Dergiler / Türk Göğüs Kalp Damar Cerrahisi Dergisi / 2012 / Cilt: 20 - Sayı: 4

A comparision of endobronchial ultrasound-guided transbronchial needle aspiration and integrated positron emission tomography-computed tomography in the diagnosis of malignant mediastinal/hilar lymph nodes

Malign mediastinal ve hiler lenf nodlarının tanısında endobronş iyal ultrasonografi rehberliğinde yapılan transbronşiyal iğne aspirasyonunun ve pozitron emisyon tomografisi-bilgisayarlı tomografinin karşılaştırılması

Sayfa
843–849
Yayın Tarihi
2022-09-02
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Bulgular: Toplam 131 hastada 191 lenf nodu istasyonundan aspirasyon yapıldı.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Amaç: Bu çalışmanın amacı, entegre pozitron emisyon tomografisi- bilgisayarlı tomografi (PET-BT) ve endobronşiyal ultrasonografi rehberliğinde yapılan transbronşiyal iğne aspirasyonunun (EBUS-TBİA) malign mediastinal/hiler lenf nodlarının tanısındaki duyarlılığı, özgüllüğü ve tanı değerini saptamak ve birbirleri ile kıyaslamaktır.
📊
Temel Bulgular & Veri:Çalışma planı: Ekim 2008 - Nisan 2011 tarihleri arasında bilinen primer malignitesi veya malignite şüphesi olup, bilgisayarlı toraks tomografisinde büyümüş ve PET-BTde hipermetabolik hiler/mediastinal lenfnodu saptanan ve sitolojik tanı için EBUS-TBİA yapılmış 131 olgunun (96 erkek, 35 kadın; ort. yaş 58.3±8.4 yıl; dağılım 42-75) dosyası retrospektif olarak incelendi.
💡
Sonuç & Katkı:Bulgular: Toplam 131 hastada 191 lenf nodu istasyonundan aspirasyon yapıldı.
🔬Tür:Deneysel Tarla Denemesi
📍Kapsam:2008 · 131 hasta
⚙️Değişkenler:Alan Parametreleri

Özet

Amaç: Bu çalışmanın amacı, entegre pozitron emisyon tomografisi- bilgisayarlı tomografi (PET-BT) ve endobronşiyal ultrasonografi rehberliğinde yapılan transbronşiyal iğne aspirasyonunun (EBUS-TBİA) malign mediastinal/hiler lenf nodlarının tanısındaki duyarlılığı, özgüllüğü ve tanı değerini saptamak ve birbirleri ile kıyaslamaktır. Çalışma planı: Ekim 2008 - Nisan 2011 tarihleri arasında bilinen primer malignitesi veya malignite şüphesi olup, bilgisayarlı toraks tomografisinde büyümüş ve PET-BTde hipermetabolik hiler/mediastinal lenfnodu saptanan ve sitolojik tanı için EBUS-TBİA yapılmış 131 olgunun (96 erkek, 35 kadın; ort. yaş 58.3±8.4 yıl; dağılım 42-75) dosyası retrospektif olarak incelendi. EBUS-TBİA ile kesin tanı konulamayan olgulara mediastinoskopi/video yardımlı torakoskopik cerrahi (VYTC) gibi daha invazif girişimler uygulandı. PET-BTde malignite için standart maksimum alım (SUDmax) sınır değeri ≥3.0 olarak belirlendi. Malign mediastinal/hiler lenf nodlarının tanısında PET-BT ve EBUS-TBİAnın duyarlılık, özgüllük, tanı değeri ve negatif ve pozitif öngördürücü değerleri hesaplandı. Sonuçlar birbirleri ile karşılaştırıldı. Bulgular: Toplam 131 hastada 191 lenf nodu istasyonundan aspirasyon yapıldı. Yüz kırk iki malign lenf nodundan 134üne EBUS-TBİA ile malignite tanısı konulurken, 127sinin PET-BTde SUD max değerinin ≥3.0 olduğu görüldü. EBUS-TBİA ve PET-BTnin malign mediastinal ve hiler lenf nodlarının tanısındaki duyarlılık, özgüllük, tanı değeri ve negatif ve pozitif öngördürücü değerleri sırasıyla %94.3, %100, %95.8, %85.9, %100 ve %89.4, %18.3, %71.2, %37.5, %76.0 idi. EBUS-TBİA ve PET-BTnin birlikte kullanımı ile duyarlılık %100e ulaştı. Sonuç: EBUS-TBİAnın duyarlılık, özgüllük, tanı doğruluğu ve negatif öngördürücü değeri ve pozitif öngördürücü değeri PET-BTden daha yüksektir. Klasik bilgilere göre PET-BTnin yanlış pozitiflik oranının yüksek olması nedeni ile mediastinal evrelemede histolojik doğrulamasının yapılması gerekmektedir. EBUS-TBİA, PET-BT pozitif mediastinal/hiler lenf nodlarının histolojik doğrulamasında etkin, güvenilir ve minimal invasiv bir yöntemdir

Abstract

Background: In this study, we aimed to identify the sensitivity, specificity and diagnostic accuracy of integrated positron emission tomography- computed tomography (PET-CT) and endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in the diagnosis of malignant mediastinal/hilar lymph nodes and to compare with each other. Methods: Records of 131 patients (96 males, 35 females; mean age 58.3±8.4 years; range 42 to 75 years) with known primary or suspected malignancy who had enlarged and hypermetabolic hilar/mediastinal lymph nodes detected by thoracic CT and at PET-CT and in whom EBUS-TBNA performed for cytologic confirmation of the malignancy between October 2008 and April 2011 were retrospectively analyzed. More invasive procedures including mediastinoscopy/video-assisted thoracoscopic surgery (VATS) were performed in patients who did not receive definite diagnosis using EBUS- TBNA. The maximum standardised uptake value (SUVmax) cut-off level of PET-CT was considered ≥3.0. The sensitivity, specificity, diagnostic accuracy, and negative and positive predictive values of PET-CT and EBUS-TBNA in diagnosis of malignant hilar/mediastinal lymph nodes were calculated. The results were compared with each other. Results: A total of 191 lymph node stations of 131 patients were aspirated from the LN stations. Of the 142 lymph nodes, 134 were diagnosed with malignancy using EBUS-TBNA, while SUV max value was ≥3.0 in 127 by PET-CT. The sensitivity, spesificity, diagnostic accuracy, and negative and positive predictive values of EBUS-TBNA and PET-CT were 94.3%, 100%, 95.8%, 85.9%, 100% and 89.4%, 18.3%, 71.2%, 37.5%, 76.0%, respectively. With combined use of EBUS-TBNA and PET-CT, the sensitivity increased to 100%. Conclusion: The sensitivity, specificity, diagnostic accuracy, and negative predictive value and positive predictive value of EBUS-TBNA is higher than PET-CT. Based on conventional data, histological confirmation of PET-CT is necessary in mediastinal staging, due to high level of false positivity of PET-CT. EBUS-TBNA is an effective, reliable and minimally invasive method for histologic confirmation of PET-CT-positive malignant mediastinal/hilar lymph nodes.

🔖

Bu Makaleye Atıf Yap

DEMİRHAN, R., SALEPÇİ, B., ECE, D., FİDAN, A., DOĞAN, C., ŞENER, S. C., ÇAĞLAYAN, B. (2022). A comparision of endobronchial ultrasound-guided transbronchial needle aspiration and integrated positron emission tomography-computed tomography in the diagnosis of malignant mediastinal/hilar lymph nodes. Türk Göğüs Kalp Damar Cerrahisi Dergisi, Cilt: 20 - Sayı: 4, 843–849. https://ajindex.com/articles/424720

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Wallace MB, Block MI, Gillanders W, Ravenel J, Hoffman BJ, Reed CE, et al. Accurate molecular detection of non- small cell lung cancer metastases in mediastinal lymph nodes sampled by endoscopic ultrasound-guided needle aspiration. Chest 2005
  2. Shim SS, Lee KS, Kim BT, Chung MJ, Lee EJ, Han J, et al. Non-small cell lung cancer: prospective comparison of integrated FDG PET/CT and CT alone for preoperative staging. Radiology 2005
  3. Herth FJ, Eberhardt R, Krasnik M, Ernst A. Endobronchial ultrasound-guided transbronchial needle aspiration of lymph nodes in the radiologically and positron emission tomography-normal mediastinum in patients with lung cancer. Chest 2008
  4. Kuo CH, Chen HC, Chung FT, Lo YL, Lee KY, Wang CW, et al. Diagnostic value of EBUS-TBNA for lung cancer with non-enlarged lymph nodes: a study in a tuberculosis-endemic country. PLoS One 2011
  5. e16877. 5.Guhlmann A, Storck M, Kotzerke J, Moog F, Sunder- Plassmann L, Reske SN. Lymph node staging in non-small cell lung cancer: evaluation by [18F]FDG positron emission tomography (PET). Thorax 1997
  6. Gupta NC, Graeber GM, Bishop HA. Comparative efficacy of positron emission tomography with fluorodeoxyglucose in evaluation of small (_____1 cm), intermediate (1 to 3 cm), and large (>3 cm) lymph node lesions. Chest 2000
  7. Vansteenkiste JF, Stroobants SG, De Leyn PR, Dupont PJ, Verschakelen JA, Nackaerts KL, et al. Mediastinal lymph node staging with FDG-PET scan in patients with potentially operable non-small cell lung cancer: a prospective analysis of 50 cases. Leuven Lung Cancer Group. Chest 1997
  8. Rintoul RC, Skwarski KM, Murchison JT, Wallace WA, Walker WS, Penman ID. Endobronchial and endoscopic ultrasound-guided real-time fine-needle aspiration for mediastinal staging. Eur Respir J 2005
  9. Bury T, Paulus P, Dowlati A, Corhay JL, Weber T, Ghaye B, et al. Staging of the mediastinum: value of positron emission tomography imaging in non-small cell lung cancer. Eur Respir J 1996
  10. Kim YK, Lee KS, Kim BT, Choi JY, Kim H, Kwon OJ, et al. Mediastinal nodal staging of nonsmall cell lung cancer using integrated 18F-FDG PET/CT in a tuberculosis- endemic country: diagnostic efficacy in 674 patients. Cancer 2007
  11. Bakheet SM, Powe J. Benign causes of 18-FDG uptake on whole body imaging. Semin Nucl Med 1998
  12. Roberts PF, Follette DM, von Haag D, Park JA, Valk PE, Pounds TR, et al. Factors associ