Dergiler / Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi / 2019 / Cilt: 29 - Sayı: 1

DEZENFEKTAN KULLANIMININ ELASTOMERİK ÖLÇÜ MATERYALLERİNİN BOYUTSAL STABİLİTESİ ÜZERİNE ETKİSİNİN İN VİTRO OLARAK İNCELENMESİ

IN VITRO EVALUATION OF THE EFFECT OF DISINFECTION PROCEDURES ON DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS

Sayfa
12–19
Yayın Tarihi
2022-10-10
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Hazırlanan alçı modeller üç boyutlu bir dentaltarama cihazında taranarak dijital görüntüleri oluşturuldu.Elde edilen dijital model görüntüleri üzerinde cihazın kendiyazılımı kullanılarak referans noktaları arasında lineerölçümler yapıldı.Bulgular: Elde edilen verilerin istatistiksel analizi SPSS22.0 programı kullanılarak yapılmıştır.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Bu çalışmanın amacı iki farklı sprey dezenfektankullanımının elastomerik ölçü maddelerinin boyutsalstabilitesi üzerine etkisinin in vitro olarak incelenmesidir.Gereç ve Yöntem: Çalışmamızda 3 farklı ölçü mad- desi(polieter, kondensasyon tip silikon ve ilave tip silikon) veiki farklı sprey dezenfektan (Zeta 7: isop- ropanol esaslıve Descosept: kuarterner amonyum bileşikleri esaslı)kullanıldı.
📊
Temel Bulgular & Veri:Ölçülerin alınması için pas - lanmaz çelik modelkullanıldı ve her bir ölçü madde - sinden 30 adet olacakşekilde, toplam 90 adet ölçü elde edildi .
💡
Sonuç & Katkı:Hazırlanan alçı modeller üç boyutlu bir dentaltarama cihazında taranarak dijital görüntüleri oluşturuldu.Elde edilen dijital model görüntüleri üzerinde cihazın kendiyazılımı kullanılarak referans noktaları arasında lineerölçümler yapıldı.Bulgular: Elde edilen verilerin istatistiksel analizi SPSS22.0 programı kullanılarak yapılmıştır.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:30 adet
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Bu çalışmanın amacı iki farklı sprey dezenfektankullanımının elastomerik ölçü maddelerinin boyutsalstabilitesi üzerine etkisinin in vitro olarak incelenmesidir.Gereç ve Yöntem: Çalışmamızda 3 farklı ölçü mad- desi(polieter, kondensasyon tip silikon ve ilave tip silikon) veiki farklı sprey dezenfektan (Zeta 7: isop- ropanol esaslıve Descosept: kuarterner amonyum bileşikleri esaslı)kullanıldı. Ölçülerin alınması için pas - lanmaz çelik modelkullanıldı ve her bir ölçü madde - sinden 30 adet olacakşekilde, toplam 90 adet ölçü elde edildi . Her bir ölçümaddesi için 10’ar örnek içeren 3 grup oluşturuldu. Zeta 7ve Descosept sprey uygulanan gruplar 15 dakika bekletildive akan su altında yıkandı . Diğer grup ise kontrol grubuolarak kullanıldı. Ölçülere sert alçı dökülerek modeller eldeedildi. Hazırlanan alçı modeller üç boyutlu bir dentaltarama cihazında taranarak dijital görüntüleri oluşturuldu.Elde edilen dijital model görüntüleri üzerinde cihazın kendiyazılımı kullanılarak referans noktaları arasında lineerölçümler yapıldı.Bulgular: Elde edilen verilerin istatistiksel analizi SPSS22.0 programı kullanılarak yapılmıştır. Verilerin normaldağılıma uyup uymadığı Shapiro-Wilk testi ile kontrol edilmişve verilerin normal dağılıma uyması nedeniyle parametriktest kullanılmıştır. İki farklı dezenfektan materyalinin,farklı ölçü materyalleri üzerindeki boyutsal stabilitesineolan etkisinin değerlendirilmesi için independent ttesti kullanılmıştır. Sonuçlar %95’lik güven aralığındadeğerlendirilmiştir.Sonuç: Kondanse silikon grubunda her iki kimyasaldezenfektan ajanında boyutsal değişim açısından istatistikselolarak anlamlı fark gözlemlenmiştir (p

Abstract

Aim: The aim of this study was to determine the effect of spray disinfection procedures on the dimensional stability of elastomeric impression materials. Material and Methods: In our study, we used 3 different impression materials (polyether, condensation type silicone and additional type silicone) and two different spray disinfectants (Zeta 7: based on isopropanol and Descosept: based on quaternary ammonium compounds). A stainless steel model was used for taking measurements and at each to be 30, a total of 90 measurements was obtained. For each impression materials, 3 groups of 10 samples were formed. Zeta 7 and Descosept sprayed groups were left for 15 minutes and washed under running water. The other group was used as the control group. Molds were filled with hard gypsum plaster. Dimensional stability were evaluated using a three-dimensional dental scanning device. Linear measurements were made between the reference points on the digital model images using the device's own software. Results: Statistical analysis was performed using the SPSS 22.0 program. The data was controlled by the Shapiro-Wilk test and parametric test was used because of the normal distribution of the data. Independent t test was used to assess the effect of disinfection procedures on dimensional stability of elastomeric impression materials. The results were evaluated in 95% confidence interval. Conclusion: There was statistically significant difference in the mean values of dimensional stability in condensation type silicone (p

🔖

Bu Makaleye Atıf Yap

KARA, D., GÜNAL, B. (2022). DEZENFEKTAN KULLANIMININ ELASTOMERİK ÖLÇÜ MATERYALLERİNİN BOYUTSAL STABİLİTESİ ÜZERİNE ETKİSİNİN İN VİTRO OLARAK İNCELENMESİ. Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi, Cilt: 29 - Sayı: 1, 12–19. https://ajindex.com/articles/451792

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (11)

  1. Chau VB, Saunders TR, Pimsler M, Elfring DR. Indepth disinfection of acrylic resins. J Prosthet Dent 1995;74:309-13.
  2. Powell GL, Runnels RD, Saxon BA, Whisenant BK. The presence and identification of organisms transmitted to dental laboratories. J Prosthet Dent 1990;64: 235-7.
  3. Gerhardt DE, Sydiskis RJ Impression materials and virüs. J Am Dent Assoc 1991;122: 51-4.
  4. Rice CD, Dykstra MA, Gier RE, Cobb CM. Microbial contamination in four brands of irreversible hydrocolloid impression materials. J Prosthet Dent 1991;65:419-23.
  5. Samaranayake LP, Hunjan M, Jennings KJ. Carriage of oral flora on irreversible hydrocolloid and elastomeric impression materials. J Prosthet Dent 1991;65: 244-9.
  6. Mitchell DL, Hariri NM, Duncanson MG Jr, Jacobsen NL, McCallum RE. Quantitative study of bacterial colonization of dental casts. J Prosthet Dent 1997;78:518-21.
  7. McNeil MR, Coulter WA, Hussey DL. Disinfection of irreversible hydrocolloid impressions: a comprative study. Int J Prosthodont 1992;5:563-7.
  8. Beyerle MP, Hensley DM, Bradley DV Jr, Schwartz RS, Hilton TJ. Immersion disinfection of irreversible hydrocolloid impressions with sodium hypochlorite. Part 1: microbiology. Int J Prosthodont 1994; 7:234-8. Vayısoğlu Özcan A, Nalbant L, Nalbant D. Protetik diş tedavisinde dezenfeksiyon ve sterilizasyon. Atatürk Üniv Diş Hek Fak Derg 2016; 26: 169-79.
  9. Vandewalle KS, Charlton DG, Schwartz RS, Reagan SE, Koeppen RG. Immersion disinfection of irreversible hydrocolloid impressions with sodium hypochlorite. Part II: effect on gypsum. Int J Prosthodont 1994;7:315 - 22. Lepe X, Johnson GH, Berg JC. Surface characteristics of polyether and addition silicone impression materials after long term disinfection. J Prosth Dent 1995;74:181-6.
  10. Hilton TJ, Schwartz RS, Bradley DV. Immersion disinfection of irreversible hydrocolloid impressions. Part 2: effects on gypsum casts. Int J Prosthodont 1994;7:424-33.
  11. Matyas J, Dao N, Caputo AA, Lucatorto FM. Effects of disinfectants on dimensional accuracy of impression materials. J Prosth Dent 1990;64:25 - 31. Council on Dental Materials, Instruments and Equipment. Disinfection of impression. J Am Dent Assoc 1991;122: 110 Kohn WG, Harte JA, Malvitz DM, Collins AS, Cleveland JL, Eklund KJ Guidelines for infection control in dental health care settings. J Am Dent Assoc 2004;135: 33-47 ADA Council on Scientific Affairs and ADA Council on Dental Practice.Infection control recommendations for the dental office and the dental laboratory. J Am Dent Assoc 1996;127:6