Physical Leakage Analysis in Water Distribution Networks By Daily Consumption Curve

Sayfa
30–33
Yayın Tarihi
2017-12-31
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Operation and rehabilitation methods were suggested by determining the amount of physical leakage in the network.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:The curve of daily water consumption in drinking water networks provides a lot of information on the physical status of the network.
📊
Temel Bulgular & Veri:The existing physical leakage rate can be estimated by analyzing the network water consumption curve.
💡
Sonuç & Katkı:Operation and rehabilitation methods were suggested by determining the amount of physical leakage in the network.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Physical Leakage · Water Demand · Water Distribution Network

Özet

The curve of daily water consumption in drinking water networks provides a lot of information on the physical status of the network. The existing physical leakage rate can be estimated by analyzing the network water consumption curve. Hence, precautions can be taken in order to prevent the physical leakages and water losses. In this study, the minimum night flow (MNF) that occurs in the determined measurement areas (DMA) in the current drinking water network was examined, and it was attempted to determine the required amount of consumption and water loss by determining the amount of leakage. Pressure management was started to be used in the distribution system, and the effect of pressure management on the water consumption in DMAs was examined. Operation and rehabilitation methods were suggested by determining the amount of physical leakage in the network.

Abstract

The curve of daily water consumption in drinking water networks provides a lot of information on the physical status of the network. The existing physical leakage rate can be estimated by analyzing the network water consumption curve. Hence, precautions can be taken in order to prevent the physical leakages and water losses. In this study, the minimum night flow (MNF) that occurs in the determined measurement areas (DMA) in the current drinking water network was examined, and it was attempted to determine the required amount of consumption and water loss by determining the amount of leakage. Pressure management was started to be used in the distribution system, and the effect of pressure management on the water consumption in DMAs was examined. Operation and rehabilitation methods were suggested by determining the amount of physical leakage in the network.

🔖

Bu Makaleye Atıf Yap

KILIÇ, R., CİNAL, H. (2017). Physical Leakage Analysis in Water Distribution Networks By Daily Consumption Curve. Avrupa Bilim ve Teknoloji Dergisi, Sayı: Özel Sayı - Special Issue, 30–33. https://ajindex.com/articles/471903

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (1)

  1. Nicolini M., Giacomello C., Scarsini M., Mion M. 2014. Numerical modelling and leakage reduction in the water distribution system of, Procedia Engineering 70, 1241-1250. DOI: 10.1016/j.proeng.2014.02.137 Debiasi S., Giorgio Bort C.M., Bosoni A., Bertola P., Righetti M. 2014. Influence of hourly water consumption in model calibration for leakage detection in a WDS, Procedia Engineering 70, 467-476. DOI: 10.1016/j.proeng.2014.02.052 Wright R., Parpas P., Stoianov I. 2015. Experimental investigation of resilience and pressure management in water distribution networks, Procedia Engineering 119, 643-652. DOI: 10.1016/j.proeng.2015.08.917 Laucelli D., Meniconi S. 2015. Water distribution analysis accounting for different background leakage models, Procedia Engineering 119, 680-689. DOI: 10.1016/j.proeng.2015.08.921 Latchoomun L., Ah King R.T.F., Busawon K. 2015. A new approach to model development of Water distribution networks with high leakage and burst rates, Procedia Engineering 119, 690-699. DOI: 10.1016/j.proeng.2015.08.922