Dergiler / Celal Bayar Üniversitesi Fen Bilimleri Dergisi / 2022 / Cilt: 18 - Sayı: 1

Boron Removal from Colemanite Mine Wastewater by Coagulation using Zinc Hydroxide―A Factorial Optimization Study

Sayfa
77–83
Yayın Tarihi
2022-03-25
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The used material and process was promising for boron mine wastewater.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:In this study, boron removal from synthetic solutions and colemanite mine wastewater by coagulation method using in-situ generated zinc hydroxide from zinc chloride salt was investigated.
📊
Temel Bulgular & Veri:The parameters for Jar test experiments were solution pH (8-12), concentration (50-750 mg/L), temperature (12-40oC), and zinc chloride dosage (1.0204-10.204 g).
💡
Sonuç & Katkı:The used material and process was promising for boron mine wastewater.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Boron removal · coagulation · colemanite mine wastewater

Abstract

In this study, boron removal from synthetic solutions and colemanite mine wastewater by coagulation method using in-situ generated zinc hydroxide from zinc chloride salt was investigated. The parameters for Jar test experiments were solution pH (8-12), concentration (50-750 mg/L), temperature (12-40oC), and zinc chloride dosage (1.0204-10.204 g). The saturation pH of zinc hydroxide is 8.93. The boron adsorption capacity reached to maximum value at pH value of 9 and this pH was selected as optimum value. Boron adsorption capacity increased with increasing concentration due to increasing driving force of concentration. High dosages increased the removal percentage. The adsorption of boron to zinc hydroxide had exothermic nature. The optimum conditions obtained from synthetic solutions were applied to the colemanite mine wastewater by 22 factorial design. The maximum boron adsorption capacity of zinc hydroxide from colemanite mine wastewater was calculated as 43.57 mg/g. The used material and process was promising for boron mine wastewater.

🔖

Bu Makaleye Atıf Yap

KORKMAZ, M., ÖZMETİN, C., OZMETİN, E., ÇALGAN, E., ZİYANAK, Ö. (2022). Boron Removal from Colemanite Mine Wastewater by Coagulation using Zinc Hydroxide―A Factorial Optimization Study. Celal Bayar Üniversitesi Fen Bilimleri Dergisi, Cilt: 18 - Sayı: 1, 77–83. https://ajindex.com/articles/383986

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Korkmaz, M., Özmetin, C., and Fil, B.A. 2016. Modelling of Boron Removal from Solutions Using Purolite S 108 in a Batch Reactor. CLEAN–SoilAir Water; 44: 949–958
  2. Vanlı, Ö. 2007. Removal of Pb, Cd, B Elements From Soil By Chelate Assisted Phytoremediation Method. Istanbul Technical University, Institute of Science and Technology, Master in Science Thesis, Istanbul
  3. Bayar, D. 2001. Boron removal from aqueous solution by adsorption and experimental design”,Osman Gazi University, Institute of Science and Technology, Master in ScienceThesis, Eskişehir
  4. Korkmaz, M., Fil, B.A., Özmetin, C., and Yaşar, Y. 2014. Full factorial design of experiments for boron removal from Colemanite mine wastewater using Purolite S 108 resin. Bulgarian Chemical Communucations; 46:594–601
  5. Özmetin, C., Aydın, Ö., Kocakerim, M.M., Korkmaz, M., and Özmetin, E. 2009. An empirical kinetic model for calcium removal from calcium impurity-containing saturated boric acid solution by ion exchange technology using Amberlite IR–120 resin. Chemical Engineering Journal; 148: 420–424
  6. Yılmaz, A.E. 2009. The Boron Removal from industrial wastewater by electrocoagulation method”, Atatürk University, Institute of Science and Technology, Ph.D. Thesis, Erzurum
  7. Dural, E. 1998. Researching of production wastes of borax and boric acid fabrics of Etibank in Bandırma area bletoused in glaze composition (1000 oC-1200 oC). Anadolu University, Institute of Science and Technology, Master in Science Thesis, Eskişehir
  8. Kutlu, M., Aydoğan, G., and Mumcu, E. 2007. Mutagenicity analysis of water samples from Seydisuyu (Kırka, Turkey) stream under the influence of boron production complex, Food and Chemical Toxicology; 45:2064–2068
  9. Yilmaz, A.E., Boncukcuoğlu, R., Kocakerim, M.M., Yilmaz, M.T., and Paluluoğlu, C. 2008. Boron removal from geothermal waters by Electrocoagulation. Journal of Hazardous Materials; 153:146–151
  10. Kluczka, J., Ciba, J., Trojanowska, J., Zolotajkin, M., Turek, M., and Dydo, P. 2007. Removal of boron dissolved in water. Environmental Progress; 26:71–77
  11. Öztürk, N., and Köse, T.E. 2008. Boron removal from aqueous solutions by ion-exchange resin: Batch studies. Desalination; 227: 233–240
  12. Na, J.W., and Lee, K.J., 1993. Characteristics of boronbadsorption on strong-base anion-exchange resin. Annals of Nuclear Energy; 20;455–462
  13. Sayiner, G., Kandemirli, F., and Dimoglo, A. 2008. Evaluation of boron removal by electrocoagulation using iron a