Dergiler / Laparoscopic Endoscopic Surgical Science / 2020 / Cilt: 27 - Sayı: 4

Anterior abdominal wall hernia repair with e-TEP technique: A single-center experience with short term results

Sayfa
259–265
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Placing the meshes in the extraperitoneal area may also prevent the development of mesh-related complications from its contact with intraperitoneal organs.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Introduction: Ventral hernia repair is one of the most common surgical procedures performed by surgeons.
📊
Temel Bulgular & Veri:Materials and Methods: Between June 2019 and February 2020, 18 patients with ventral hernia were operated on by the same surgeon using the e-TEP technique and were reviewed retrospectively.
💡
Sonuç & Katkı:Placing the meshes in the extraperitoneal area may also prevent the development of mesh-related complications from its contact with intraperitoneal organs.
🔬Tür:Literatür & Derleme Çalışması
📍Kapsam:2019 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

Introduction: Ventral hernia repair is one of the most common surgical procedures performed by surgeons. Extended-view totally extraperitoneal (e-TEP) hernia repair is an emerging surgical technique that can be applied in the surgical treatment of ventral hernias. We present our experience of an e-TEP technique with the corresponding short-term results. Materials and Methods: Between June 2019 and February 2020, 18 patients with ventral hernia were operated on by the same surgeon using the e-TEP technique and were reviewed retrospectively. Patients diagnosed with diastasis recti defect ≥2 cm with concomitant umbilical hernia were included in the study. Results: A total of 18 cases underwent eTEP until February 2020. Out of 18 patients, 10 (55.5%) were male while eight (44.5%) were female. The mean age was 46.4 years (29–68), mean body mass index (BMI) was 25.7 kg/m2 (18.7–30.8 kg/m2 ), average hospitalization time was 1.78 days (1–3 days), average ASA score was 1.7 (1–2), mean operation time was 145 minute (100–298 min.), and mean mesh area used was 266 cm2 . Cyanoacrylate glue (Liquiband®Fix8™) was used to fix the mesh to the peritoneum in 14 patients, while no fixation method was used in 4 patients. None of the cases underwent open surgery. No recurrence was detected during the follow-up, with a maximum of 12 months and a minimum of 4 months (mean 8.3 months). Conclusion: e-TEP is a safe and feasible emerging surgical technique for primary or incisional ventral hernia repairs. This new approach that has all the advantages of laparoscopic surgery allows flexible port insertion and the closure of defects by allowing large size mesh placement in the retromuscular area. Placing the meshes in the extraperitoneal area may also prevent the development of mesh-related complications from its contact with intraperitoneal organs.

🔖

Bu Makaleye Atıf Yap

ERTEM, M., BABÜR, T., ÖZVERİ, E. (2020). Anterior abdominal wall hernia repair with e-TEP technique: A single-center experience with short term results. Laparoscopic Endoscopic Surgical Science, Cilt: 27 - Sayı: 4, 259–265. https://ajindex.com/articles/415058

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (14)

  1. Vorst AL, Kaoutzanis C, Carbonell AM, Franz MG. Evolution and advances in laparoscopic ventral and incisional hernia repair. World J Gastrointest Surg 2015
  2. 293−305. [CrossRef] 2. Cobb WS, Kercher KW, Heniford BT. Laparoscopic repair of incisional hernias. Surg Clin North Am 2005
  3. 91−103. [CrossRef] 3. Penchev D, Kotashev G, Mutafchiyski V. Endoscopic enhancedview totally extraperitoneal retromuscular approach for ventral hernia repair. Surg Endosc 2019
  4. 3749−56. [CrossRef] 4. Poulose BK, Shelton J, Phillips S, Moore D, Nealon W, Penson D, et al. Epidemiology and cost of ventral hernia repair: making the case for hernia research. Hernia 2012
  5. 179−83. [CrossRef] 5. Jin J, Rosen MJ. Laparoscopic versus open ventral hernia repair. Surg Clin North Am 2008
  6. 100, viii. [CrossRef] 6. Nguyen MT, Berger RL, Hicks SC, Davila JA, Li LT, Kao LS, et al. Comparison of outcomes of synthetic mesh vs suture repair of elective primary ventral herniorrhaphy: a systematic review and meta-analysis. JAMA Surg 2014
  7. 415−21. [CrossRef] 7. LeBlanc KA, Booth WV. Laparoscopic repair of incisional abdominal hernias using expanded polytetrafluoroethylene: preliminary findings. Surg Laparosc Endosc 1993
  8. 39−41. 8. Deshpande RK, Talwar S. A novel laparoscopic approach: (eTEP) technique in ventral abdominal hernia-our experience. International Journal of Surgery Science 2019
  9. 22−5. [CrossRef] 9. Wake BL, McCormack K, Fraser C, Vale L, Perez J, Grant AM. Transabdominal pre-peritoneal (TAPP) vs totally extraperitoneal (TEP) laparoscopic techniques for inguinal hernia repair. Cochrane Database Syst Rev 2005
  10. CD004703. [CrossRef] 10. Reynvoet E, Deschepper E, Rogiers X, Troisi R, Berrevoet F. Laparoscopic ventral hernia repair: is there an optimal mesh fixation technique? A systematic review. Langenbecks Arch Surg 2014
  11. 55−63. [CrossRef] 11. Daes J. The enhanced view-totally extraperitoneal technique for repair of inguinal hernia. Surg Endosc 2012
  12. 1187−9. 12. Belyansky I, Daes J, Radu VG, Balasubramanian R, Reza Zahiri H, Weltz AS, et al. A novel approach using the enhanced-view totally extraperitoneal (eTEP) technique for laparoscopic retromuscular hernia repair. Surg Endosc 2018
  13. 1525−32. 13. Köhler G, Kaltenböck R, Pfandner R, Dauser B, Lechner M. Precostal top-down extended totally extraperitoneal ventral hernia plasty (eTEP): simplification of a complex technical approach. Hernia 2020
  14. 527−35. [CrossRef] 14. Shakya VC, Byanjankar B, Pandit R, Pangeni A,