Dergiler / Turkish journal of vascular surgery / 2021 / Cilt: 30 - Sayı: 1

Comparing near-infrared spectroscopy monitoring and stump pressure measurement to estimate the need for shunting during carotid artery endarterectomy

Sayfa
13–20
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: Our study results show that near-infrared spectroscopy can demonstrate much more precise results than stump pressure measurement in predicting the need for shunting to prevent perioperative major neurological complications after carotid cross-clamping during carotid endarterectomy.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objectives: In this study, we aimed to evaluate and compare the cerebral oximetry monitoring with near-infrared spectroscopy and the mean stump pressure measurement for the decision of shunting after carotid artery cross-clamping during carotid endarterectomy.
📊
Temel Bulgular & Veri:Patients and methods: Between January 2015 and October 2017, a total of 42 patients (33 males, 9 females; mean age 71.3±8.5 years; range, 56 to 92 years) who underwent carotid endarterectomy were retrospectively analyzed.
💡
Sonuç & Katkı:Conclusion: Our study results show that near-infrared spectroscopy can demonstrate much more precise results than stump pressure measurement in predicting the need for shunting to prevent perioperative major neurological complications after carotid cross-clamping during carotid endarterectomy.
🔬Tür:Araştırma Makalesi
📍Kapsam:2015 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

Objectives: In this study, we aimed to evaluate and compare the cerebral oximetry monitoring with near-infrared spectroscopy and the mean stump pressure measurement for the decision of shunting after carotid artery cross-clamping during carotid endarterectomy. Patients and methods: Between January 2015 and October 2017, a total of 42 patients (33 males, 9 females; mean age 71.3±8.5 years; range, 56 to 92 years) who underwent carotid endarterectomy were retrospectively analyzed. The patients were divided into shunting/non-shunting groups and patients with postoperative major neurological complications/without complications groups. Results: Carotid artery cross-clamping caused a significant decrease in regional cerebral oxygen saturation (rSO2) in the shunting group (p=0.01), while the contralateral remained stable (p=0.121). The mean ipsilateral rSO2 reduction was 35% in the shunting group and only 6.6% in the non-shunting group (p=0.019). Postoperative hemiplegia developed in three (7.1%) patients in the shunting group whose ipsilateral rSO2 was not reduced during cross-clamping, despite the mean stump pressure was reduced (p=0.03). Conclusion: Our study results show that near-infrared spectroscopy can demonstrate much more precise results than stump pressure measurement in predicting the need for shunting to prevent perioperative major neurological complications after carotid cross-clamping during carotid endarterectomy.

🔖

Bu Makaleye Atıf Yap

DEŞER, S. B. (2021). Comparing near-infrared spectroscopy monitoring and stump pressure measurement to estimate the need for shunting during carotid artery endarterectomy. Turkish journal of vascular surgery, Cilt: 30 - Sayı: 1, 13–20. https://ajindex.com/articles/414605

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. North American Symptomatic Carotid Endarterectomy Trial Collaborators, Barnett HJM, Taylor DW, Haynes RB, Sackett DL, Peerless SJ, et al. Beneficial effect of carotid endarterectomy in symptomatic patients with high-grade carotid stenosis. N Engl J Med 1991;325:445- 53
  2. Hıdıroğlu M, Çetin L, l Kunt A, Karakişi O, Küçüker A, Şener E. Early results of carotid endarterectomy for carotid artery diseases. Turk Gogus Kalp Dama 2010;18:190-5
  3. MRC European Carotid Surgery Trial: interim results for symptomatic patients with severe (70-99%) or with mild (0-29%) carotid stenosis. European Carotid Surgery Trialists' Collaborative Group. Lancet 1991;337:1235-43
  4. Yamane K, Shima T, Okada Y, Nishida M. Hemodynamic evaluation by using near infrared spectroscopy during carotid endarterectomy. J Stroke Cerebrovasc Dis 1999;8:211-6 5. Pugliese F, Ruberto F, Tosi A, Martelli S, Bruno K, Summonti D, et al. Regional cerebral saturation versus transcranial Doppler during carotid endarterectomy under regional anaesthesia. Eur J Anaesthesiol 2009;26:643-7
  5. Toraman, Fevzi T. The role of monitorization of regional cerebral oxygen saturation in adult cardiac surgery. GogusKalp-Damar Anestezi ve Yogun Bakim Dernegi Dergisi 2010;16:82-95
  6. Aksun M, Girgin S, Kuru V, Şencan A, Yılık L, Aran G, et al. Cerebral oximetry monitoring method for the evaluation of the need of shunt placement during carotid endarterectomy. Turk Gogus Kalp Dama 2013;21:1152-5
  7. Carlin RE, McGraw DJ, Calimlim JR, Mascia MF. The use of near-infrared cerebral oximetry in awake carotid endarterectomy. J Clin Anesth 1998;10:109-13
  8. Naylor AR, Ricco JB, de Borst GJ, Debus S, de Haro J, Halliday A, et al. Editor's Choice- Management of Atherosclerotic Carotid and Vertebral Artery Disease: 2017 Clinical Practice Guidelines of the European Society for Vascular Surgery (ESVS). Eur J Vasc Endovasc Surg 2018;55:3-81
  9. Kuroda S, Houkin K, Abe H, Hoshi Y, Tamura M. Nearinfrared monitoring of cerebral oxygenation state during carotid endarterectomy. Surg Neurol 1996;45:450-8
  10. Hoshi Y, Tamura M. Dynamic multichannel near-infrared optical imaging of human brain activity. J Appl Physiol (1985) 1993;75:1842-6
  11. McCormick PW, Stewart M, Goetting MG, Dujovny M, Lewis G, Ausman JI. Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics. Crit Care Med 1991;19:89-97
  12. Pennekamp CW, Immink RV, den Ruijter HM, Kappelle LJ, Bots ML, Buhre WF, et al. Near-infra