Dergiler / The Anatolian Journal of Cardiology / 2018 / Cilt: 20 - Sayı: 6

Transcatheter device closure of atrial septal defects guided completely by transthoracic echocardiography: A single cardiac center experience with 152 cases

Sayfa
230–235
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

In our comparative studies, no statistically significant differences were observed in success rates and complications.Conclusion: Transcatheter device closure of ASDs guided completely by TTE may be safe and effective and can be an alternative to traditional methods. (Anatol J Cardiol 2018; 20: 330-5)

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: This study aimed to assess the safety and feasibility of transcatheter device closure of atrial septal defects (ASDs) guided completely by transthoracic echocardiography (TTE).Methods: A total of 152 patients underwent transcatheter device closure of ASDs guided completely by TTE in our center from September 2014 to June 2017.
📊
Temel Bulgular & Veri:We used routine delivery sheaths during the procedure and then closed the ASDs by releasing a domestic occluder.Results: The closure was successful in 150 patients, and surgical repair was required in two patients.
💡
Sonuç & Katkı:In our comparative studies, no statistically significant differences were observed in success rates and complications.Conclusion: Transcatheter device closure of ASDs guided completely by TTE may be safe and effective and can be an alternative to traditional methods. (Anatol J Cardiol 2018; 20: 330-5)
🔬Tür:Araştırma Makalesi
📍Kapsam:2014 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

Objective: This study aimed to assess the safety and feasibility of transcatheter device closure of atrial septal defects (ASDs) guided completely by transthoracic echocardiography (TTE).Methods: A total of 152 patients underwent transcatheter device closure of ASDs guided completely by TTE in our center from September 2014 to June 2017. We used routine delivery sheaths during the procedure and then closed the ASDs by releasing a domestic occluder.Results: The closure was successful in 150 patients, and surgical repair was required in two patients. The size of the deployed occluder ranged from 10 mm to 38 mm (21.4±8.5 mm), and the procedure duration ranged from 30 to 90 min (38.2±21.4 min). No fatal complications were observed. Minor complications included transient arrhythmias (n=12) during the process of device deployment. The follow-up period was 3 months to 2 years, with no occluder dislodgment, residual fistula, or thrombus-related complications. In our comparative studies, no statistically significant differences were observed in success rates and complications.Conclusion: Transcatheter device closure of ASDs guided completely by TTE may be safe and effective and can be an alternative to traditional methods. (Anatol J Cardiol 2018; 20: 330-5)

🔖

Bu Makaleye Atıf Yap

CHEN, Q., CAO, H., ZHANG, G., CHEN, L., LU, H., YU, L. (2018). Transcatheter device closure of atrial septal defects guided completely by transthoracic echocardiography: A single cardiac center experience with 152 cases. The Anatolian Journal of Cardiology, Cilt: 20 - Sayı: 6, 230–235. https://ajindex.com/articles/365289

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Luo H, Wang J, Qiao C, Zhang X, Zhang W, Song L. Evaluation of different minimally invasive techniques in the surgical treatment of atrial septal defect. J Thorac Cardiovasc Surg 2014; 148: 188-93
  2. Vida VL, Tessari C, Fabozzo A, Padalino MA, Barzon E, Zucchetta F, et al. The evolution of the right anterolateral thoracotomy technique for correction of atrial septaldefects: cosmetic and functional results in prepubescent patients. Ann Thorac Surg 2013; 95: 242-7
  3. Hoashi T, Yazaki S, Kagisaki K, Kitano M, Kubota SM, Shiraishi I, et al. Management of ostium secundum atrial septal defect in the era of percutaneous trans-catheter device closure: 7-Year experience at a single institution. J Cardiol 2015; 65: 418-22
  4. Aytemir K, Oto A, Özkutlu S, Canpolat U, Kaya EB, Yorgun H, Şahiner L, et al. Transcatheter interatrial septal defect closure in a large cohort: midterm follow-up results. Congenit Heart Dis 2013; 8: 418-27
  5. Cao H, Chen Q, Zhang GC, Chen LW, Qiu ZH, Lu H. Percutaneous device closure of atrial septal defect with totally transthoracic echocardiography guide, without x-ray machine. Medicine (Baltimore) 2016; 95: e5256
  6. Mills NL, King TD, Thompson SL. Umbrella catheter for nonoperative closure of atrial septal defects. Med Instrum 1978; 12: 65-9
  7. Liang T, XiangJun Z, XiaoJing M, Yun L, Leng CY. New minimally invasivetechnique to occlude secundum atrial septal defect in 53 patients. Ann Thorac Surg 2006; 81: 1417-9
  8. Hongxin L, Wenbin G, Lijun S, Zhengjun W, Hao L, Chengwei Z, et al. Intraoperative device closure of secundum atrial septal defect using a right anterior minithoracotomy in 100 patients. J Thorac Cardiovasc Surg 2007; 134: 946-51
  9. Taniguchi M, Akagi T, Kijima Y, Sano S. Clinical advantage of realtime three-dimensional transesophageal echocardiography for transcatheter closure of multiple atrial septal defects. Int J Cardiovasc Imaging 2013; 29: 1273-80
  10. Mazic U, Gavora P, Masura J. The role of transesophageal echocardiography in transcatheter closure of secundum atrial septal defects by the Amplatzer septal occluder. Am Heart J 2001; 142: 482-8
  11. Kobayashi T. Monitoring tool of transcatheter atrial septal defect: transesophageal echocardiography or transthoracic echocardiography? J Cardiol 2015; 65: 1
  12. Bartakian S, El-Said HG, Printz B, Moore JW. Prospective randomized trial of transthoracic echocardiography versus transesophageal echocardiography for assessment and guidance of transcatheter closure of atri