Dergiler / Cumhuriyet Dental Journal / 2014 / Cilt: 17 - Sayı: 3

Mandibular 2 implant destekli overdenture protezlerde ataşmanlar üzerine gelen streslerin değerlendirilmesi

Evaluation of the stress on attachments of mandibular two-implant overdenture

Sayfa
279–290
Yayın Tarihi
2022-10-11
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Simetrik lokalizasyonlarda (LL), posterior bölgeden yapılan yüklemeler sonucundaBAya gelen stresler LAya gelen streslerden daha fazladır.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Bu çalışmanın amacı, mandibular 2 implant destekli overdenture protezlerde farklılokalizasyonlarda yerleştirilmiş implant üzerindeki 2 farklı tip ataşmana gelen streslerindeğerlendirilmesi.
📊
Temel Bulgular & Veri:Gereç ve Yöntem: Visible Human Project dataları VRMESH ve Rhinoceros 4.0 yazılımlarıyla,2 mm mukoza ve 2 mm kortikal tarafından çevrelenmiş trabeküler kemik özelliklerine sahip3 boyutlu (3B) mandibular modeli oluşturuldu.
💡
Sonuç & Katkı:Bulgular: Simetrik lokalizasyonlarda (LL), posterior bölgeden yapılan yüklemeler sonucundaBAya gelen stresler LAya gelen streslerden daha fazladır.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:6 adet
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Bu çalışmanın amacı, mandibular 2 implant destekli overdenture protezlerde farklılokalizasyonlarda yerleştirilmiş implant üzerindeki 2 farklı tip ataşmana gelen streslerindeğerlendirilmesi. Gereç ve Yöntem: Visible Human Project dataları VRMESH ve Rhinoceros 4.0 yazılımlarıyla,2 mm mukoza ve 2 mm kortikal tarafından çevrelenmiş trabeküler kemik özelliklerine sahip3 boyutlu (3B) mandibular modeli oluşturuldu. Mandibular 2 implant destekli overdentureprotezi simüle eden 3B modeller (toplam 6 adet) farklı implant lokalizasyonları ve farklı ataşmansistemleri kullanılarak tasarlandı. Modeller üzerine oklüzal yüklemeler (100N), yarım yuvarlaksert materyal (YYSM) ile farklı fonksiyonel hareketleri (çiğneme, ısırma) simüle edebilmek içinfarklı konumlardan yapılmıştır. Sonlu elemanlar analizi ALGOR FEMPRO yazılımı ile yapılıp,ataşmanlara gelen stresler Von Mises değerleri ile değerlendirilmiştir. Bulgular: Simetrik lokalizasyonlarda (LL), posterior bölgeden yapılan yüklemeler sonucundaBAya gelen stresler LAya gelen streslerden daha fazladır. Asimetrik konfigürasyonlarda (LCve LP), sol taraftaki implant posteriora doğru konumlandıkça, diğer tarafta bulunan implantüzerindeki hem BA hem de LAda Von Mises stresleri artmıştır. YYSM posterior yerleştirildiğinde,LC konfigürasyonunda BAda, LAya göre daha yüksek Von Mises stresleri gözlenirken, LPkonfigürasyonlarda LAda daha yüksek stresler tespit edilmiştir Sonuçlar: LL ve LP konfigürasyonlarında, LA daha düşük stres değerleri göstermiştir. Bu sonuç,klinisyenlere implant destekli overdenture protez yaparken seçecekleri ataşman türü hakkındaöncülük edecektir.

Abstract

Objectives: The aim of this study was to evaluate the effect of implant locations on the stressaround the two different attachment systems in mandibular two-implant overdentures. Materials and Methods: The data obtained from Visible Human Project were modified withthe use of VRMESH and Rhinoceros 4.0 software to establish a 3D mandible model with 2 mmcortical bone covering the trabecular bone and 2 mm mucosae. 3D models (totally 6 models)of mandibular two-implant overdenture were designed according to different implant locations[lateral-lateral (LL), lateral-canine (LC), lateral-first premolar (LP)] and attachment systems [ball(BA), locator (LA)]. Foodstuff was used for occlusal loading (100N) and to simulate differentbiting configurations, foodstuff was positioned on incisors (anterior) and between the secondpremolar and first molar (posterior) bilaterally. The finite element analysis was performed byALGOR FEMPRO software and von Mises stresses on attachments were evaluated. Results: For symmetric configuration (LL), there was more von Mises stress on BA comparedto LA when foodstuff was positioned posteriorly. For asymmetric configurations (LC and LP),when the implant in the asymmetric side was positioned more posteriorly, von Mises stressesincreased on both BA and LA of the implant positioned in the opposite side. In LC configuration,on BA higher von Mises stresses detected when compared to LA, whereas in LP configurationthe higher stresses determined on LA when foodstuff was positioned posteriorly. Conclusions: In LL and LP configurations, LA showed lower stresses, which should lead theclinician to choose the appropriate attachment system according to the individual clinicalsituation.

🔖

Bu Makaleye Atıf Yap

KURTULMUŞ, S. Y., RAMOĞLU, S., OZAN, O. (2022). Mandibular 2 implant destekli overdenture protezlerde ataşmanlar üzerine gelen streslerin değerlendirilmesi. Cumhuriyet Dental Journal, Cilt: 17 - Sayı: 3, 279–290. https://ajindex.com/articles/477138

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Mericske-Stern RD, Taylor TD, Belser U. Management of the edentulous patient. Clin Oral Implants Res 2000
  2. 11 Suppl 1:108-125 2. Allen PF, McMillan AS. A review of the functional and psychosocial outcomes of edentulousness treated with complete replacement dentures. J Can Dent Assoc 2003
  3. Tomruk CÖ, Özkurt Z, Şençift K, Kazazoğlu E. İmplant destekli overdenture ve klasik tam protezlerin hasta memnuniyeti açısından karşılaştırılması. Cumhuriyet Dent J 2013
  4. Feine JS, Carlsson GE, Awad MA, Chehade A, Duncan WJ, Gizani S, et al. The McGill consensus statement on overdentures. Mandibular two- implant overdentures as first choice standard of care for edentulous patients. Montreal, Quebec, May 24-25, 2002. Int J Oral Maxillofac Implants 2002
  5. British Society for the Study of Prosthetic Dentistry. The York consensus statement on implant- supported overdentures. Eur J Prosthodont Restor Dent 2009
  6. Bilhan H, Geckili O, Mumcu E, Bilmenoglu C. Maintenance requirements associated with mandibular implant overdentures: clinical results after first year of service. J Oral Implantol 2011
  7. Botega DM, Mesquita MF, Henriques GE, Vaz LG. Retention force and fatigue strength of overdenture attachment systems. J Oral Rehabil 2004
  8. Cekiç C, Akça K, Cehreli MC. Effects of attachment design on strains around implants supporting overdentures. Quintessence Int 2007
  9. Heckmann SM, Schrott A, Graef F, Wichmann MG, Weber HP. Mandibular two-implant telescopic overdentures. Clin Oral Implants Res 2004
  10. Kulak-Özkan Y. Tam protezler ve implant üstü hareketli protezlerde problemler ve çözüm yolları. İstanbul: Vestiyer Yayıncılık 2012:291-427. 11. Kleis WK, Kämmerer PW, Hartmann S, Al-Nawas B, Wagner W. A comparison of three different attachment systems for mandibular two-implant overdentures: one-year report. Clin Implant Dent Relat Res 2010
  11. Uludag B, Polat S. İmplant destekli overdenture uygulamalarında kullanılan tutucular. Türkiye Klinikleri J Dental Sci-Special Topics 2010
  12. Geçkili O, Bural C, Bilmenoğlu Ç. İmplant destekli tam protezlerde kullanılan tutucu sistemler. EÜ Dişhek Fak Derg 2010
  13. Petropoulos VC, Mante FK. Comparison of retention and strain energies of stud attachments for implant overdentures. J Prosthodont 2011
  14. Misch CE. Dental Implant Prosthetics. St. Louis: Elsevier Mosby, 2005:98-256. 16. Uludağ B. Hassas Tutu