Dergiler / A|Z ITU Mimarlık Fakültesi Dergisi / 2021 / Cilt: 18 - Sayı: 3

In Situ dynamic system identification of historic masonry monuments based on non-destructive testing

Sayfa
637–651
Yayın Tarihi
2022-10-12
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The paper presents an in situ dynamic identification procedure of an historic masonry monument based on operational modal analysis and compares dynamic properties obtained from experimental and numerical studies and gives the results of FE model updating of the structure.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Istanbul is home to numerous architectural heritage which are in a great variety built by Byzantine and Ottoman period.
📊
Temel Bulgular & Veri:This article describes an experimental in-situ investigation of an 18th century historic masonry monument, Nur-u Osmaniye Mosque in Istanbul by the non-destructive testing.
💡
Sonuç & Katkı:The paper presents an in situ dynamic identification procedure of an historic masonry monument based on operational modal analysis and compares dynamic properties obtained from experimental and numerical studies and gives the results of FE model updating of the structure.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Istanbul is home to numerous architectural heritage which are in a great variety built by Byzantine and Ottoman period. On the other hand, cultural heritage buildings are faced with serious earthquake risks which require the investigation of the structural behaviour of cultural heritage buildings and the taking of necessary conservation measures to preserve and transfer them to the future in a sustainable way. This article describes an experimental in-situ investigation of an 18th century historic masonry monument, Nur-u Osmaniye Mosque in Istanbul by the non-destructive testing. Dynamic system identification study based on operational modal analysis (OMA) tests which include two different test setups in terms of locations and numbers of accelerometers. The extracted dynamic parameters of structure such as natural frequencies, mode shapes and as well as damping ratios obtained from two different test setups compared. In addition, the results of non-destructive in-situ tests used for the 3D Finite Element (FE) model updating by comparing and calibrating numerical and experimental characteristics. The paper presents an in situ dynamic identification procedure of an historic masonry monument based on operational modal analysis and compares dynamic properties obtained from experimental and numerical studies and gives the results of FE model updating of the structure.

🔖

Bu Makaleye Atıf Yap

KAHYA, Y., ÇILI, F., DABANLI, Ö. (2022). In Situ dynamic system identification of historic masonry monuments based on non-destructive testing. A|Z ITU Mimarlık Fakültesi Dergisi, Cilt: 18 - Sayı: 3, 637–651. https://ajindex.com/articles/426342

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (7)

  1. Ahmed Efendi (1918). Tarih-i Cami- i Şerif-i Nur-u Osmani. Tarih-i Osmani Encümeni Mecmuası İlavesi, 49, İstanbul:
  2. Dersaadet. Alvandi, A., & Cremona, C. (2006). Assessment of vibration-based damage identification techniques. Journal of Sound and Vibration, 292(1-2), 179–202. https://doi.org/10.1016/j. jsv.2005.07.036 Arıoğlu, E. & Arıoğlu, N. (1999). Mimar Sinan’ın yaygın olarak kullandığı küfeki taşının mühendislik gizemi. Mimar Sinan Dönemi Yapı Teknikleri Semineri, İstanbul.
  3. Arıoglu, N. and Arıoglu, E. (2005). Engineering mystery of master Architect Sinan’s “Kufeki” shell limestone. Architectural Science Review, 48, 163-172.
  4. ARTeMIS (2016). Ambient Response Testing and Modal Identification Software, Structural Vibration Solution A/S Aalborg, Denmark. www. svibs.com Baraccani, S., Palermo, M., Gasparini, G., Trombetti, T. (2021). A time domain approach for data interpretation from long‐term static monitoring of historical structures. Structural Control and Health Monitoring, 28:e2708. https://doi.org/10.1002/stc.2708
  5. Bartoli, G., Betti, M., & Giordano, S. (2013). In situ static and dynamic investigations on the “Torre Grossa” masonry tower. Engineering Structures, 52, 718–733. https://doi.org/10.1016/j. engstruct.2013.01.030 Binda, L., A. Saisi, and C. Tiraboschi. (2000). Investigation procedures for the diagnosis of historic masonries. Construction and Building Materials, 14(4), 199–233.
  6. Borlenghi, P., Gentile C., and Saisi A. (2021). Detecting and localizing anomalies on masonry towers from low-cost vibration monitoring, Smart Structures and Systems, 27(2), 319-333. https:// doi.org/10.12989/sss.2021.27.2.319 Brownjohn, J. M. W. (2007). Structural health monitoring of civil infrastructure. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 365(1851), 589–622. https://doi. org/10.1098/rsta.2006.1925
  7. Carpinteri, A., Invernizzi, S., & Lacidogna, G. (2005). In situ damage assessment and nonlinear modelling of a historical masonry tower. Engineering Structures. https://doi. org/10.1016/j.engstruct.2004.11.001 Chen, W.H., Lu, Z.R., Lin, W., Chen, S.H., Ni, Y.Q., Xia, Y., Liao, W.Y. (2011). Theoretical and experimental modal analysis of the Guangzhou New TV Tower. Engineering Structures, 33(12), 3628-3646. https://doi. org/10.1016/j.engstruct.2011.07.028. Costa, C., Arêde, A., Costa, A., Caetano, E., Cunha, Á., Magalhães, Filipe. (2015). Updating numerical models of masonry arch bridges by operational modal ana