Dergiler / Archives of epilepsy (Online) / 2022 / Cilt: 28 - Sayı: 2

A Comparision of Video EEG Monitoring and Routine EEG for Diagnosis of Epilepsy

Sayfa
85–88
Yayın Tarihi
2022-10-12
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: Compared to routiene electroencephalogram, video electroencephalogram monitoring is superior in detecting epileptiform discharges.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: The aim of this study was to investigate the diagnostic utility of routine electroencephalogram and video electroencephalogram monitoring.
📊
Temel Bulgular & Veri:The yield of routiene electroencephalogram and video electroencephalogram monitoring was compared and assessed with the detection of epileptiform discharges.
💡
Sonuç & Katkı:Conclusion: Compared to routiene electroencephalogram, video electroencephalogram monitoring is superior in detecting epileptiform discharges.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Objective: The aim of this study was to investigate the diagnostic utility of routine electroencephalogram and video electroencephalogram monitoring. Methods: We performed a retrospective analysis on patients admitted to our video electroencephalogram monitoring unit. The yield of routiene electroencephalogram and video electroencephalogram monitoring was compared and assessed with the detection of epileptiform discharges. Results: Out of 191 patients, the epileptiform discharges found in routiene electroencephalogram and video electroencephalogram monitoring were 39 (21%) and 99 (52%), respectively. The yield of epileptiform discharges differed significantly between video electroencephalogram monitoring and routiene electroencephalogram (P < .001). While the epileptiform discharges detection rate (95% CI) was 0.29 (0.25-0.46) for routiene electroencephalogram, it was 0.93 (0.86- 0.97) for video electroencephalogram monitoring. Conclusion: Compared to routiene electroencephalogram, video electroencephalogram monitoring is superior in detecting epileptiform discharges.

🔖

Bu Makaleye Atıf Yap

ZORGÖR, G., GÜL, G., EREN, F., GÜL, Z. B. (2022). A Comparision of Video EEG Monitoring and Routine EEG for Diagnosis of Epilepsy. Archives of epilepsy (Online), Cilt: 28 - Sayı: 2, 85–88. https://ajindex.com/articles/447846

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Whittaker RG. Video telemetry: current concepts and recent advances. Pract Neurol. 2015
  2. 15(6):445-450. [CrossRef] 2. Boon PA, Williamson PD. The diagnosis of pseudoseizures. Clin Neurol Neurosurg. 1993
  3. 95(1):1-8. [CrossRef] 3. Perry TR, Gumnit RJ, Gates JR, Leppik IE. Routine EEG vs. intensive monitoring in the evaluation of intractable epilepsy. Public Health Rep. 1983
  4. 98(4):384-389. 4. DoppelbauerA, Zeitlhofer J, Zifko U, Baumgartner C, Mayr N, Deecke L. Occurrence of epileptiform activity in the routine EEG of epileptic patients. Acta Neurol Scand. 1993
  5. 87(5):345-352. [CrossRef]. 5. Modur PN, Rigdon B. Diagnostic yield of sequential routine EEG and extended outpatient video-EEG monitoring. Clin Neurophysiol. 2008
  6. 119(1):190-196. [CrossRef] 6. Salinsky M, Kanter R, Dasheiff RM. Effectiveness of multiple EEGs in supporting the diagnosis of epilepsy: an operational curve. Epilepsia. 1987
  7. 28(4):331-334. [CrossRef] 7. Marsan CA, Zivin LS. Factors related to the occurrence of typical paroxysmal abnormalities in the EEG records of epileptic patients. Epilepsia. 1970
  8. 11(4):361-381. [CrossRef]. 8. Baldin E, Hauser WA, Buchhalter JR, Hesdorffer DC, Ottman R. Yield of epileptiform electroencephalogram abnormalities in incident unprovoked seizures: a population-based study. Epilepsia. 2014
  9. 55(9):1389- 1398. [CrossRef]. 9. McGonigal A, Russell AJC, Mallik AK, Oto M, Duncan R. Use of short term video EEG in the diagnosis of attack disorders. J Neurol Neurosurg Psychiatry. 2004
  10. 75(5):771-772. [CrossRef] 10. Chayasirisobhon S, Griggs L, Westmoreland S, Kim CS. The usefulness of one to two hour video EEG monitoring in patients with refractory seizures. Clin Electroencephalogr. 1993
  11. 24(2):78-84. [CrossRef] 11. Goldstein L, Margiotta M, Guina ML, Sperling MR, Nei M. Long-term video-EEG monitoring and interictal epileptiform abnormalities. Epilepsy Behav. 2020
  12. 107523. [CrossRef] 12. Badawy RA, Curatolo JM, Newton M, Berkovic SF, Macdonell RA. Sleep deprivation increases cortical excitability in epilepsy: syndromespecific effects. Neurology. 2006
  13. 67(6):1018-1022. [CrossRef] 13. Angus-Leppan H. Seizures and adverse events during routine scalp electroencephalography: a clinical and EEG analysis of 1000 records. Clin Neurophysiol. 2007
  14. 118(1):22-30. [CrossRef]. 14. Ellingson RJ, Wilken K, Bennett DR. Efficacy of sleep deprivation as an activation procedure in epilepsy patients. J Clin Neurophysiol. 1984
  15. 1(1):83-101. [CrossRef] 15. Ajmone-Marsan C. Electroencephalographi