Dergiler / Annals of Medical Research / 2021 / Cilt: 28 - Sayı: 2

Fracture strength of endodontically treated teeth restored with novel CAD/CAM ceramic post systems

Sayfa
267–274
Yayın Tarihi
2022-10-12
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Results: While the FS values of GMzr (365.62 ± 28.52 N) was significantly higher than GFbr (261.07 ± 24.51 N), all other groups (167.09-191.64 N) significantly lower, according to the Tukey HSD (P

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Aim: The purpose of this study was to investigate the fracture strength (FS) and fracture types of endodontically treated teeth that restored with CAD/CAM made novel ceramic posts.Materials and Methods: Seventy human maxillary central incisors were selected, endodontically treated and expanded to 1.8 mm diameter with leaving of 2-3 mm canal filling.
📊
Temel Bulgular & Veri:The teeth were randomly divided into 7 post restoration groups (n=10); a glass fiber post system as control (GFbr), monolithic zirconia (GMzr), lithium disilicate (GLds), zirconia-reinforced lithium silicate (GZr_Lds) ceramics, nanoparticle-filled (GRmc_Cer), resin nano-ceramic (GRmc_Lu), and polymer-infiltrated (GRmc_En) resin matrix ceramic groups.
💡
Sonuç & Katkı:Results: While the FS values of GMzr (365.62 ± 28.52 N) was significantly higher than GFbr (261.07 ± 24.51 N), all other groups (167.09-191.64 N) significantly lower, according to the Tukey HSD (P
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Aim: The purpose of this study was to investigate the fracture strength (FS) and fracture types of endodontically treated teeth that restored with CAD/CAM made novel ceramic posts.Materials and Methods: Seventy human maxillary central incisors were selected, endodontically treated and expanded to 1.8 mm diameter with leaving of 2-3 mm canal filling. The teeth were randomly divided into 7 post restoration groups (n=10); a glass fiber post system as control (GFbr), monolithic zirconia (GMzr), lithium disilicate (GLds), zirconia-reinforced lithium silicate (GZr_Lds) ceramics, nanoparticle-filled (GRmc_Cer), resin nano-ceramic (GRmc_Lu), and polymer-infiltrated (GRmc_En) resin matrix ceramic groups. Then composite cores were build-up, crown restorations fabricated, and incubated in a water bath (37 ± 10C, 24 hours). A dynamic load was applied at 135° to the long axis of each specimen with a crosshead speed of 1 mm/min. FS and fracture types (favorable-catastrophic) were recorded. The FS values were statistically analyzed with one-way ANOVA and Tukey HSD tests (α=.05). Results: While the FS values of GMzr (365.62 ± 28.52 N) was significantly higher than GFbr (261.07 ± 24.51 N), all other groups (167.09-191.64 N) significantly lower, according to the Tukey HSD (P

🔖

Bu Makaleye Atıf Yap

SARIYILDIZ, E., DEDE, D. Ö., ÇELİK, E., ÇAKICI, F., ÇAKICI, E. B., TULGA, A., KAHVECİ, Ç. (2022). Fracture strength of endodontically treated teeth restored with novel CAD/CAM ceramic post systems. Annals of Medical Research, Cilt: 28 - Sayı: 2, 267–274. https://ajindex.com/articles/445729

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (16)

  1. Pontius O, Nathanson D, Giordano R, et al. Survival rate and fracture strength of incisors restored with different post and core systems and endodontically treated incisors without coronoradicular reinforcement. J Endod 2002;28:710-5
  2. Heydecke G, Butz F, Hussein A, et al. Fracture strength after dynamic loading of endodontically treated teeth restored with different post-and-core systems. J Prosthet Dent 2002;87:438-45
  3. Lamichhane A, Xu C, Zhang FQ. Dental fiber-post resin base material: a review. J Adv Prosthodont 2014;6:60- 5
  4. Pang J, Feng C, Zhu X, et al. Fracture behaviors of maxillary central incisors with flared root canals restored with CAD/CAM integrated glass fiber postand- core. Dent Mater J 2019;38:114-9
  5. Sary SB, Samah MS, Walid AZ. Effect of restoration technique on resistance to fracture of endodontically treated anterior teeth with flared root canals. J Biomed Res 2019;33:131-8
  6. Akkayan B, Gülmez T. Resistance to fracture of endodontically treated teeth restored with different post systems. J Prosthet Dent 2002;87:431-47
  7. Stankiewicz NR, Wilson PR. The ferrule effect: a literature review. Int Endod J 2002;35:575-81
  8. Maccari PC, Cosme DC, Oshima HM, et al. Fracture strength of endodontically treated teeth with flared root canals and restored with different post systems. J Esthet Restor Dent 2007;19:30-7
  9. Pereira JR, do Valle AL, Shiratori FK, et al. The effect of post material on the characteristic strength of fatigued endodontically treated teeth. J Prosthet Dent 2014;112:1225-30
  10. Bankoğlu Güngör M, Turhan Bal B, Yilmaz H, et al. Fracture strength of CAD/CAM fabricated lithium disilicate and resin nano ceramic restorations used for endodontically treated teeth. Dent Mater J 2017;36:135-41
  11. Ferrario VF, Sforza C, Serrao G, et al. Single tooth bite forces in healthy young adults. J Oral Rehabil 2004;31:18-22
  12. Ozcan N, Sahin E. In vitro evaluation of the fracture strength of all-ceramic core materials on zirconium posts. Eur J Dent 2013;7:455-60
  13. Dede DÖ, Armaganci A, Ceylan G, et al. Influence of abutment material and luting cements color on the final color of all ceramics. Acta Odontol Scand 2013;71:1570-8
  14. Ozkurt Z, Işeri U, Kazazoğlu E. Zirconia ceramic post systems: a literature review and a case report. Dent Mater J 2010 29:233-45
  15. Dikbas I, Tanalp J. An overview of clinical studies on fiber post systems. Scientific World Journal 2013;2013:171380
  16. Ray BC. Thermal shock and thermal fat