Investigation of Forces and Stresses Acting on a Shoulder-Hand System Considering Strains in Muscles

Sayfa
1–8
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

It is also necessary to take into account the stress fluctuations in the human body during various daily activities; fluctuating stresses acting on an implant may create fatigue cracks at the shoulder end of the humerus in addition to a high stress concentration factor due to shape and size changes in the humerus bone.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:A model is proposed to investigate the forces and stresses acting on bones in a shoulder-hand system due to straining of muscles during daily physical activities.
📊
Temel Bulgular & Veri:The stress is found to increase from the elbow end of the humerus bone toward the shoulder end.
💡
Sonuç & Katkı:It is also necessary to take into account the stress fluctuations in the human body during various daily activities; fluctuating stresses acting on an implant may create fatigue cracks at the shoulder end of the humerus in addition to a high stress concentration factor due to shape and size changes in the humerus bone.
🔬Tür:Modelleme & Sayısal Simülasyon
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Biomechanical modeling · Humerus bone · Stresses on shoulder-hand system

Özet

A model is proposed to investigate the forces and stresses acting on bones in a shoulder-hand system due to straining of muscles during daily physical activities. This model is proposed as a truss system consisting of beams, or rods, corresponding to the considered bones and muscles, connected by frictionless joints. One of the hard loading positions, which occurs when one does pull-ups while holding onto a bar (a common fitness activity), is considered in the proposed model as an example. The stress is found to increase from the elbow end of the humerus bone toward the shoulder end. The stress in the example study reached a maximum value of approximately 8000 N/cm2 near the shoulder end during the pull-up motion, which is about 20% less than the maximum stress calculated when the straining of muscles was neglected. The difference between these 2 maximum values of stress indicates the effect of strained muscles, which was first taken into consideration in this study. This stress value is considerably high when the strength of bones is taken into account. It is also necessary to take into account the stress fluctuations in the human body during various daily activities; fluctuating stresses acting on an implant may create fatigue cracks at the shoulder end of the humerus in addition to a high stress concentration factor due to shape and size changes in the humerus bone.

Abstract

A model is proposed to investigate the forces and stresses acting on bones in a shoulder-hand system due to straining of muscles during daily physical activities. This model is proposed as a truss system consisting of beams, or rods, corresponding to the considered bones and muscles, connected by frictionless joints. One of the hard loading positions, which occurs when one does pull-ups while holding onto a bar (a common fitness activity), is considered in the proposed model as an example. The stress is found to increase from the elbow end of the humerus bone toward the shoulder end. The stress in the example study reached a maximum value of approximately 8000 N/cm2 near the shoulder end during the pull-up motion, which is about 20% less than the maximum stress calculated when the straining of muscles was neglected. The difference between these 2 maximum values of stress indicates the effect of strained muscles, which was first taken into consideration in this study. This stress value is considerably high when the strength of bones is taken into account. It is also necessary to take into account the stress fluctuations in the human body during various daily activities; fluctuating stresses acting on an implant may create fatigue cracks at the shoulder end of the humerus in addition to a high stress concentration factor due to shape and size changes in the humerus bone.

🔖

Bu Makaleye Atıf Yap

ABDULALIYEV, Z., ÇELİK, Ö., GÖLLER, G., KAYALI, E. S. (2007). Investigation of Forces and Stresses Acting on a Shoulder-Hand System Considering Strains in Muscles. Turkish Journal of Engineering and Environmental Sciences, Cilt: 31 - Sayı: 1, 1–8. https://ajindex.com/articles/369094

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (19)

  1. Alexander, M.N., “Principles of Animal Locomotion”, Princeton: Princeton University Press, 2002.
  2. An, Y.H. and Draughn, R.A., ed., “Mechanical Testing of Bone and the Bone-Implant Interface”, CRC Press,
  3. Boca Raton, FL, USA, 2000.
  4. Anglin, C., Tolhurst, P., Wyss, U.P. and Pichora, D.R., “Glenoid Cancellous Bone Strength and Modulus”, Journal of Biomechanics, 32, 1091-1098, 1999.
  5. Anglin, C., Wyss, U.P. and Pichora, D.R., “Shoulder Prosthesis Subluxation: Theory and Experiment”, J Shoulder Elbow Surg, 9, 104-14, 2000.
  6. Au, A.G., Raso, V.J., Liggins, A.B., Otto, D.D., Amirfazli, A., “A Three-Dimensional Finite Element Stress Analysis for Tunnel Placement and Buttons in Anterior Cruciate Ligament Reconstructions”, Journal of Biomechanics, 38, 827-832, 2005.
  7. Belyaev, N.M., “Strength of Materials”, The Governmental Publishing of Technical and Theoretical Literature, Moscow, 1953.
  8. Cowin, S.C., ed., “Bone Mechanics”, CRC Press,
  9. Boca Raton, FL, 1989.
  10. Currey, J.D., “Bones: Structure and Mechanics”, Princeton University Press, Oxford, 2002.
  11. Debski, R.E., Weiss, J.A., Newman, W.J., Moore, S.M. and McMahon, P.J., “Stress and Strain in the Anterior Band of the Inferior Glenohumeral Ligament during a Simulated Clinical Examination”, J Shoulder Elbow Surg., 14 (Issue 1, Suppl 1): S24- S31, 2005.
  12. Fung, Y.C., “Biomechanics: Motion, Flow, Stress, and Growth”, Springer-Verlag, New York, 1990.
  13. Gielo-Perczak, K., and Leamon T., “An Investigation of the Individual Differences in Geometry of the Glenohumeral Joint on the Maximum Acceptable Workload” In 4th Meeting of the International Shoulder Group, Cleveland, OH, 2002.
  14. Gordon, D. and Robertson, E., “Introduction to Biomechanics for Human Motion Analysis”, Waterloo Biomechanics, 1997.
  15. Kirsch, R.F. and Acosta A.M., “Model-Based Development of Neuroprostheses for Restoring Proximal Arm Function”, In 4th Meeting of the International Shoulder Group, Cleveland, OH, 2002.
  16. Liebowitz, H., ed., “Fracture an Advanced Treatise in Fracture of Nonmetals and Composites”, Academic Press, New York, 1972.
  17. Linde, F., Hvid, I. and Madsen, F., “The Effect of Specimen Geometry on the Mechanical Behaviour of Trabecular Bone Specimens”, Journal of Biomechanics, 25, 359-368, 1992.
  18. Martens, M., Van Audekercke, R., Delport, P., De Meester, P. and Mulier, J.C., “The Mechanical Characteristics of Cancellous Bone at the Upper Femoral Region”, Journal of Biomechanics, 16, 971-983, 1983.
  19. Oosterom, R., van der Helm, F.C.T., Herder, J.L. and Bersee, H.E.N., “Analyt