Dergiler / The Anatolian Journal of Cardiology / 2017 / Cilt: 17 - Sayı: 6

Directly ventricular septal defect closure without using arteriovenous wire loop: Our adult case series using transarterial retrograde approach

Sayfa
461–468
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The only limitation in adult patients is delivery sheath length.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: The standard transcatheter ventricular septal defects (VSD) closure procedure is established with arteriovenous (AV) loop and is called as antegrade approach.
📊
Temel Bulgular & Veri:The directly retrograde transarterial VSD closure without using AV loop might be better option as shortens the procedure time and decreases radiation exposure.Methods: Our series consist of twelve sequential adult cases with congenital VSDs (seven with perimembranous, four with muscular, one with postoperative residuel VSD).
💡
Sonuç & Katkı:The only limitation in adult patients is delivery sheath length.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

Objective: The standard transcatheter ventricular septal defects (VSD) closure procedure is established with arteriovenous (AV) loop and is called as antegrade approach. The directly retrograde transarterial VSD closure without using AV loop might be better option as shortens the procedure time and decreases radiation exposure.Methods: Our series consist of twelve sequential adult cases with congenital VSDs (seven with perimembranous, four with muscular, one with postoperative residuel VSD). The mean age was 26.9 (Range 18-58), the mean height was 168.75 cm (Range 155-185cm), and the mean body mass index was 23.4 (Range 17.3-28.4). Maximum and minimum defect sizes were 10 and 5 mm and the mean defect size was 6.24 mm. The procedure was performed with left heart catheterization and advancing the delivery sheath over the stiff exchange wire then VSD occlusion from left side.Results: The defects were successfully closed with this technique in eleven patients. In sixth patient, the defect could not be cannulated by the delivery sheath, as the tip of the sheath did not reach the defect and VSD was closed with same sheath by standard transvenous approach using AV loop. We didn\'t encounter any complication releated to semilunar or atrioventricular valves. Atrioventricular conduction system was not affected by the procedure in any patients. The median procedure and fluoroscopy times were 66 and 16.5 minutes respectively.Conclusion: Transarterial retrograde VSD closure without using AV loop simplifies the procedure, decreases the radiation exposure, and shortens the procedure time. The only limitation in adult patients is delivery sheath length.

🔖

Bu Makaleye Atıf Yap

PEKEL, N., ERCAN, E., ÖZPELİT, M. E., ÖZYURTLU, F., YILMAZ, A., TOPALOĞLU, C., SAYGI, S., YAKAN, S., TENGİZ, İ. (2017). Directly ventricular septal defect closure without using arteriovenous wire loop: Our adult case series using transarterial retrograde approach. The Anatolian Journal of Cardiology, Cilt: 17 - Sayı: 6, 461–468. https://ajindex.com/articles/365832

Kaynakça (11)

  1. Thanopoulos BD, Tsaousis GS, Konstadopoulou GN, Zarayelyan AG. Transcatheter closure of muscular ventricular septal defects with the Amplatzer ventricular septal defect occluder: initial clinical application in children. J Am Coll Cardiol 1999; 33: 1395-9
  2. Qin Y, Chen J, Zhao X, Liao D, Mu R, Wang S, et al. Transcatheter closure of perimembranous ventricular septal defect using a modified double-disk occluder. Am J Cardiol 2008; 101: 1781-6
  3. Yang J, Yang L, Wan Y, Zuo J, Zhang J, Chen W, et al. Transcatheter device closure of perimembranous ventricular septal defects: midterm outcomes. Eur Heart J 2010; 31: 2238-45
  4. Esteves CA, Solarewicz LA, Cassar R, Neves JR, Esteves V, Arrieta R. Occlusion of the perimembranous ventricular septal defect using Cera devices. Catheter Cardiovasc Interv 2012; 80: 182-7
  5. Holzer R, Balzer D, Cao QL, Lock K, Hijazi ZM; Amplatzer Muscular Ventricular Septal Defect Investigators. Device closure of muscular ventricular septal defects using the Amplatzer muscular ventricular septal defect occluder: immediate and mid-term results of a U.S. registry. J Am Coll Cardiol 2004; 43: 1257-63
  6. Carminati M, Butera G, Chessa M, De Giovanni J, Fisher G, Gewillig M, et al; Investigators of the European VSD Registry. Transcatheter closure of congenital ventricular septal defects: results of the European Registry. Eur Heart J 2007; 28: 2361-8
  7. Hijazi ZM, Hakim F, Al-Fadley F, Abdelhamid J, Cao QL. Transcatheter closure of single muscular ventricular septal defects using the amplatzer muscular VSD occluder: initial results and technical considerations. Catheter Cardiovasc Interv 2000; 49: 167-72
  8. Arora R, Trehan V, Kumar A, Kalra GS, Nigam M. Transcatheter closure of congenital ventricular septal defects: experience with various devices. J Interv Cardiol 2003; 16: 83-91
  9. Szkutnik M, Kusa J, Białkowski J. Percutaneous closure of perimembranous ventricular septal defects with Amplatzer occluders-a single centre experience. Kardiol Pol 2008; 66: 941-7. 10 Jameel AA, Arfi AM, Arif H, Amjad K, Omar GM. Retrograde approach for device closure of muscular ventricular septal defects in children and adolescents, using the Amplatzer muscular ventricular septal defect occluder. Pediatr Cardiol 2006; 27: 720-8
  10. Muthusamy K. Retrograde closure of perimembranous ventricular septal defect using muscular ventricular septal occluder: a singlecenter experience of a novel technique. Pediatr Cardiol 2015; 36: 106-10
  11. Koneti NR, Pen