Yapay Zeka Hızlı Bakış & Çıkarımlar
AI Insight⚡ TL;DR(1 Cümlede Hızlı Çıkarım)
It was shown that the defect structure of peak 1 is based on colloid centers, $Ti^{+4}-3O_2^-$ mixed centers and $U_1$-centers.
📌 3 Maddede Bu Makale
🎯
Amaç & Hipotez:The possible defect structure of peak 1 of LiF:Mg,Ti (TLD-100) was studied in the present work after different pre-irradiation heat treatments between 80°C and 150°C using the computer glow curve deconvolution (CGCD) method.
📊
Temel Bulgular & Veri:The possible defect structure of peak 1 of LiF:Mg,Ti (TLD-100) was studied in the present work after different pre-irradiation heat treatments between 80°C and 150°C using the computer glow curve deconvolution (CGCD) method.
💡
Sonuç & Katkı:It was shown that the defect structure of peak 1 is based on colloid centers, $Ti^{+4}-3O_2^-$ mixed centers and $U_1$-centers.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri
Özet
The possible defect structure of peak 1 of LiF:Mg,Ti (TLD-100) was studied in the present work after different pre-irradiation heat treatments between 80°C and 150°C using the computer glow curve deconvolution (CGCD) method. It was shown that the defect structure of peak 1 is based on colloid centers, $Ti^{+4}-3O_2^-$ mixed centers and $U_1$-centers.
🔖
Bu Makaleye Atıf Yap
YAZICI, A. N. (2002). Defect structure of glow peak 1 in LiF: Mg, Ti (TLD-100). Turkish Journal of Physics, Cilt: 26 - Sayı: 6, 473–481. https://ajindex.com/articles/378484