⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: For the prediction of optimal CPAP titration pressure in OSAS treatment, wide neck and waist circumferences, high hypopharyngeal collapse score and retropalatal and retrolingual lateral wall collapse grades may be determinative.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:clinical parameters, and pulmonary respiratory function on the therapeutic titration pressure of continuous positive airway pressure (CPAP) device in obstructive sleep apnea syndrome (OSAS).
📊
Temel Bulgular & Veri:Methods: The study comprised 41 OSAS patients whose optimum CPAP titration pressures were measured.
💡
Sonuç & Katkı:Conclusion: For the prediction of optimal CPAP titration pressure in OSAS treatment, wide neck and waist circumferences, high hypopharyngeal collapse score and retropalatal and retrolingual lateral wall collapse grades may be determinative.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

clinical parameters, and pulmonary respiratory function on the therapeutic titration pressure of continuous positive airway pressure (CPAP) device in obstructive sleep apnea syndrome (OSAS). Methods: The study comprised 41 OSAS patients whose optimum CPAP titration pressures were measured. Each patient underwent an otorhinolaryngologic and thoracic examination, and data was recorded for height, weight, body mass index, neck-waist circumferences, Mallampati classification, tonsillar hypertrophy, hypopharyngeal collapse, soft palate-tongue base obstruction scores, peak nasal inspiratory flow and acoustic rhinometry measures, and CPAP device therapeutic pressures. Forced vital capacity, forced expiratory volume, FEV1/FVC ratio and peak expiratory flow values were noted. Results: Median CPAP optimal pressure cut-off value was determined as 9 mmH2O. Statistical analysis was made in two groups as CPAP titration optimal pressure ≤9 and >9 mmH2O. In the optimal pressure >9 group, neck and waist circumferences, hypopharyngeal collapse score, retropalatal and retrolingual lateral wall collapse scores were significantly higher (p<0.05). In multivariate and univariate model analysis, neck and waist circumferences, hypopharyngeal collapse score, retropalatal and retrolingual lateral wall collapse scores were observed to be significant in predicting high and low pressures in univariate model. Conclusion: For the prediction of optimal CPAP titration pressure in OSAS treatment, wide neck and waist circumferences, high hypopharyngeal collapse score and retropalatal and retrolingual lateral wall collapse grades may be determinative.

🔖

Bu Makaleye Atıf Yap

KIRGEZEN, T., BİLİCİ, S., ÇAKIR, M., CHASAN, M., YİĞİT, Ö., CEYRAN, Ö. (2020). Factors Affecting Optimal Titration Pressure of Continuous Positive Airway Pressure Device in Patients with Obstructive Sleep Apnea Syndrome. Turkish archives of otorhinolaryngology, Cilt: 58 - Sayı: 2, 80–86. https://ajindex.com/articles/403347

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Young T, Palta M, Dempsey J, Skatrud J, Weber S, Badr S. The occurrence of sleep-disordered breathing among middle-aged adults. N Engl J Med 1993
  2. [Crossref] 2. Sullivan CE, Issa F, Berthon-Jones M, Eves L. Reversal of obstructive sleep apnoea by continuous positive airway pressure applies through the nares. Lancet 1981
  3. [Crossref] 3. Engleman HM, Kingshott RN, Wraith PK, Mackay TW, Deary IJ, Douglas NJ. Randomized placebo-controlled crossover trial of continuous positive airway pressure for mild sleep apnea/hypopnea syndrome. Am J Resp Crit Care Med 1999
  4. [Crossref] 4. ATS statement. Indications and standards for use of nasal continuous positive airway pressure (CPAP) in sleep apnea syndromes. Am J Resp Crit Care Med 1994
  5. [Crossref] 5. Oksenberg A, Arons E, Froom P. Does the severity of obstructive sleep apnea predict patients requiring high continuous positive airway pressure? Laryngoscope 2006
  6. [Crossref] 6. The American Academy of Sleep Medicine (AASM) Guidelines. (Access date: June 7th, 2020). https://aasm.org/clinical-resources/practice-standards/practice-guidelines/ 7. Kezirian EJ, Hohenhorst W, de Vries N. Drug-induced sleep endoscopy: the VOTE classification. Eur Arch Otorhinolaryngol 2011
  7. [Crossref] 8. Miljeteig H, Hoffstein V. Determinants of continuous positive airway pressure level for the treatment of obstructive sleep apnea. Am Rev Respir Dis 1993
  8. [Crossref] 9. Hoffstein V, Mateika S. Predicting nasal continuous positive pressure. Am Rev Respir Dis. 1993
  9. [Crossref] 10. Sforza E, Krieger J, Bacon W, Petiau C, Zamagni M, Boudewijns A. Determinants of effective continuous positive airway pressure in obstructive sleep apnea. Role of respiratory effort. Am J Respir Crit Care Med 1995
  10. [Crossref] 11. Lin IF, Chuang ML, Liao YF, Chen NH, Li HY. Predicting effective continuous positive airway pressure in Taiwanese patients with obstructive sleep apnea syndrome. J Formos Med Assoc 2003
  11. Stradling JR, Hardinge M, Paxton J, Smith DM. Relative accuracy of algorithm-based prescription of nasal CPAP in OSA. Resp Med 2004
  12. [Crossref] 13. Lankford A, Proctor C, Richard R. Continuous positive airway pressure changes in bariatric surgery patients undergoing rapid weight loss. Obes Surg 2005
  13. [Crossref] 14. Pahkala R, Seppä J, Ikonen A, Smirnov G, Tuomilehto H. The impact of pharyngeal fat tissue on the