Dergiler / The Anatolian Journal of Cardiology / 2021 / Cilt: 25 - Sayı: 10

Outcomes of intracutaneous sutures in comparison with intracutaneous staples in cardiac implantable-electronic device pocket closure

Sayfa
716–720
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Conclusion: The rate of early wound problems is higher using intracutaneous sutures; and therefore, intracutaneous staples should be preferred to prevent these problems.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: With the increase in cardiovascular implantable-electronic devices (CIEDs), complications from insertion and healing are also increasing.
📊
Temel Bulgular & Veri:Group 1 included patients with pocket closure using intracutaneous sutures; whereas in Group 2, the pocket was closed by intracutaneous staples.
💡
Sonuç & Katkı:Conclusion: The rate of early wound problems is higher using intracutaneous sutures; and therefore, intracutaneous staples should be preferred to prevent these problems.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Objective: With the increase in cardiovascular implantable-electronic devices (CIEDs), complications from insertion and healing are also increasing. Therefore, the objective of this study was to compare the intracutaneous stapling method to the absorbable suture technique in terms of complications, procedure time, and pocket closure time. Methods: An observational study was conducted over the course of three months on patients with CIED implantation. The patients were divided in two groups according to pocket closure technique. Group 1 included patients with pocket closure using intracutaneous sutures; whereas in Group 2, the pocket was closed by intracutaneous staples. Data were collected regarding patient characteristics and wound problems. The endpoints were wound problems, including early and late wound problems (primary), total procedure time, and the time taken for pocket closure (secondary). Results: One hundred and nineteen patients and 107 patients were allocated to Group 1 and Group 2, respectively. During the three-month observation period, 27 (22.6%) patients in Group 1 and 13 (12.1%) patients in Group 2 suffered from early wound problems, and the combined primary endpoint reached was statistically significant (p=0.021). Minor and major bleeding events were more common in Group 1 [Odds ratio (OR): 4.49, p=0.024; OR: 0.96, p=0.052]. The time to close the pocket was markedly reduced in Group 2 (7.29±1.42 vs. 3.98±1.19, p<0.001). Conclusion: The rate of early wound problems is higher using intracutaneous sutures; and therefore, intracutaneous staples should be preferred to prevent these problems.

🔖

Bu Makaleye Atıf Yap

MALİK, J., JAVED, N., RANA, G., SHOAİB, M., ISHAQ, U., CHAUHAN, H. (2021). Outcomes of intracutaneous sutures in comparison with intracutaneous staples in cardiac implantable-electronic device pocket closure. The Anatolian Journal of Cardiology, Cilt: 25 - Sayı: 10, 716–720. https://ajindex.com/articles/366635

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (3)

  1. Bhatia N, El-Chami M. Leadless pacemakers: a contemporary review. J Geriatr Cardiol 2018; 15: 249-53
  2. Kotsakou M, Kioumis I, Lazaridis G, Pitsiou G, Lampaki S, Papaiwannou A, et al. Pacemaker insertion. Ann Transl Med 2015; 3: 42
  3. Datta G. Pacemaker pocket infection rate and suture technique. Turk Kardiyol Dern Ars 2020; 48: 44-8. [Crossref] 4. De Maria E. New skin closure system facilitates wound healing after cardiovascular implantable electronic device surgery. World J Clin Cases 2015; 3: 675-7. [Crossref] 5. Spencker S, Coban N, Koch L, Schirdewan A, Mueller D. Comparison of skin adhesive and absorbable intracutaneous suture for the implantation of cardiac rhythm devices. Europace 2011; 13: 416-20. [Crossref] 6. Przybylski A, Derejko P, Kwaśniewski W, Urbańczyk-Swić D, Zakrzewska J, Orszulak W, et al. Bleeding complications after pacemaker or cardioverter-defibrillator implantation in patients receiving dual antiplatelet therapy: Results of a prospective, two-centre registry. Neth Heart J 2010; 18: 230-5. [Crossref] 7. Kim MJ, Park BY, Hong SE, Kang SR. Abstract: Effect of Absorbable Skin Stapler in Autologous Breast Reconstruction Patients: Approach Through Economic and Cosmesis. Plast Reconstr Surg Glob Open 2016; 4 (9 Suppl): 203. [Crossref] 8. Duteille F, Rouif M, Alfandari B, Andreoletti JB, Sinna R, Laurent B, et al. Reduction of skin closure time without loss of healing quality: a multicenter prospective study in 100 patients comparing the use of Insorb absorbable staples with absorbable thread for dermal suture. Surg Innov 2013; 20: 70-3. [Crossref]