Dergiler / Türk Göğüs Kalp Damar Cerrahisi Dergisi / 2003 / Cilt: 11 - Sayı: 2

Aort kök anevrizmalarında yeni sinüs oluşturularak kapak koruma

Valve sparing surgery using creation of a neosinus for aortic root aneurysms

Sayfa
79–84
Yayın Tarihi
2022-09-02
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Peroperatif mortalite 2 hastada (miyokard enfarktüsü ve mezentur embolisi) görüldü.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Asandan aort anevrizmalarında uygulanacak aort kapak resüspansiyon tekniğinde sinus Valsalva'lar rezeke edilir.
📊
Temel Bulgular & Veri:Bu ek girişim yaprakçık hareketlerini ve uzun dönem durabilitesini olumsuz etkileyebilir.
💡
Sonuç & Katkı:Bulgular: Peroperatif mortalite 2 hastada (miyokard enfarktüsü ve mezentur embolisi) görüldü.
🔬Tür:Araştırma Makalesi
📍Kapsam:2002 · 25 hasta
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Asandan aort anevrizmalarında uygulanacak aort kapak resüspansiyon tekniğinde sinus Valsalva'lar rezeke edilir. Bu ek girişim yaprakçık hareketlerini ve uzun dönem durabilitesini olumsuz etkileyebilir. Aort kapak yaprakçıklarının açılım ve kapanma karakteristikleri David ve neosinüs yaratılan modifikasyonlarında reimplantasyon sonrası karşılaştırdık. Materyal ve Metod: Eylül 1995 - Mayıs 2002 tarihleri arasında 25 hastaya David tekniği (Grup A) ve 24 hastaya modifiye neosinüs tekniği (Grup B) ile aort kök rekonstrüksiyonu uygulandı. Her iki grupta aort kapak muhafaza edilerek aort kökünün sentetik greft ile replasmanı sonrası suspense edildi ve koroner ostiumlar reimplante edildi. Transtorasik ve transözefageal çalışmalar intraoperatif, taburcu edilmeden önce ve 1 yıl sonra yapılarak üç grup karşılaştırıldı. Üçüncü bir grup kontrol grubu olarak (Grup C) ele alındı ve aort girişimi yapılmayan 25 hasta bu gruba dahil edildi. Bulgular: Peroperatif mortalite 2 hastada (miyokard enfarktüsü ve mezentur embolisi) görüldü. İki hastada strok gelişti. Yirmialtı hasta 12 ay takip edildi ve bunların 22 tanesi fonksiyonel kapasite I, iki tanesi II ve iki tanesi III. sınıfta idi. Üç hasta postoperatif dönemde kaybedildi. Altı hastada minimal, 4 hastada hafif ve bir hastada orta derecede aort yetmezliği saptandı. Tromboembolik olay görülmedi. Ortalama transvalvuler gradiyent 3.5 ± 2.2 mmHg idi. Kapak açılım velositesi Grup A'da 61.3 ± 20.1 cm/sn, Grup B'de 46.3 ± 8 cm/sn ve Grup C'de 29.2 ± 9.8 cm/sn idi (Grup A ile B arasındaki p = 0.003, Grup A ile C arasındaki p < 0.001, Grup B ile C arasındaki p < 0.001). Kapanma velositesi Grup A'da 57.5 ± 23 cm/sn, Grup B'de 43.8 ± 7 cm/sn ve Grup C'de 23.6 ± 7 cm/sn idi (Grup A ile B arasında p = 0.012, Grup A ile C arasındaki p < 0.001, Grup B ile C arasındaki p < 0.001). Grup A'daki 7 hastada nativ aort yaprakçıkları sistolde prostetik aort duvarına çarpıyordu. Sonuç: Nativ aort kapağının prostetik greft içerisine reimplantasyonu, anormal açılım ve kapanma hızlarına neden olur. Konvansiyonel tekniğine nazaran sinus bombesi yaratılması daha fizyolojik kapak dinamiklerine neden olur. Orta dönem klinik gözlemler her iki tip yöntemde olumlu sonuçlar verse de, kapak durabilitesini devam ettirecek daha fizyolojik yaprakçık dinamiklerinin hangi teknikte olacağı konusunda uzun dönem takip sonuçlarına ihtiyaç vardır.

Abstract

Background: Aortic valve resuspension for ascending aortic aneurysm repair is associated with removal of the sinus of Valsalva. This may cause changes in leaflet motion and thus impact on long term durability. We studied the opening and closing characteristics of the aortic valve leaflets after reimplantation by the technique described by T. David and a modification to create a "neosinus" compared to an age matched control group. Methods: Between September 1995 and May 2002, 25 patients underwent aortic root reconstruction as described by Tirone David (Group A). In 24 patients the technique was modified by shaping a "neosinus" (Group B). In both groups the native valve was preserved and suspended inside a tubular prosthesis with reimplantation of the coronary arteries. Transthoracic and transesophageal studies on aortic valve dynamics were performed intraoperatively, before hospital discharge and one year after surgery in all patients and compared to a separate group of 25 matched control individuals (Group C). Results: There was two perioperative deaths due to myocardial infarction and mesenterial emboli. Two patients suffered a stroke. Twentysix patients were followed up 12 months postoperatively. Twentytwo out of 26 patients were in NYHA functional class I, 2 patients in class II and the remaining 2 in class III. Three patients died in the postoperative period. Six patients had trivial AR, 4 had mild and 1 had moderate regurgitation. There were no thromboembolic events during follow up. The mean transvalvular gradient was 3.5 ± 2.2 mmHg. Valve opening velocity was 61.3 ± 20.1 cm/s in Group A, 46.3 ± 8 cm/s in Group B, and 29.2 ± 9.8 cm/s in Group C (Group A vs. B p = 0.003, A vs. Group C p < 0.001, B vs. C p < 0.001). Closing velocity was accelerated to 57.5 ± 23 cm/s in Group A and 43.8 ± 7 cm/s in Group B compared to 23.6 ± 7 cm/s in Group C (A vs B p = 0.012, A vs C p < 0.001, B vs C p = 0.002). In 7 patients of Group A the leaflets touched the prosthetic wall during systole. Conclusions: Reimplantation of the natural aortic valve in a prosthetic graft causes abnormally high opening and closing speeds with possibly increased stress. We could prove more physiologic valve dynamics after creation of a sinus bulge compared to the conventional reimplantation technique. Midterm clinical observation however showed favourable valve competence for both types of repair. Long term follow up is necessary to prove whether more physiologic leaflet dynamics lead to improved durability.

🔖

Bu Makaleye Atıf Yap

AYBEK, T., MORİTZ, A., DOĞAN, S. (2022). Aort kök anevrizmalarında yeni sinüs oluşturularak kapak koruma. Türk Göğüs Kalp Damar Cerrahisi Dergisi, Cilt: 11 - Sayı: 2, 79–84. https://ajindex.com/articles/425410

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (18)

  1. Halloran BG, Davis VA, McManus BM, Lynch TG, Baxter BT. Localization of aortic disease is associated with intrinsic differences in aortic structure. J Surg Res 1995;59:17-22
  2. Roman MJ, Rosen SE, Kramer-Fox R, Devereux RB. Prognostic significance of the pattern of aortic root dilatation in the Marfan syndrome. J Am Coll Cardiol 1993;22:1470-6
  3. Becker AE. Surgical and pathological anatomy of the aortic valve and root. Operative Techniques Card Thorac Surg 1996;1:3-14
  4. Bentall H, DeBono A. A technique for complete replacement of the ascending aorta. Thorax 1968;23:338-9
  5. Borst HG, Laas J. Surgical treatment of thoracic aortic aneurysms. Adv Cardiac Surg 1993;4:47-87
  6. Bachet J, Termingnon JL, Goutot B, et al. Aortic root replacement with a composite graft: Factors influencing immediate and long-term results. Eur J Cardiothorac Surg 1996;10:207-13
  7. David TE, Feindel CM. An aortic valve-sparing operation for patients with aortic incompetence and aneurysm of the ascending aorta. J Thorac Cardiovasc Surg 1992;103:617-22
  8. Sarsam MA, Yacoub M. Remodeling of the aortic valve annulus. J Thorac Cardiovasc Surg 1993;105:435-8
  9. David TE. Remodeling the aortic root and preservation of the native aortic valve. Op Tech Cardiac Thorac Surg 1996;1:44-56
  10. Van Son JAM, Battellini R, Mierzwa M, Walther T, Autschbach R, Mohr FW. Aortic root reconstruction with preservation of native aortic valve and sinuses in aortic root dilatation with aortic regurgitation. J Thorac Cardiovasc Surg 1999;117:1151-6
  11. Perry GJ, Helmcke F, Nanda NC, Byard C, Soto BL. Evaluation of aortic insufficiency by Doppler color flow mapping. J Am Coll Cardiol 1987;9:4:952-9
  12. Roman MJ, Devereux RB, Kramer-Fox R, O’Loughlin J. Two dimensional echocardiographic aortic root dimensions in normal children and adults. Am J Cardiol 1989;64:507-12
  13. Reid K. The anatomy of the sinus of Valsalva. Thorax 1970;25:79-85
  14. Brewer RJ, Deck JD, Capat ID, Nolan SP. The dynamic aortic root: It’s role in aortic valve function. J Thorac Cardiovasc Surg 1976;72:413-7
  15. Thubrikar MJ, Bosher LP, Nolan SP. The mechanism of opening of the aortic valve. J Thorac Cardiovasc Surg 1979;77:863-70
  16. Thubrikar MJ, Heckman JL, Nolan SP. High speed cineradiographic study of aortic valve leaflet motion. J Heart Valve Dis 1993;26:653-61
  17. Bellhouse BJ, Bellhouse FH. Mechanism of closure of the aortic valve. Nature 1968;217:86-7
  18. Thubrikar MJ, Nolan SP, Aoud J, Deck JD. Stress sharing bet