Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The obtained results reveal that the reconstructed images are well-matched to the original images, which are desired to be displayed by the holography technique.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Optical imaging has attracted recent attention as a non-invasive medical imaging method in biomedical and clinical applications.
📊
Temel Bulgular & Veri:Based on the light intensity of these received beams on the sensor, sub-tissue maps are generated to scan large tissue areas so that any further biopsy is not required.
💡
Sonuç & Katkı:The obtained results reveal that the reconstructed images are well-matched to the original images, which are desired to be displayed by the holography technique.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Optical imaging has attracted recent attention as a non-invasive medical imaging method in biomedical and clinical applications. In optical imaging, a light beam is transmitted through an under-test tissue by using an optical source. The beams which are gone through the tissue and/or reflected from the tissue surfaces are received by an array sensor. Based on the light intensity of these received beams on the sensor, sub-tissue maps are generated to scan large tissue areas so that any further biopsy is not required. Although the large tissue areas in pathological images can be scanned by using various methods, nonlinear deformations occur. To overcome this problem, the reconstruction process is frequently used. In this study, we propose an application of biomedical imaging based on performing the reconstruction of a phantom image via an in-line digital holography technique. Hence, many different sub-tissues can be imaged at the same time without the storage problem of the reconstructed image. To neglect the biopsy process required in medical imaging, the phantom image is obtained by using a linear array transducer for this study. We present the performance evaluation of the simulation results for the proposed technique by calculating the error metrics such as mean squared error (MSE), mean absolute error (MAE) and peak signal-to-noise ratio (PSNR). The obtained results reveal that the reconstructed images are well-matched to the original images, which are desired to be displayed by the holography technique.

🔖

Bu Makaleye Atıf Yap

ONUR, T. Ö., KAYA, G. U. (2022). Reconstruction with In-Line Digital Holography Quantitative Phase Imaging for TissueMimicking Phantom Samples. Balkan Journal of Electrical and Computer Engineering, Cilt: 9 - Sayı: 2, 213–220. https://ajindex.com/articles/460422

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. D. Welch, A.D. Harken, G. Randers?Pehrson, D.J. Brenner. "Construction of mouse phantoms from segmented CT scan data for radiation dosimetry studies." Phys Med Biol. vol. 60, 1, 2015, pp 3589- 3598
  2. F. Zito, E. De Bernardi, C. Soffientini, C. Canzi, R. Casati, P. Gerundini, G. Baselli. "The use of zeolites to generate PET phantoms for the validation of quantification strategies in oncology." Med Phys. Vol. 39, 9, 2012, pp 5353-5361
  3. A. Hellerbach, V. Schuster, A. Jansen, J. Sommer. "MRI phantoms - are there alternatives to Agar?" PLoS ONE, vol. 8, 8, 2013, pp e70343
  4. A.P. Gibson, J.C. Hebden, S.R. Arridge. "Recent advances in diffuse optical imaging." Phys. Med. Biol. Vol 50, 4, 2005, pp R1-R43 [5] G.D. Lieo, R.M. Trimboli, T. Sella, F. Sardanelli. "Optical imaging of the breast: basic principles and clinical applications." American Journal of Roentgenology, vol. 290, 1, 2017, pp 230-238
  5. A. Anand, I. Moon, B. Javidi. "Automated disease identification with 3- D optical imaging: a medical diagnostic tool." Proc. IEEE, vol. 105, 5, 2017, pp 924-946
  6. F. Maes, D. Loeckx, D. Vandermeulen, P. Suetens, Image registration using mutual information. In: Handbook of biomedical imaging, Springer US, 2015, p. 295-308
  7. U. Schnars, W. Jueptner, Digital Holography: Digital Hologram Recording, Numerical Reconstruction, and Related Techniques, Springer-Verlag Berlin Heidelberg, 2005, p. 164
  8. A. Doblas, E. Roche, F. Ampudia-Blasco, M. Martinez-Corral, G. Saavedra, and J. Garcia-Sucerquia. "Diabetes screening by telecentric digital holographic microscopy." J. Microsc. Vol. 261, 3, 2016, pp 285- 290
  9. C. D. Depeursinge, E. Cuche, T. Colomb, P. Dahlgren, A. M. Marian, F. Monfort, P. Marquet, P. J. Magistretti, "Cells and tissue imaging with digital holographic microscopy." Novel Optical Instrumentation for Biomedical Applications, 14 October 2003, SPIE vol. 5143
  10. N.F. Boyd, H. Guo, L.J. Martin. "Mammographic density and the risk and detection of breast cancer." N. Engl. J. Med. vol. 356, 3, 2007 pp 227-236
  11. C.K. Kuhl. "Current status of breast MR imaging. Part 2: clinical applications."Radiology, vol. 244, 3, 2007, pp 672-691
  12. N.H. Peters, R. Borel, N.P. Zuithoff, W.P. Mali, K.G. Moons, P.H. Peeters. "Meta-analysis of MR imaging in the diagnosis of breast lesions." Radiology, vol. 246,1, 2008, pp 116-124
  13. C. C. Chen, Y.L. Wan, Y.Y., Wai, H.L. Liu. "Quality assurance of clinical MRI scanners using ACR MRI phantom: prelimina