Dergiler / The Anatolian Journal of Cardiology / 2019 / Cilt: 22 - Sayı: 1

Is trans-radial approach related to an increased risk of radiation exposure in patients who underwent diagnostic coronary angiography or percutaneous coronary intervention? (The SAKARYA study)

Sayfa
5–12
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Compared to femoral access, diagnostic CA via radial access was not related toan increased radiation exposure. (Anatol J Cardiol 2019; 22: 5-12)

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: It is still debatable whether diagnostic coronary angiography (CA) or percutaneous coronary interventions (PCIs) increase radiationexposure when performed via radial approach as compared to femoral approach.
📊
Temel Bulgular & Veri:This question was investigated in this study by comparison ofdose-area product (DAP), reference air kerma (RAK), and fluoroscopy time (FT) among radial and femoral approaches.Methods: All coronary procedures between November 2015 and November 2017 were assessed; and 4215 coronary procedures were enrolledin the study.
💡
Sonuç & Katkı:Compared to femoral access, diagnostic CA via radial access was not related toan increased radiation exposure. (Anatol J Cardiol 2019; 22: 5-12)
🔬Tür:Araştırma Makalesi
📍Kapsam:2015 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

Objective: It is still debatable whether diagnostic coronary angiography (CA) or percutaneous coronary interventions (PCIs) increase radiationexposure when performed via radial approach as compared to femoral approach. This question was investigated in this study by comparison ofdose-area product (DAP), reference air kerma (RAK), and fluoroscopy time (FT) among radial and femoral approaches.Methods: All coronary procedures between November 2015 and November 2017 were assessed; and 4215 coronary procedures were enrolledin the study. Patients with bifurcation, chronic total occlusion, cardiogenic shock, or prior coronary artery bypass surgery were excluded. These4215 procedures were evaluated for three different categories: diagnostic CA (Group I), PCI in patients with stable angina (Group II), and PCI inpatients with ACS (Group III).Results: Age was significantly higher in the femoral arm of all groups. Among patients in the radial arm of Groups I and II, males were overrepresented. Therefore, a multiple linear regression analysis with stepwise method was performed. After adjusting these clinical confounders,there was no significant difference with regard to DAP, RAK, and FT between femoral and radial access in Group I. In contrast, PCI via radialaccess was significantly associated with increased DAP, RAK, and FT in Groups II and III.Conclusion: In spite of an increased experience with trans-radial approach, PCI of coronary lesions via radial route was associated with arelatively small but significant radiation exposure in our study. Compared to femoral access, diagnostic CA via radial access was not related toan increased radiation exposure. (Anatol J Cardiol 2019; 22: 5-12)

🔖

Bu Makaleye Atıf Yap

ÜREYEN, Ç. M., COŞANSU, K., VURAL, M. G., ŞAHİN, S. E., KOCAYİĞİT, İ., PABUCCU, M. T., AKSOY, M. N. M., AĞAÇ, M. T., TATLI, E., GÜNDÜZ, H., AKDEMİR, R. (2019). Is trans-radial approach related to an increased risk of radiation exposure in patients who underwent diagnostic coronary angiography or percutaneous coronary intervention? (The SAKARYA study). The Anatolian Journal of Cardiology, Cilt: 22 - Sayı: 1, 5–12. https://ajindex.com/articles/365760

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (10)

  1. Romagnoli E, Biondi-Zoccai G, Sciahbasi A, Politi L, Rigattieri S, Pendenza G, et al. Radial versus femoral randomized investigation in ST-segment elevation acute coronary syndrome: the RIFLE-STEACS (Radial Versus Femoral Randomized Investigation in ST-Elevation Acute Coronary Syndrome) study. J Am Coll Cardiol 2012; 60: 2481-9
  2. Valgimigli M, Gagnor A, Calabro P, Frigoli E, Leonardi S, Zaro T, et al. Radial versus femoral access in patients with acute coronary syndromes undergoing invasive management: a randomised multicentre trial. Lancet 2015; 385: 2465-76
  3. Mitchell MD, Hong JA, Lee BY, Umscheid CA, Bartsch SM, Don CW. Systematic review and cost-benefit analysis of radial artery access for coronary angiography and intervention. Circ Cardiovasc Qual Outcomes 2012; 5: 454-62
  4. Bertrand OF, Belisle P, Joyal D, Costerousse O, Rao SV, Jolly SS, et al. Comparison of transradial and femoral approaches for percutaneous coronary interventions: a systematic review and hierarchical Bayesian meta-analysis. Am Heart J 2012; 163: 632-48
  5. Roguin A, Goldstein J, Bar O, Goldstein JA. Brain and neck tumors among physicians performing interventional procedures. Am J Cardiol 2013; 111: 1368-72
  6. Buchanan GL, Chieffo A, Mehilli J, Mikhail GW, Mauri F, Presbitero P, et al. The occupational effects of interventional cardiology: results from the WIN for Safety survey. EuroIntervention 2012; 8: 658-63
  7. Marinskis G, Bongiorni MG, Dagres N, Lewalter T, Pison L, BlomstromLundqvist C; Scientific Initiative Committee, European Heart Rhythm Association. X-ray exposure hazards for physicians performing ablation procedures and device implantation: results of the European Heart Rhythm Association survey. Europace 2013; 15: 444–6
  8. Karatasakis A, Brilakis HS, Danek BA, Karacsonyi J, MartinezParachini JR, Nguyen-Trong PJ, et al. Radiation-associated lens changes in the cardiac catheterization laboratory: Results from the IC-CATARACT (CATaracts Attributed to RAdiation in the CaTh lab) study. Catheter Cardiovasc Interv 2018; 91: 647-54
  9. Heidbuchel H, Wittkampf FH, Vano E, Ernst S, Schilling R, Picano E, et al. Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological procedures. Europace 2014; 16: 946-64
  10. Miller DL, Balter S, Cole PE, Lu HT, Schueler BA, Geisinger M, et al.; RAD-IR study. Radiation doses in interventional radiology procedures: The RAD-IR study Part I. Overall measures of dose. J Vasc Interv