Dergiler / Sigma Mühendislik ve Fen Bilimleri Dergisi / 2017 / Cilt: 35 - Sayı: 1

INFLUENCE OF CFRP ON THE STRENGTH OF RETROFITTED RC BEAMS WITHOUT STIRRUPS

Sayfa
77–85
Yayın Tarihi
2017-03-01
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

However, test results show that the retrofitting with CFRP increases the ductility of RC beams significantly even under such incompatibility.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Experimental investigations were conducted to study the behavior of reinforced concrete (RC) and steel fiber reinforced concrete (SFRC) beams retrofitted and strengthened with carbon fiber reinforced polymer (CFRP).
📊
Temel Bulgular & Veri:Four beams, each of which has a longitudinal reinforcement ratio of 1.34% and a shear span-to-effective depth ratio of 2.5, were tested under mid-span concentrated loads.
💡
Sonuç & Katkı:However, test results show that the retrofitting with CFRP increases the ductility of RC beams significantly even under such incompatibility.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:reinforced concrete · beam · carbon fiber reinforced polymer

Abstract

Experimental investigations were conducted to study the behavior of reinforced concrete (RC) and steel fiber reinforced concrete (SFRC) beams retrofitted and strengthened with carbon fiber reinforced polymer (CFRP). Four beams, each of which has a longitudinal reinforcement ratio of 1.34% and a shear span-to-effective depth ratio of 2.5, were tested under mid-span concentrated loads. The specimens consisted of a RC beam, a SFRC beam with 2.0% volume fraction of steel fibers and their companion beams that were loaded up to a certain damage level and then retrofitted with CFRP. The retrofitted beams were intentionally designed to be incompatible with the minimum requirements given by the code for FRP design. However, test results show that the retrofitting with CFRP increases the ductility of RC beams significantly even under such incompatibility.

🔖

Bu Makaleye Atıf Yap

ŞENGÜN, K., ARSLAN, G. (2017). INFLUENCE OF CFRP ON THE STRENGTH OF RETROFITTED RC BEAMS WITHOUT STIRRUPS. Sigma Mühendislik ve Fen Bilimleri Dergisi, Cilt: 35 - Sayı: 1, 77–85. https://ajindex.com/articles/415288

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. ACI Committee 318 (2008). Building Code Requirements for Structural Concrete, ACI, Farmington Hills, Mich
  2. ACI Committee 318 (2014). Building code requirements for structural concrete (ACI 318-14). Farmington Hills, MI, USA
  3. ACI Committee 440 (2008). Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures (ACI 440.2R-08). Farmington Hills, MI, USA
  4. ACI Committee 544 (1996). State-of-the-art report on fiber reinforced concrete (ACI 544.1R-96) (Reapproved 2009). Farmington Hills, MI, USA
  5. Alzate A., Arteaga A., Diego A. and Perera R. (2009), Shear strengthening of reinforced concrete beams using fibre reinforced polymers (FRP) European Journal of Environmental and Civil Engineering, 13(9), 1051-1060
  6. Arslan G (2014). Shear strength of steel fiber reinforced concrete (SFRC) slender beams. KSCE Journal of Civil Engineering 18(2): 587-594
  7. Arslan G, Keskin RSO, and Ulusoy S (2016) An experimental study on the shear strength of SFRC beams without stirrups. Construction and Building Materials (in review)
  8. Belarbi A, and Acun B (2013) FRP Systems in Shear Strengthening of Reinforced Concrete Structures, Procedia Engineering, Modern Building Materials, Structures and Techniques, Volume 57, 2013, Pages 2-8
  9. Bukhari IA, Vollum RL, Ahmad S, Sagaseta J.(2010) Shear strengthening of reinforced Concrete with CFRP. Magazine of Concrete Research, 62(1), 65–77
  10. Chaallal, O., Nollet, M., and Perraton, D. (1998). “Shear Strengthening of RC Beams by Externally Bonded Side CFRP Strips.” J. Compos. Constr., 10.1061/(ASCE)1090-0268(1998)2:2(111), 111-113
  11. CNR DT 200, “Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Existing Structures”, Rome, 2004, Italy
  12. Khalifa A and Nanni A (2000) Improving shear capacity of existing RC T-section beams using CFRP composites. Cement and Concrete Composites 22(2): 165-174
  13. Khalifa, A., Gold, W., Nanni, A., and M.I., A. (1998). “Contribution of Externally Bonded FRP to Shear Capacity of RC Flexural Members.” J. Compos. Constr., 10.1061/(ASCE)1090-0268(1998)2:4(195), 195-202
  14. Lima JLT and Barros JAO (2007), Design models for shear strengthening of reinforced concrete beams with externally bonded frp composites: a statistical vs reliability approach, FRPRCS-8 University of Patras, Patras, Greece, July 16-18
  15. Menegotto M, Monti G and Liotta MA (2009), Modelling Shear Mechanisms in FRP-Streng