Dergiler / The Anatolian Journal of Cardiology / 2018 / Cilt: 20 - Sayı: 3

Electroanatomic mapping-guided pediatric catheter ablation with limited/zero fluoroscopy

Sayfa
159–164
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Therecurrence rate was 5.1% (4/78) at follow-up.Conclusion: Fluoroscopy can be completely eliminated in most pediatric catheter ablation procedures with the use of mapping systems byachieving high acute success rates and acceptable low complication rates.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: The use of fluoroscopy in pediatric catheter ablation has decreased because of mapping systems.
📊
Temel Bulgular & Veri:In this study, we present the efficiencyand reliability of the electroanatomic mapping system in nonfluoroscopic pediatric catheter ablation.Methods: The medical records of patients aged <18 years who underwent ablation between November 2016 and April 2018 were evaluated.Fluoroscopy was not used in cases involving ablation of right sided-arrhythmia foci.
💡
Sonuç & Katkı:Therecurrence rate was 5.1% (4/78) at follow-up.Conclusion: Fluoroscopy can be completely eliminated in most pediatric catheter ablation procedures with the use of mapping systems byachieving high acute success rates and acceptable low complication rates.
🔬Tür:Araştırma Makalesi
📍Kapsam:2016 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

Objective: The use of fluoroscopy in pediatric catheter ablation has decreased because of mapping systems. In this study, we present the efficiencyand reliability of the electroanatomic mapping system in nonfluoroscopic pediatric catheter ablation.Methods: The medical records of patients aged <18 years who underwent ablation between November 2016 and April 2018 were evaluated.Fluoroscopy was not used in cases involving ablation of right sided-arrhythmia foci. Fluoroscopy was used only for trans-septal puncture orretroaortic approach/coronary angiography.Results: A total of 76 patients underwent catheter ablation for 78 supraventricular and ventricular tachyarrhythmia substrates under the guidanceof EnSite Velocity system. Fluoroscopy was used in only 14 (18.4%) of these substrates. The mean fluoroscopy duration in these 14 procedureswas 5.4±3.15 min. No complications were noted, except a temporary right bundle branch block in one patient and pericardial effusionin another following cryoablation. The acute success rate in achieving complete elimination of arrhythmia substrates was 97.4% (76/78). Therecurrence rate was 5.1% (4/78) at follow-up.Conclusion: Fluoroscopy can be completely eliminated in most pediatric catheter ablation procedures with the use of mapping systems byachieving high acute success rates and acceptable low complication rates.

🔖

Bu Makaleye Atıf Yap

KOCA, S., PAÇ, F. A., ERİŞ, D., ZABUN, M. M., ÖZEKE, Ö., ÖZCAN, F. (2018). Electroanatomic mapping-guided pediatric catheter ablation with limited/zero fluoroscopy. The Anatolian Journal of Cardiology, Cilt: 20 - Sayı: 3, 159–164. https://ajindex.com/articles/365333

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (4)

  1. von Alvensleben JC, Dick M 2nd, Bradley DJ, LaPage MJ. Transseptal access in pediatric and congenital electrophysiology procedures: defining risk. J Interv Card Electrophysiol 2014; 41: 273-7.
  2. Law IH, Fischbach PS, LeRoy S, Lloyd TR, Rocchini AP, Dick M. Access to the left atrium for delivery ofradiofrequency ablation in young patients: retrograde aortic vs transseptal approach. Pediatr Cardiol 2001; 22: 204-9. [CrossRef] Parvez B, Pathak V, Schubert CM, Wood M. Comparison of lesion sizes produced by cryoablation and open irrigation radiofrequency ablation catheters. J Cardiovasc Electrophysiol 2008; 19: 528- 34. [CrossRef] Karadeniz C, Akdeniz C, Turan O, Tuzcu V. Cryoablation of septal accessory pathways in children: midterm results. Pacing Clin Electrophysiol 2014; 37: 1095-9. [CrossRef] Silver ES, Silva JN, Ceresnak SR, Chiesa NA, Rhee EK, Dubin AM, et al. Cryoablation with an 8-mm-tip catheter for pediatric atrioventricular nodal reentrant tachycardia is safe and efficacious with a low incidence of recurrence. Pacing Clin Electrophysiol 2010; 33: 681-6. [CrossRef] Miyake CY, Mah DY, Atallah J, Oikle HP, Melgar ML, Alexander ME, et al. Nonfluoroscopic imaging systems reduce radiation exposure in children undergoing ablation of supraventricular tachycardia. Heart Rhythm 2011; 8: 519-25. [CrossRef] Gist K, Tigges D, Smith G, Clark J. Learning curve for zero fluoroscopy catheter ablation of AVNRT: Early versus late experience. Pacing Clin Electrophysiol 2011; 34: 264-8. [CrossRef] Tuzcu V. Significant reduction of fluoroscopy in pediatric catheter ablation procedures: Long-term experience from a single center. Pacing Clin Electrophysiol 2012; 35: 1067-73. [CrossRef] Papagiannis J, Avramidis D, Alexopoulos C, Kirvassilis G. Radiofrequency ablation of accessory pathways in children and congenital heart disease patients: impact of a nonfluoroscopic navigation system. Pacing Clin Electrophysiol 2011; 34: 1288-396.
  3. Smith G, Clark JM. Elimination of fluoroscopy use in a pediatric electrophysiology laboratory utilizing three-dimensional mapping. Pacing Clin Electrophysiol 2007; 30: 510-8. [CrossRef] Wan G, Shannon KM, Moore JP. Factors associated with fluoroscopy exposure during pediatric catheter ablation utilizing electroanatomical mapping. J Interv Card Electrophysiol 2012; 35: 235-42.
  4. Efstathopoulos EP, Katritsis DG, Kottou S, Kalivas N, Tzanalaridou E, Giazitzoglou E, et al. Patient and staff radiation dosimetry during cardiac electrophysiology studies and