Dergiler / Clinical and Experimental Health Sciences / 2019 / Cilt: 9 - Sayı: 3

In Vitro Gap Changes After Porcelain Firing Cycles of Three and Four Unit of CAD/CAM Milling, Laser Sintering and Cast Metal Ceramic Restorations

Sayfa
271–277
Yayın Tarihi
2022-10-11
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

However, all the marginal gap values obtained were in clinical acceptance level for three and four-units FPD’s for all tested specimens.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: Marginal adaptation changes during the veneering process is an important factor in the clinical success of metal framework techniques such as conventional cast metal cores (LW), CAD-CAM Metal Milling (MM) and Direct Metal Laser Sintering (DMLS).
📊
Temel Bulgular & Veri:The aim of this study is to evaluate the marginal fit changes between three- and four- unit’s metal ceramic fixed partial dentures (FPD’s) fabricated by Lost Wax (LW), CAM Metal Milling (MM) and (Direct Metal Laser Sintering) DMLS metal framework techniques after porcelain firing cycles (PFC).Methods: A total of 60 stainless steel three and four unit FPD’s models were fabricated.
💡
Sonuç & Katkı:However, all the marginal gap values obtained were in clinical acceptance level for three and four-units FPD’s for all tested specimens.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Marginal gap · lost wax · CAD/ CAM

Abstract

Objectives: Marginal adaptation changes during the veneering process is an important factor in the clinical success of metal framework techniques such as conventional cast metal cores (LW), CAD-CAM Metal Milling (MM) and Direct Metal Laser Sintering (DMLS). The aim of this study is to evaluate the marginal fit changes between three- and four- unit’s metal ceramic fixed partial dentures (FPD’s) fabricated by Lost Wax (LW), CAM Metal Milling (MM) and (Direct Metal Laser Sintering) DMLS metal framework techniques after porcelain firing cycles (PFC).Methods: A total of 60 stainless steel three and four unit FPD’s models were fabricated. Specimens were randomly divided into three groups to fabricate metal ceramic FPD’s frameworks with LW, MM and DMLS techniques. Before and after PFC, cross-sections from silicone replicas were obtained, sectioned, examined and measured with a light microscope. The statistical analysis was done with Mann-Whitney U and Kruskal Wallis and Wilcoxon Signed Ranks tests. Results were evaluated at 95 % of confidence interval and p<0.05 level.Results: There was a statistically significant difference between the three and four unit of FPD’s, before PFC for LW and MM (p:0.000) and DMLS (p:0.019)’s groups and only DMLS (p:0.006)’s group was statistically significant after PFC. The mean marginal gaps of LW technique was higher than the MM and DMLS’s techniques before PFC. After PFC, DMLS’s technique results were higher than LW and MM technique but, no statistically significant difference was found between the marginal gap values of the three and neither for four units of DMLS’s FPD’s.Conclusion: PFC decreases the mean marginal gap of the LW and MM group, but, there was a slight increase for DMLS group. However, all the marginal gap values obtained were in clinical acceptance level for three and four-units FPD’s for all tested specimens.

🔖

Bu Makaleye Atıf Yap

Keleş, M. A., Türker, Ş. B. (2022). In Vitro Gap Changes After Porcelain Firing Cycles of Three and Four Unit of CAD/CAM Milling, Laser Sintering and Cast Metal Ceramic Restorations. Clinical and Experimental Health Sciences, Cilt: 9 - Sayı: 3, 271–277. https://ajindex.com/articles/474359

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Nesse H, Ulstein DM, Vaage MM, Qilo M. Internal and marginal fit of cobalt chromium fixed dental prostheses fabricated with 3 different techniques. J Prosthet Dent. 2015;114(5): 686-692
  2. Ushiwata O, Moraes JV. Method for marginal measurements of restorations: Accessory device for toolmakers microscope. J Prosthet Dent. 2003;83: 362-366
  3. McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971;131(3): 107-111
  4. Goldin EB, Boyd NW, Goldstein GR, Hittelman EL, Thompson VP. Marginal fit of leucite-glass pressable ceramic restorations and ceramic pressed-to-metal restorations. J Prosthet Dent. 2005;93: 143-147
  5. Örtorp A, Jönsson D, Mouhsen A, von Steyern PV. The fit of cobalt- chromium three-unit fixed dental prostheses fabricated with four different techniques: A comparative in vitro study. Dent Mater. 2011;27: 356-363
  6. Ucar Y, Akova T, Akyil MS, Brantley WA. Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns. J Prosthet Dent. 2009;102(4): 253-259
  7. Kane LM, Chronaios D, Sierraalta M, George FM. Marginal and internal adaptation of milled cobalt-chromium copings. J Prosthet Dent. 2015;114(5):680-685
  8. Quante K, Quintas AF, Oliveira F, Bottino MA. Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents:an in vitro evaluation. J Prosthet Dent. 2004;92(3): 250-257
  9. Akova T, Ucar Y, Tukay A, Balkaya MC, Brantley WA. Comparison of the bond strength of laser-sintered and cast base metal dental alloys to porcelain. Dent Mater. 2008;24(10):1400-1404
  10. Sundar MJ, Chikmagalur SB, Pasha F. Marginal fit and microleakage of cast and metal laser sintered copings—An in vitro study. J Prosthodont Res. 2014;58: 252–258
  11. Persson A, Andersson M, Oden A, Sandborgh-Englund G. A three-dimensional evaluation of a laser scanner and a touch-probe scanner. J Prosthet Dent. 2006 Mar;95(3):194-200
  12. Gonzalo E, Suarez MJ, Serrano B, Lozano JF. A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation. J Prosthet Dent. 2009;102: 378-384
  13. Xu D, Xiang N, Wei B. The marginal fit of selective laser melting fabricated metal crowns: an in vitro study. J Prosthet Dent. 2014;112(6):1437-40
  14. Kim KB, Kim WC, Kim HY, Kim JH. An evaluation of marginal fit of three-unit fixed dental prostheses fab