⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Results: There was a statistically significant and moderately negative correlation (r = -0.428, p

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Aim: Our aim in this study is to understand whether there is a correlation between IVC-CI, IJV-CI, CVP, and Delta-CO2 values in critical patients in the ICU and whether these values can be used interchangeably in monitoring intravascular fluid status..
📊
Temel Bulgular & Veri:Materials and Methods: Patients included in this study were selected from critical ICU patients between 18-90 years old with an unknown hypovolemic status that had spontaneous breathing and underwent invasive mechanical ventilation in CPAP mode.
💡
Sonuç & Katkı:Results: There was a statistically significant and moderately negative correlation (r = -0.428, p
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Aim: Our aim in this study is to understand whether there is a correlation between IVC-CI, IJV-CI, CVP, and Delta-CO2 values in critical patients in the ICU and whether these values can be used interchangeably in monitoring intravascular fluid status.. Materials and Methods: Patients included in this study were selected from critical ICU patients between 18-90 years old with an unknown hypovolemic status that had spontaneous breathing and underwent invasive mechanical ventilation in CPAP mode. Patients’ parameters were consecutively measured by USG with the inferior vena cava collapsibility index (IVC-CI), internal jugular vein collapsibility index (IJV-CI), CVP, and Delta-CO2. The results were recorded, and any correlations were checked. Results: There was a statistically significant and moderately negative correlation (r = -0.428, p

🔖

Bu Makaleye Atıf Yap

YEKTAŞ, A., KAÇAR, C. K., BIÇAK, M., KAYA, S., KANDEMİR, D., UZUNDERE, O. (2022). Evaluation of the relationship of Delta-CO2 with IVC-CI, IJV-CI, and CVP values in intubated critically ill patients with spontaneous breathing, and who were applied invasive mechanical ventilation in CPAP mode. Annals of Medical Research, Cilt: 27 - Sayı: 12, 3222–3227. https://ajindex.com/articles/446478

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Jassim HM, Naushad VA, Khatib MY, et al. IJV collapsibility index vs IVC collapsibility index by point of care ultrasound for estimation of CVP: a comparative study with direct estimation of CVP. Open Access Emerg Med 2019;11:65-75
  2. Briegel J, Möhnle P. [nternational guidelines from the Surviving Sepsis Campaign: 2016 update. Anaesthesist 2017;66:530-8
  3. Hilbert-Carius P, Schwarzkopf D, Reinhart K, et al. Synthetic colloid resuscitation in severely injured patients: analysis of a nationwide trauma registry (TraumaRegister DGU). Sci Rep 2018;8:11567
  4. Haliloğlu M, Bilgili B, Kararmaz A, et al. The value of internal jugular vein collapsibility index in sepsis. Ulus Travma Acil Cerrahi Derg 2017;23:294-300
  5. Kent A, Patil P, Davila V, et al. Sonographic evaluation of intravascular volume status: Can internal jugular or femoral vein collapsibility be used in the absence of IVC visualization? Ann Thorac Med 2015;10:44-9
  6. Prekker ME, Scott NL, Hart D, et al. Point-of-care ultrasound to estimate central venous pressure: a comparison of three techniques. Crit Care Med 2013;41:833-41
  7. Bauman Z, Coba V, Gassner M, et al. Inferior vena cava collapsibility loses correlation with internal jugularvein collapsibility during increased thoracic or intra-abdominal pressure. J Ultrasound 2015;18:343- 8
  8. Diaztagle Fernández JJ, Rodríguez Murcia JC, Sprockel Díaz JJ. Venous-to-arterial carbon dioxide difference in the resuscitation of patients with severe sepsis and septic shock: A systematic review. Med Intensiva 2017;41:401-10
  9. Doucet JJ, Ferrada P, Murthi S, et al. Ultrasonographic inferior vena cava diameter response to trauma resuscitation after 1 hour predicts 24-hour fluid requirement. J Trauma Acute Care Surg 2020;88:70- 79
  10. Kaçar CK, Uzundere O, Yektaş A. A Two parameters for the evaluation of hypovolemia in patients with septic shock: inferior vena cava collapsibility index (IVCCI), Delta Cardiac Output. Med Sci Monit 2019;25:8105- 11
  11. Zhao J, Wang G. Inferior Vena Cava Collapsibility Index is a valuable and non-invasive index for elevated general heart end-diastolic volume index estimation in septic shock patients. Med Sci Monit 2016;22:3843-8
  12. Arican Ş, Dertli R, Dağli Ç, et al.The role of right ventricular volumes and inferior vena cava diameters inthe evaluation of volume status before colonoscopy. Turk J Med Sci 2019;49:1606-13
  13. Premkumar M, Rangegowda D, Kajal K, Khumuckham JS. Noninvasive estimation of intravascular vol