Dergiler / Turkish journal of emergency medicine (Online) / 2015 / Cilt: 15 - Sayı: 1

Comparison of Conventional Radiography and Digital Computerized Radiography in Patients Presenting to Emergency Department

Sayfa
8–12
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Although the initial cost of setup of digital CR and PACS service is high at the emergency department, we think that Digital CR is more cost-effective than conventional radiography for emergency departments in the long-term

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:ObjectivesTo compare the differences between conventional radiography and digital computerized radiography (CR) in patients presenting to the emergency department.MethodsThe study enrolled consecutive patients presenting to the emergency department who needed chest radiography.
📊
Temel Bulgular & Veri:Quality score of the radiogram was assessed with visual analogue score (VAS100 mm), measured in terms of millimeters and recorded at the end of study.
💡
Sonuç & Katkı:Although the initial cost of setup of digital CR and PACS service is high at the emergency department, we think that Digital CR is more cost-effective than conventional radiography for emergency departments in the long-term
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

ObjectivesTo compare the differences between conventional radiography and digital computerized radiography (CR) in patients presenting to the emergency department.MethodsThe study enrolled consecutive patients presenting to the emergency department who needed chest radiography. Quality score of the radiogram was assessed with visual analogue score (VAS100 mm), measured in terms of millimeters and recorded at the end of study. Examination time, interpretation time, total time, and cost of radiograms were calculated.ResultsThere were significant differences between conventional radiography and digital CR groups in terms of location unit (Care Unit, Trauma, Resuscitation), hour of presentation, diagnosis group, examination time, interpretation time, and examination quality. Examination times for conventional radiography and digital CR were 45.2 and 34.2 minutes, respectively. İnterpretation times for conventional radiography and digital CR were 25.2 and 39.7 minutes, respectively. Mean radiography quality scores for conventional radiography and digital CR were 69.1 mm and 82.0 mm. Digital CR had a 1.05 TL cheaper cost per radiogram compared to conventional radiography.ConclusionsSince interpretation of digital radiograms is performed via terminals inside the emergency department, the patient has to be left in order to interpret the digital radiograms, which prolongs interpretation times. We think that interpretation of digital radiograms with the help of a mobile device would eliminate these difficulties. Although the initial cost of setup of digital CR and PACS service is high at the emergency department, we think that Digital CR is more cost-effective than conventional radiography for emergency departments in the long-term

🔖

Bu Makaleye Atıf Yap

ÖZÇETE, E., BOYDAK, B., ERSEL, M., KIYAN, G. S., UZ, İ., ÇEVRİM, Ö. (2015). Comparison of Conventional Radiography and Digital Computerized Radiography in Patients Presenting to Emergency Department. Turkish journal of emergency medicine (Online), Cilt: 15 - Sayı: 1, 8–12. https://ajindex.com/articles/373982

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (8)

  1. Ovitt TW, Christenson PC, Fisher HD 3rd, Frost MM, Nudelman S, Roehrig H, et al. Intravenous angiography using digital vid- eo subtraction: x-ray imaging system. AJR Am J Roentgenol 1980;135:1141-4. Moore R. Computed radiography. Med Electron 1980;11:78-9. Advent of digital radiography: Part 1 BS Verma, IK Indrajit In- dian J Radiol Imaging /May 2008/Vol 18/Issue 2. Schaefer-Prokop CM, Prokop M. Storage phosphor radiogra- phy. Eur Radiol 1997;7 Suppl 3:58-65.
  2. Busch HP, Lehmann KJ, Drescher P, Georgi M. New chest im- aging techniques: a comparison of five analogue and digital methods. Eur Radiol 1992;2:335-41.
  3. Andriole KP, Luth DM, Gould RG. Workflow assessment of dig- ital versus computed radiography and screen-film in the out- patient environment. J Digit Imaging 2002;15 Suppl 1:124-6.
  4. Reiner BI, Siegel EL. Technologists' productivity when using PACS: comparison of film-based versus filmless radiography. AJR Am J Roentgenol 2002;179:33-7.
  5. Dalla Palma L, Grisi G, Cuttin R, Rimondini A. Digital vs con- ventional radiography: cost and revenue analysis. Eur Radiol 1999;9:1682-92.
  6. Pathi R, Langlois S. Evaluation of the effectiveness of digi- tal radiography in emergency situations. Australas Radiol 2002;46:167-9. Andriole KP. Productivity and cost assessment of computed radiography, digital radiography, and screen-film for out- patient chest examinations. Journal of Digital Imaging 2002;15:161-9. Commission of the European Communities a - Radiation Pro- tection Programme. CEC Quality Criteria for Diagnostic Ra- diographic Images and Patient Exposure Trial. CAATS-INSERM EUR 12952. (1989). Busch HP. Digital radiography for clinical applications. Eur Ra- diol 1997;7 Suppl 3:66-72.
  7. Ramli K, Abdullah BJ, Ng KH, Mahmud R, Hussain AF. Comput- ed and conventional chest radiography: a comparison of im- age quality and radiation dose. Australas Radiol 2005;49:460-6. van Soldt RT, Zweers D, van den Berg L, Geleijns J, Jansen JT, Zoetelief J. Survey of posteroanterior chest radiography in The Netherlands: patient dose and image quality. Br J Radiol 2003;76:398-405.
  8. Dalla Palma L, Grisi G, Cuttin R, Rimondini A. Digital vs con- ventional radiography: cost and revenue analysis. Eur Radiol 1999;9:1682-92.