Dergiler / Balkan Medical Journal / 2016 / Cilt: 33 - Sayı: 3

Effectiveness of Using Dual-source CT and the Upshot it creates on Both Heart Rate and Image Quality

Sayfa
283–293
Yayın Tarihi
2022-10-11
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Two different groups categorizedby mean heart rate had almost similar results in terms ofthe diagnostic power of dual-source CTA.Conclusion: CTA with a high pitch value is a reliable,non-invasive diagnostic method that can CAD with lowradiation doses not only in patients with a heart rate below70 bpm, but also in patients with higher heart rates.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Background: Early detection of coronary artery disease(CAD) is important because of the high morbidity andmortality rates.
📊
Temel Bulgular & Veri:As invasive coronary angiography (ICA)is an invasive procedure, an alternative diagnostic method;coronary computed tomography angiography (CTA),has become more widely used by the improvements indetector technology.Aims: In this study, we aimed to examine the accuracyand image quality of high-pitch 128-slice dual-sourceCTA taking the ICA as reference technique.
💡
Sonuç & Katkı:Two different groups categorizedby mean heart rate had almost similar results in terms ofthe diagnostic power of dual-source CTA.Conclusion: CTA with a high pitch value is a reliable,non-invasive diagnostic method that can CAD with lowradiation doses not only in patients with a heart rate below70 bpm, but also in patients with higher heart rates.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Background: Early detection of coronary artery disease(CAD) is important because of the high morbidity andmortality rates. As invasive coronary angiography (ICA)is an invasive procedure, an alternative diagnostic method;coronary computed tomography angiography (CTA),has become more widely used by the improvements indetector technology.Aims: In this study, we aimed to examine the accuracyand image quality of high-pitch 128-slice dual-sourceCTA taking the ICA as reference technique. We alsoaimed to compare the accuracy and image quality betweendifferent heart rate groups of >70 beates per minute(bpm) and 50% was considered significant on a per-segment,per-vessel, and per-patient basis and ICA was consideredthe reference method. Radiation doses were determinedusing dose length product (DLP) values detected by thecomputed tomography (CT) device. In addition, patientswere classified into two groups according to their heartrates as 70 bpm (29 patients).The relation between the diagnostic accuracy andheart rate groups were evaluated.Results: Overall, 1495 (98%) coronary segments werediagnostic in 102 patients (32 male, 70 female, meanheart rate: 65 bpm). There was a significant correlationbetween image quality and mean heart rate in the rightcoronary artery (RCA) segments. The effective radiationdose was 0.98±0.09 mili Sievert (mSv). On a per-patientbasis, sensitivity, specificity, and positive and negativepredictive values were 93.8%, 88.8%, 93.8% and 88.8%,respectively. These values were also similar in per-vesseland per-segment basis. Two different groups categorizedby mean heart rate had almost similar results in terms ofthe diagnostic power of dual-source CTA.Conclusion: CTA with a high pitch value is a reliable,non-invasive diagnostic method that can CAD with lowradiation doses not only in patients with a heart rate below70 bpm, but also in patients with higher heart rates.

🔖

Bu Makaleye Atıf Yap

SELÇUK, T., SAVAŞ, Y., BULAKÇI, M., OTÇU, H., YÜCELER, Z., BİLGİLİ, Ç., ÇELİK, Ö. (2022). Effectiveness of Using Dual-source CT and the Upshot it creates on Both Heart Rate and Image Quality. Balkan Medical Journal, Cilt: 33 - Sayı: 3, 283–293. https://ajindex.com/articles/461260

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. de Azevedo CF, Hadlich MS, Bezerra SG, Petriz JL, Alves RR, de Souza O, et al. Prognostic value of CT angiographyin patients with inconclusive functional stres tests. JACC Cardiovasc Imaging 2011
  2. [CrossRef] 2. Hong YJ, Kim SJ, Lee SM, Min PK, Yoon YW, Lee BK, et al. Low-dose coronary computed tomography angiography using prospective ECG-triggering compared to invasive coronary angiography. Int J Cardiovasc Imaging 2011
  3. [CrossRef] 3. Hadamitzky M, Freissmuth B, Meyer T, Hein F, Kastrati A, Martinoff S, et al. Prognostic value of coronary computed tomographic angiography for prediction of cardiac events in patients with suspected coronary artery disease. JACC Cardiovasc Imaging 2009
  4. [CrossRef] 4. Achenbach S, Goroll T, Seltmann M, Pflederer T, Anders K, Ropers D, et al. Detection of coronary artery stenoses by low-dose, prospectively ECG-triggered, high-pitch spiral coronary CT angiography. JACC Cardiovasc Imaging 2011
  5. [CrossRef] 5. Ehara M, Surmely JF, Kawai M, Katoh O, Matsubara T, Terashima M, et al. Diagnostic accuracy of 64-slice computed tomography for detecting angiographically significant coronary artery stenoses in an unselected consequtive patient population: comparison with conventional invasive angiography. Circ J 2006
  6. [CrossRef] 6. Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 2005
  7. [CrossRef] 7. Leschka S, Alkadhi H, Plass A, Desbiolles L, Grünenfelder J, Marincek B, et al. Accuracy of MSCT coronary angiography with 64-slice technology: first experience. Eur Heart J 2005
  8. [CrossRef] 8. Bayraktutan U, Kantarcı M, Gundogdu F, Demirelli S, Yuce I, Oğul H, et al. Efficacy of ivabradin to reduce heart rate prior to coronary CT angiography: comparison with beta-blocker. Diagn Interv Radiol 2012
  9. Lell M, Marwan M, Schepis T, Pflederer T, Anders K, Flohr T, et al. Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience. Eur Radiol 2009
  10. [CrossRef] 10. Achenbach S, Marwan M, Ropers D, Schepis T, Pflederer T, Anders K, et al. Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition. Eur Heart J 2010
  11. [CrossRef] 11. Achenbach S, Anders K, Kalender WA. Du