Dergiler / Diagnostic and Interventional Radiology / 2021 / Cilt: 27 - Sayı: 6

Percutaneous retrieval of a Mobin-Uddin inferior vena cava filter 42 years following implantation

Sayfa
792–795
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

She was successfully treated with thrombolysis, thrombectomy, endobronchial forceps assisted IVCF removal, and iliocaval stent reconstruction.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Inferior vena cava filters (IVCFs) are an established alternative for protection from thromboembolism when anticoagulation fails or is contraindicated.
📊
Temel Bulgular & Veri:We present a 53-year-old patient with a Mobin-Uddin permanent IVCF placed 42 years prior, complicated by acute iliocaval thrombosis following more than 40 years of filter dwell time.
💡
Sonuç & Katkı:She was successfully treated with thrombolysis, thrombectomy, endobronchial forceps assisted IVCF removal, and iliocaval stent reconstruction.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Inferior vena cava filters (IVCFs) are an established alternative for protection from thromboembolism when anticoagulation fails or is contraindicated. Before the creation of retrievable IVCFs, patients received filters that were permanent or designed without standardized retrieval options. Although these filters were implanted for prolonged protection, chronic vena caval occlusion and post-thrombotic syndrome are potential sequelae. We present a 53-year-old patient with a Mobin-Uddin permanent IVCF placed 42 years prior, complicated by acute iliocaval thrombosis following more than 40 years of filter dwell time. She was successfully treated with thrombolysis, thrombectomy, endobronchial forceps assisted IVCF removal, and iliocaval stent reconstruction.

🔖

Bu Makaleye Atıf Yap

PATEL, R., AHUJA, A., RESNICK, S. (2021). Percutaneous retrieval of a Mobin-Uddin inferior vena cava filter 42 years following implantation. Diagnostic and Interventional Radiology, Cilt: 27 - Sayı: 6, 792–795. https://ajindex.com/articles/413745

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (2)

  1. Mobin-Uddin K, McLean R, Jude JR. A new catheter technique of interruption of inferior vena cava for prevention of pulmonary embolism. Am Surg 1969; 35:889–894
  2. Mobin-Uddin K, McLean R, Bolooki H, Jude JR. Caval interruption for prevention of pulmonary embolism: long-term results of a new method. Arch Surg 1969; 99:711–715. [Crossref] 3. Jia Z, Wu A, Tam M, Spain J, McKinney JM, Wang W. Caval penetration by inferior vena cava filters: a systematic literature review of clinical significance and management. Circulation 2015; 132:944–952. [Crossref] 4. Athanasoulis CA, Kaufman JA, Halpern EF, Waltman AC, Geller SC, Fan CM. Inferior vena caval filters: review of a 26-year single-center clinical experience. Radiology 2000; 216:54–66. [Crossref] 5. Hann CL, Streiff MB. The role of vena caval filters in the management of venous thromboembolism. Blood Rev 2005; 19:179–202. [Crossref] 6. Harlal A, Ojha M, Johnston KW. Vena cava filter performance based on hemodynamics and reported thrombosis and pulmonary embolism patterns. J Vasc Interv Radiol 2007; 18:103–115. [Crossref] 7. Fox MA, Kahn SR. Post thrombotic syndrome in relation to vena cava filter placement: a systematic review. J Vasc Interv Radiol 2008; 19:981–985. [Crossref] 8. Workman C, Desai K, Karp J, Lewandowski R. Advanced retrieval techniques in the removal of permanent inferior vena cava filters. J Vasc Interv Radiol 2016; 27:S287. [Crossref]