Dergiler / The Anatolian Journal of Cardiology / 2020 / Cilt: 24 - Sayı: 6

Twelve-month clinical outcomes of sirolimus-eluting stent in coronary artery disease: An experience in real-world Indian patients

Sayfa
364–369
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Only three incidences of stent thrombosis were found at the 12-month follow-up.Conclusion: The study results showed excellent safety and clinical effectiveness of Supraflex in a high proportion of high-risk real-world Indianpatients with coronary artery disease. (Anatol J Cardiol 2020; 24: 364-9)

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Objective: Supraflex (Sahajanand Medical Technologies Pvt.
📊
Temel Bulgular & Veri:Ltd, Surat, India) is the latest generation of biodegradable polymer-coated sirolimus-eluting coronary stent designed on ultra-thin (60 μm) cobalt–chromium platform with flexible “S-link.” The present study was designed toestablish the safety and clinical performance of Supraflex in real-world Indian patients with coronary artery disease.Methods: The study included 839 consecutive patients with coronary artery disease who were implanted with Supraflex from January 2014 toAugust 2017 at six different tertiary care centers in India.
💡
Sonuç & Katkı:Only three incidences of stent thrombosis were found at the 12-month follow-up.Conclusion: The study results showed excellent safety and clinical effectiveness of Supraflex in a high proportion of high-risk real-world Indianpatients with coronary artery disease. (Anatol J Cardiol 2020; 24: 364-9)
🔬Tür:Araştırma Makalesi
📍Kapsam:2014 Verileri
⚙️Değişkenler:Alan Parametreleri

Özet

Objective: Supraflex (Sahajanand Medical Technologies Pvt. Ltd, Surat, India) is the latest generation of biodegradable polymer-coated sirolimus-eluting coronary stent designed on ultra-thin (60 μm) cobalt–chromium platform with flexible “S-link.” The present study was designed toestablish the safety and clinical performance of Supraflex in real-world Indian patients with coronary artery disease.Methods: The study included 839 consecutive patients with coronary artery disease who were implanted with Supraflex from January 2014 toAugust 2017 at six different tertiary care centers in India. Follow-up was performed at 30 days, 6 months, and 12 months after the index procedure.The primary end-point of the study was the incidence of major adverse cardiac events (MACE), a composite of cardiac death, myocardialinfarction (MI), and target lesion revascularization (TLR) at the 12-month follow-up. The occurrence of stent thrombosis was analyzed as safetyend-point.Results: A total of 1025 lesions were treated by implantation of 1098 Supraflex stents. At the 12-month follow-up, MACE was 4.92%, including7 (0.86%) cardiac deaths, 16 (1.97%) MI, and 17 (2.09%) TLR. Only three incidences of stent thrombosis were found at the 12-month follow-up.Conclusion: The study results showed excellent safety and clinical effectiveness of Supraflex in a high proportion of high-risk real-world Indianpatients with coronary artery disease. (Anatol J Cardiol 2020; 24: 364-9)

🔖

Bu Makaleye Atıf Yap

NATHANI, S., RAHEEM, A., SANADHYA, H., PUROHIT, P. C., PATEF, R., ALANE, P. K., AGARWAL, D., SINHA, R. (2020). Twelve-month clinical outcomes of sirolimus-eluting stent in coronary artery disease: An experience in real-world Indian patients. The Anatolian Journal of Cardiology, Cilt: 24 - Sayı: 6, 364–369. https://ajindex.com/articles/365214

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (12)

  1. Wang CL, Chu PH. Echocardiography for Evaluation of Oncology Therapy-Related Cardiotoxicity. Acta Cardiol Sin 2016; 32: 560-4
  2. Roth GA, Johnson C, Abajobir A, Abd-Allah F, Abera SF, Abyu G, et al. Global, regional, and national burden of cardiovascular diseases for 10 causes, 1990 to 2015. J Am Coll Cardiol 2017; 70: 1-25
  3. Iqbal J, Gunn J, Serruys PW. Coronary stents: historical development, current status and future directions. Br Med Bull 2013; 106: 193-211
  4. Ho MY, Chen CC, Wang CY, Chang SH, Hsieh MJ, Lee CH, et al. The development of coronary artery stents: from bare-metal to bioresorbable types. Metals 2016; 6: 168
  5. Foerst J, Vorpahl M, Engelhardt M, Koehler T, Tiroch K, Wessely R. Evolution of coronary stents: From bare-metal stents to fully biodegradable, drug-eluting stents. Combination Products in Therapy 2013; 3: 9-24
  6. Pellegrini DO, Gomes VO, Lasevitch R, Smidt L, Azeredo MA, Ledur P, et al. Efficacy and safety of drug-eluting stents in the real world: 8-year follow-up. Arq Bras Cardiol 2014; 103: 174-82
  7. Lemos PA, Chandwani P, Saxena S, Ramachandran PK, Abhyankar A, Campos CM, et al. Clinical outcomes in 995 unselected realworld patients treated with an ultrathin biodegradable polymercoated sirolimus-eluting stent: 12-month results from the FLEX Registry. BMJ Open 2016; 6: e010028
  8. Zaman A, de Winter RJ, Kogame N, Chang CC, Modolo R, Spitzer E, et al. Safety and efficacy of a sirolimus-eluting coronary stent with ultra-thin strut for treatment of atherosclerotic lesions (TALENT): a prospective multicentre randomised controlled trial. Lancet 2019; 393: 987-97
  9. Shetty R, Prajapati J, Pai U, Shetty K. Preliminary Evaluation of Clinical and Angiographic Outcomes with Biodegradable Polymer Coated Sirolimus-Eluting Stent in De Novo Coronary Artery Disease: Results of the MANIPAL-FLEX Study. Scientifica (Cairo) 2016; 2016: 9324279
  10. Cutlip DE, Windecker S, Mehran R, Boam A, Cohen DJ, van Es GA, et al. Clinical end points in coronary stent trials: a case for standardized definitions. Circulation 2007; 115: 2344-51
  11. Thygesen K, Alpert JS, Jaffe AS, Simoons ML, Chaitman BR, White HD, et al.; Writing Group on the Joint ESC/ACCF/AHA/WHF Task Force for the Universal Definition of Myocardial Infarction; ESC Committee for Practice Guidelines (CPG). Third universal definition of myocardial infarction. Eur Heart J 2012; 33: 2551-67
  12. Wykrzykowska J, Serruys P, Buszman P, Linke A, Ischinger T, Klauss V, et al. The three year