-day imaging protocol. J Nucl Med 1993; 34: 1254-9
  7. Higley B, Smith FW, Smith T, Gemmel HG, Gupta PD, Gvozdanovic DV, Graham D, Hinge D, Davidson J, Lahiri A. Technetium-99m 1,2-bis[bis(2-ethoxyethyl) phosphino] ethane: Human biodistribution, dosimetry and safety of a new myocardial perfusion imaging agent. J Nucl Med 1993; 34: 30-8
  8. Gerson MC, Lukes J, Deutsch E, Biniakiewicz D, Rohe RC, Washburn LC, Fortman C, Walsh RA. Comparison of Technetium-99m-Q12 and Tl-201 for detection of angiographically documented coronary artery disease in humans. J Nucl Cardiol 1994;1:1499-508
  9. Gerson MC, Millard RW, Roszell NJ, McGoron AJ, Gabel M, Wasburn LC, Biniakiewicz D, Blankenship D, Mallin WH, Elder RC, et al. Kinetic properties of Tc-99m Q12 in canine myocardium. Circulation 1994; 89: 1291-1300
  10. Schaefer WM, Moka D, Brockmann HA, Schomaecker K, Schicha H. Tl-201, Tc-99m MIBI, Tc-99m tetrofosmin and Tc-99m furifosmin: relative retention and clearance kinetics in retrogradely perfused guinea pig hearts. Nucl Med Biol 2002; 29: 243-54
  11. Rosenbaum AF, McGoron AJ, Millard RW, Gabel M, Biniakiewicz D, Walsh RA, Gerson MC. Uptake of seven myocard