Dergiler / The Anatolian Journal of Cardiology / 2018 / Cilt: 19 - Sayı: 4

Emine Hekim Yılmaz, Mustafa Orhan Bulut, Mehmet Küçük, İlker Kemal Yücel, Abdullah Erdem1 , Ahmet Çelebi

Sayfa
232–236
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

The procedure was successful and stable results were obtained during follow-up in all cases.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: To report clinical and procedural characteristics of twelve patients who received a covered stent for the treatment of aortic coarctationand concurrent patent ductus arteriosus (PDA).Methods: A single center database was retrospectively evaluated to obtain data of patients with combined aortic coarctation and PDA.
📊
Temel Bulgular & Veri:The stent length was chosen so as to cover the entirelength of the lesion from healthy to healthy tissue and also cover the ampulla of PDA.Results: The median age of the patients was 15 (range, 6.5-35) years.
💡
Sonuç & Katkı:The procedure was successful and stable results were obtained during follow-up in all cases.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Objective: To report clinical and procedural characteristics of twelve patients who received a covered stent for the treatment of aortic coarctationand concurrent patent ductus arteriosus (PDA).Methods: A single center database was retrospectively evaluated to obtain data of patients with combined aortic coarctation and PDA. Weselected patients in whom a covered stent was used for the treatment of both pathologies. The stent length was chosen so as to cover the entirelength of the lesion from healthy to healthy tissue and also cover the ampulla of PDA.Results: The median age of the patients was 15 (range, 6.5-35) years. The diameter of the coarctated segment increased from a median of 8.4(range, 2.6-10.8) mm to 16 (range, 9-24) mm (p<0.005), whereas the pressure gradient decreased from a median of 43 (range, 10-71) mm Hg to 0(range, 0-8) mm Hg (p<0.005). Fourteen covered stents were used for 12 patients. Following deployment, seven stents were flared with larger andlow-pressure balloons because of the gap between the distal end of the stent and the poststenotic dilated segment of the aorta, which causedresidual PDA shunts and/or instability of the stent. After the procedure, no residual PDA shunt was present in any patient.Conclusion: To the best of our knowledge, this study includes the largest series of patients reported in literature in whom covered CP stents wereused for simultaneous percutaneous treatment of coarctation and PDA. The procedure was successful and stable results were obtained during follow-up in all cases.

🔖

Bu Makaleye Atıf Yap

YIMAZ, E. H., BULUT, M. O., KÜÇÜK, M., YÜCEL, İ. K., ERDEM, A., ÇELEBİ, A. (2018). Emine Hekim Yılmaz, Mustafa Orhan Bulut, Mehmet Küçük, İlker Kemal Yücel, Abdullah Erdem1 , Ahmet Çelebi. The Anatolian Journal of Cardiology, Cilt: 19 - Sayı: 4, 232–236. https://ajindex.com/articles/365254

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (5)

  1. Canniffe C, Ou P, Walsh K, Bonnet D, Celermajer D. Hypertension after repair of aortic coarctation--a systematic review. Int J Cardiol 2013; 167: 2456-61. [CrossRef] Bhalgat PS, Pinto R, Dalvi BV. Transcatheter closure of large patent ductus arteriosus with severe pulmonary arterial hypertension: Short and intermediate term results. Ann Pediatr Cardiol 2012; 5: 135-40. [CrossRef] Baruteau AE, Hascoet S, Baruteau J, Boudjemline Y, Lambert V, Angel CY, et al. Transcatheter closure of patent ductus arteriosus: past, present and future. Arch Cardiovasc Dis 2014; 107: 122-32.
  2. Vanagt WY, Cools B, Boshoff DE, Frerich S, Heying R, Troost E, et al. Use of covered Cheatham-Platinum stents in congenital heart disease. Int J Cardiol 2014; 175: 102-7. [CrossRef] Khan MS, Moore JW. Treatment of abdominal aortic pseudoaneurysm with covered stents in a pediatric patient. Catheter Cardiovasc Interv 2000; 50: 445-8. [CrossRef] Chang ZP, Jiang SL, Xu ZY, Zhang GJ, Huang LJ, Zhao SH, et al. Use of covered Cheatham-Platinum stent as the primary modality in the treatment for native coarctation of the aorta. Chin Med J (Engl) 2012; 125: 1005-9.
  3. Singhi AK, Sivakumar K. Different transcatheter strategies for aortic coarctation associated with patent ductus arteriosus. Indian Heart J 2012; 64: 423-6. [CrossRef] Rao PS, Koscik R. Validation of risk factors in predicting recoarctation after initially successful balloon angioplasty for native aortic coarctation. Am Heart J 1995; 130: 116-21. [CrossRef] Krichenko A, Benson LN, Burrows P, Moes CAF, McLaughlin P, Freedom RM. Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol 1989; 67: 877-80. [CrossRef] Kulkarni S, Vimala J, Parmar R. Single therapeutic catheterization for treatment of native coarctation of aorta and large patent ductus arteriosus using a covered stent. Indian Heart J 2005; 57: 713-6.
  4. Sadiq M, Malick NH, Qureshi SA. Simultaneous treatment of native coarctation of the aorta combined with patent ductus arteriosus using a covered stent. Catheter Cardiovasc Interv 2003; 59: 387-90.
  5. Hakim F, Hawelleh AA, Goussous Y, Hijazi ZM. Simultaneous stent implantation for coarctation of the aorta and closure of patent ductus arteriosus using the Amplatzer duct occluder. Cathet Cardiovasc Interv 1999; 47: 36-8. [CrossRef] Geggel RL, Hijazi ZM, Rhodes J. Interventional cardiac catheterization therapy for combined coarctation of the aorta an