Dergiler / Tesisat Mühendisliği / 2021 / Cilt: 2021 - Sayı: 184

Biyoaerosol Kompozisyonu ve Karbondioksit (CO2 ) Düzeyinin Covid-19 Salgın Sürecinin Başlangıcında Bir Spor Salonunda Araştırılması

Investigation of Bioaerosol Composition and CO2 Levels in a Gym During the Early Phase of Covid-19 Pandemics

Sayfa
29–38
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Ortamdaki kişi sayısı ile bakteri ve CO2 düzeyleri arasında lineer ilişki bulunmuştur (r2 ~ 0,7).İç ve dış ortamda sıklıkla gözlenen Aspergillus, Penicillium, Cladosporium ve Alternariamantar türlerine ilaveten; deri ve/ya saç mantar enfeksiyonuna neden olan Microsporumve Trichophyton; insan patojeni Nigrospora ile su sızıntısı olan binalarda kullanılan izolasyon köpüğünde büyüyen Stachybotrys türlerine ise spor salonlarının sadece iç ortamhavasında rastlanılmıştır.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Bu çalışma, Covid-19 salgınının ülkemizde resmi olarak ilk vakanın gözlendiği tarihlerde, çalışmaya gönüllü olarak katılan bir spor salonunda 3 farklı günde (10-12 Mart2020) gerçekleştirilmiştir.
📊
Temel Bulgular & Veri:Bu çalışmada biyoaerosollerin tür vemiktar tayini ile sıcaklık, bağıl nem, atmosferik basınç ve karbon dioksit (CO2) düzeylerispor salonunun içinde ve dış ortam havasında eşzamanlı olarak ölçülmüştür.Spor salonunda en yüksek CO2 seviyeleri aktivite sırasında ve/ya aktivitelerden hemensonra ölçülmüştür.
💡
Sonuç & Katkı:Ortamdaki kişi sayısı ile bakteri ve CO2 düzeyleri arasında lineer ilişki bulunmuştur (r2 ~ 0,7).İç ve dış ortamda sıklıkla gözlenen Aspergillus, Penicillium, Cladosporium ve Alternariamantar türlerine ilaveten; deri ve/ya saç mantar enfeksiyonuna neden olan Microsporumve Trichophyton; insan patojeni Nigrospora ile su sızıntısı olan binalarda kullanılan izolasyon köpüğünde büyüyen Stachybotrys türlerine ise spor salonlarının sadece iç ortamhavasında rastlanılmıştır.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Bu çalışma, Covid-19 salgınının ülkemizde resmi olarak ilk vakanın gözlendiği tarihlerde, çalışmaya gönüllü olarak katılan bir spor salonunda 3 farklı günde (10-12 Mart2020) gerçekleştirilmiştir. Çalışma sırasında salondaki kişi sayısı ve çeşitli parametrelerde kaydedilmiştir. Çalışmanın yapıldığı spor salonunda eğitmen gözetiminde bayanlartoplu olarak pilates aktivitesini gerçekleştirmiştir. Bu çalışmada biyoaerosollerin tür vemiktar tayini ile sıcaklık, bağıl nem, atmosferik basınç ve karbon dioksit (CO2) düzeylerispor salonunun içinde ve dış ortam havasında eşzamanlı olarak ölçülmüştür.Spor salonunda en yüksek CO2 seviyeleri aktivite sırasında ve/ya aktivitelerden hemensonra ölçülmüştür. Spor salonunda toplam bakteri ve mantar seviyeleri 102 ila >103CFU/m3 arasında bulunmuştur. İç ortamda havadan kaynaklı bakteri düzeyleri en düşükaktivite öncesinde ve en yüksek aktivite sırasında ve/ya sonrasında gözlenmiştir. Ortamdaki kişi sayısı ile bakteri ve CO2 düzeyleri arasında lineer ilişki bulunmuştur (r2 ~ 0,7).İç ve dış ortamda sıklıkla gözlenen Aspergillus, Penicillium, Cladosporium ve Alternariamantar türlerine ilaveten; deri ve/ya saç mantar enfeksiyonuna neden olan Microsporumve Trichophyton; insan patojeni Nigrospora ile su sızıntısı olan binalarda kullanılan izolasyon köpüğünde büyüyen Stachybotrys türlerine ise spor salonlarının sadece iç ortamhavasında rastlanılmıştır.

Abstract

This study was carried out on 3 different days (10-12 March 2020) in a gym that voluntarily participated in the study, on the dates when the first case of Covid-19 was officially observed in our country. The number of people in the gym and various parameters were recorded. In the gym where the study was carried out, the women carried out the pilates activity collectively under the supervision of the instructor. In this study, composition of bioaerosols and temperature, relative humidity, atmospheric pressure and carbon dioxide (CO2 ) levels in the air were measured simultaneously inside the gym and the outdoor air. The highest CO2 levels were measured during and/or immediately after the activities in the gym. The total bacteria and mold levels in the gym were between 102 and > 103 CFU/ m3 . In indoor environment, the lowest airborne bacteria levels were observed before the activity and the highest levels were observed during and/or after the activity. A linear relationship was found between the number of people in the gym and the airborne bacteria and CO2 levels (r2 ~ 0,7). In addition to Aspergillus, Penicillium, Cladosporium and Alternaria, which are frequently observed fungi species both indoor and outdoor; Microsporum and Trichophyton, which are known to cause fungal infections of the skin and/or hair; the human pathogen Nigrospora and Stachybotrys species growing in the insulation foam used in buildings with water leakage were found only in the indoor air of the gym. It is concluded here that the environmental conditions and individual health conditions are important in terms of spread of diseases.

🔖

Bu Makaleye Atıf Yap

MENTEŞE, S., ATEŞ, G. Ö., AYDIN, M., OTKUN, M. T. (2021). Biyoaerosol Kompozisyonu ve Karbondioksit (CO2 ) Düzeyinin Covid-19 Salgın Sürecinin Başlangıcında Bir Spor Salonunda Araştırılması. Tesisat Mühendisliği, Cilt: 2021 - Sayı: 184, 29–38. https://ajindex.com/articles/364938

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. WHO, “Air Pollution and Cancer”, IARC Scientific Publication No. 161, Geneva, WHO, 2013
  2. Payne-Sturges, D.C., Burke, T.A., Breysse, P., Diener-West, M., Buckley, T.J., “Personal Exposure Meets Risk Assessment: A Comparison of Measured and Modeled Exposures and Risks in an Urban Community”, Environ Health Perspect, 2004,112: 589-98
  3. Habil, M., Massey, D., Taneja, A., “Exposure From Particle and Ionic Contamination to Children in Schools of India”, Atmos. Poll. Res., 2015, 6: 719-725
  4. Dales, R.E., Zwanenburg, H., Burnett, R., Franklin, C.A., “Respiratory Health Effects of Home Dampness and Molds Among Children”, Am. J. Epidemiol, 1991, 134: 196-203
  5. Cox, C.S., “Bioaresols Handbook”, Ed: Wathes CM., Lewis Publishers/CRC Press, Inc., Boca Raton, Florida, 1995
  6. Menteşe, S., Taşdibi, D., “Airborne Bacteria Levels in Indoor Urban Environments: The Influence of Heating Season and Prevalence of Sick Building Syndrome (SBS)", Indoor And Built Environment, 2016, 25: 563-580
  7. Mentese, S., Mirici, N.A., Elbir, T., Palaz, E., Mumcuoğlu, D.T., Cotuker, O., Bakar, C., Oymak, S., Otkun, M.T., “A Long-Term Multi-Parametric Monitoring Study: Indoor Air Quality (IAQ) and the Sources of the Pollutants, Prevalence of Sick Building Syndrome (SBS) Symptoms, and Respiratory Health Indicators”, Atmospheric Pollution Research, 2020, 11: 2270-2281
  8. Mentese, S., Arisoy, M., Rad, A., Güllü, G., “Bacteria and Fungi Levels in Various Indoor and Outdoor Environments in Ankara, Turkey”, CLEAN-Soil, Air, Water, 2009, 37(6): 487-493
  9. Mentese, S., Rad, A. Y., Arısoy, M., Güllü, G., “Seasonal and Spatial Variations of Bioaerosols in Indoor Urban Environments, Ankara, Turkey. Indoor and built environment, 2012, 21(6): 797-810
  10. Menteşe, S., Yousefi Rad, A., Arısoy, M., Güllü, G., “Seasonal And Spatial Variations Of Bioaerosols In Indoor Urban Environments, Ankara, Turkey", Indoor and Built Environment, 2012, 21: 797-810
  11. Müezzinoğlu, A., 2000, Hava Kirliliğinin ve Kontrolünün Esasları. İzmir: Dokuz Eylül Yayınları
  12. Mitscherlich, G., 1995, “Die Welt in Der Wir Leben. Entstehung – Entwicklung, Heutige Stand Rombach Ökologie”, Rombach Verlag, Freiburg
  13. ASHRAE, “ASHRAE Handbook CD, Fundamentals. Chapter 9: Indoor Environmental Health”, Atlanta, USA, 2003
  14. Düzovali, G., “Kapalı Ortam Hava Kirliliği ve Çözümleri: Kahvehane ve Okul Durumu”. Doktara Tezi. Ondokuz Mayıs Üniversitesi, Samsun, 2007
  15. Heudorf, U., Neitzert, V., Spark J., “Part