Dergiler / Diagnostic and Interventional Radiology / 2016 / Cilt: 22 - Sayı: 5

Inferior vena cava filter insertion through the popliteal vein: enabling the percutaneous endovenous intervention of deep vein thrombosis with a single venous access approach in a single session

Sayfa
455–459
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:PURPOSE We aimed to evaluate the efficiency of placing an inferior vena cava (IVC) filter through the same popliteal vein access site used for percutaneous endovenous intervention in patients with extensive lower extremity deep vein thrombosis.
📊
Temel Bulgular & Veri:METHODS This retrospective study included 21 patients who underwent IVC filter insertion through the popliteal vein over a three-year period.
💡
Sonuç & Katkı:CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention.
🔬Tür:Literatür & Derleme Çalışması
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

PURPOSE We aimed to evaluate the efficiency of placing an inferior vena cava (IVC) filter through the same popliteal vein access site used for percutaneous endovenous intervention in patients with extensive lower extremity deep vein thrombosis. METHODS This retrospective study included 21 patients who underwent IVC filter insertion through the popliteal vein over a three-year period. Patient medical records were reviewed for the location of the deep vein thrombosis, result of filter removal, and total number of endovascular procedures needed for filter insertion and recanalization of the lower extremity venous system. Follow-up lower extremity computed tomography (CT) venography was also reviewed in each patient to assess the degree of filter tilt in the IVC. RESULTS All patients had extensive lower extremity deep vein thrombosis involving the iliac vein and/or femoral vein. Seventeen patients showed deep vein thrombosis of the calf veins. In all patients, IVC filter insertion and the recanalization procedure were performed during a single procedure through the single popliteal vein access site. In the 17 patients undergoing follow-up CT, the mean tilt angle of the filter was 7.14°±4.48° in the coronal plane and 8.77°±5.49° in the sagittal plane. Filter retrieval was successful in 16 of 17 patients (94.1%) in whom filter retrieval was attempted. CONCLUSION Transpopliteal IVC filter insertion is an efficient technique that results in low rates of significant filter tilt and enables a single session procedure using a single venous access site for filter insertion and percutaneous endovenous intervention.

🔖

Bu Makaleye Atıf Yap

KİM, H. O., KİM, J. K., PARK, J. G., YİM, N. Y., KANG, Y. J., JUNG, H. D. (2016). Inferior vena cava filter insertion through the popliteal vein: enabling the percutaneous endovenous intervention of deep vein thrombosis with a single venous access approach in a single session. Diagnostic and Interventional Radiology, Cilt: 22 - Sayı: 5, 455–459. https://ajindex.com/articles/350063

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (2)

  1. Chung J, Owen RJ. Using inferior vena cava fil- ters to prevent pulmonary embolism. Can Fam Physician 2008; 54:49-55.
  2. Yamagami T, Nishimura T. Prophylactic implan- tation of inferior vena cava filter during endo- vascular therapies for deep venous thrombosis of the lower extremities. Ann Vasc Dis 2011; 4:19-23. [CrossRef] Kolbel T, Alhadad A, Acosta S, Lindh M, Ivancev K, Gottsater A. Thrombus embolization into IVC filters during catheter-directed thrombolysis for proximal deep venous thrombosis. J Endo- vasc Ther 2008; 15:605-613. [CrossRef] Caplin DM, Nikolic B, Kalva SP, Ganguli S, Saad WE, Zuckerman DA; Society of Interventional Radiology Standards of Practice Committee. Quality improvement guidelines for the perfor- mance of inferior vena cava filter placement for the prevention of pulmonary embolism. J Vasc Interv Radiol 2011; 22:1499-1506. [CrossRef] Deitelzweig SB, Johnson BH, Lin J, Schulman KL. Prevalence of clinical venous thromboembolism in the USA: current trends and future projections. Am J Hematol 2011; 86:217-220. [CrossRef] Anderson FA, Zayaruzny M, Heit JA. Estimated annual numbers of US acute-care hospital pa- tients at risk for venous thromboembolism. Am J Hematol 2007; 82:777-782. [CrossRef] Comerota AJ, Throm RC, Mathias SD, Haughton S, Mewissen M. Catheter-directed thromboly- sis for iliofemoral deep venous thrombosis im- proves health-related quality of life. J Vasc Surg 2000; 32:130-137. [CrossRef] Hood DB, Alexander JQ. Endovascular manage- ment of iliofemoral venous occlusive disease. Surg Clin North Am 2004; 84:1381-1396, viii. [CrossRef] Kolbel T, Lindh M, Holst J, et al. Extensive acute deep vein thrombosis of the iliocaval segment: midterm results of thrombolysis and stent placement. J Vasc Interv Radiol 2007; 18:243- 250. [CrossRef] Thery C, Bauchart JJ, Lesenne M, et al. Predic- tive factors of effectiveness of streptokinase in deep venous thrombosis. Am J Cardiol 1992; 69:117-122. [CrossRef] Sharifi M, Bay C, Skrocki L, Lawson D, Mazdeh S. Role of IVC filters in endovenous therapy for deep venous thrombosis: The FILTER-PEVI (fil- ter implantation to lower thromboembolic risk in percutaneous endovenous intervention) tri- al. Cardiovasc Intervent Radiol 2012; 35:1408- 1413. [CrossRef] Angel LF, Tapson V, Galgon RE, Restrepo MI, Kaufman J. Systematic review of the use of re- trievable inferior vena cava filters. J Vasc Interv Radiol 2011; 22:1522-1530. [CrossRef] Singer MA, Wang SL. Modeling blood flow in a tilted inferior ve