Dergiler / Diagnostic and Interventional Radiology / 2017 / Cilt: 23 - Sayı: 2

Ten-year experience of retrievable inferior vena cava filters in a tertiary referral center

Sayfa
144–149
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

A departmental protocol is recommended to ensure the filter is removed where appropriate and possible.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:PURPOSE A significant proportion of patients undergoing surgery have an increased incidence of acute pulmonary embolus (PE).
📊
Temel Bulgular & Veri:Results of all clinical investigations (including computed tomography, magnetic reso-nance imaging, ultrasonography, and plain radiography) while the IVC filters were in situ were reviewed.RESULTSIn total, 393 retrievable IVC filters were inserted, 254 with the indication of preoperative throm-boembolic prophylaxis.
💡
Sonuç & Katkı:A departmental protocol is recommended to ensure the filter is removed where appropriate and possible.
🔬Tür:Literatür & Derleme Çalışması
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Abstract

PURPOSE A significant proportion of patients undergoing surgery have an increased incidence of acute pulmonary embolus (PE). We analyzed all patients who had a retrievable inferior vena cava (IVC) filter placed preoperatively for PE prophylaxis and investigated the long-term outcomes of the patients who did not have their filter removed.METHODSPatients who underwent retrievable IVC filter insertion and attempted removal were identified from the radiology information systems database in a large tertiary referral university teaching hospital. Results of all clinical investigations (including computed tomography, magnetic reso-nance imaging, ultrasonography, and plain radiography) while the IVC filters were in situ were reviewed.RESULTSIn total, 393 retrievable IVC filters were inserted, 254 with the indication of preoperative throm-boembolic prophylaxis. Recurrent PE was reported in five patients (1.9%) despite the IVC filter. Of the 254 retrievable filters inserted prior to surgery, an attempt at retrieval was made in 168 filters (66.1%). Successful retrieval at the first attempt occurred in 143 cases (85.1%), while 25 cases failed or were aborted (14.9%). No attempt at retrieval was made in 86 (33.9%) patients and a significant proportion of these patients had undergone cancer surgery (P < 0.0107). In those pa-tients where there was no attempt at retrieval, there was an association between cancer surgery and a shorter absolute survival time (P < 0.0001).CONCLUSIONThe majority of attempted filter retrievals were successful, and a proportion of nonretrieved IVC filters are accounted for in patients who underwent cancer surgery and ultimately died with the filter in situ. A departmental protocol is recommended to ensure the filter is removed where appropriate and possible.

🔖

Bu Makaleye Atıf Yap

TSE, G., CLEVELAND, T., GOODE, S. (2017). Ten-year experience of retrievable inferior vena cava filters in a tertiary referral center. Diagnostic and Interventional Radiology, Cilt: 23 - Sayı: 2, 144–149. https://ajindex.com/articles/350041

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (15)

  1. Fowkes FJI, Price JF, Fowkes FGR. Incidence of diagnosed deep vein thrombosis in the gen- eral population: Systematic review. Eur J Vasc Endovasc Surg 2003
  2. [CrossRef] Desciak MC, Martin DE. Perioperative pulmonary embolism: diagnosis and anesthetic manage- ment. J Clin Anesth 2011
  3. [CrossRef] Geerts W, Cook D, Selby R, Etchells E. Venous thromboembolism and its prevention in criti- cal care. J Crit Care 2002
  4. [CrossRef] Berczi V, Bottomley JR, Thomas SM, Taneja S, Gaines PA, Cleveland TJ. Long-term retrievabili- ty of IVC filters: should we abandon permanent devices? Cardiovasc Intervent Radiol 2007
  5. [CrossRef] Angel LF, Tapson V, Galgon RE, Restrepo MI, Kaufman J. Systematic review of the use of re- trievable inferior vena cava filters. J Vasc Interv Radiol 2011
  6. [CrossRef] Uberoi R, Tapping C, Chalmers N, Allgar V. Brit- ish Society of Interventional Radiology (BSIR) Inferior Vena Cava (IVC) Filter Registry. Car- diovasc Intervent Radiol 2013
  7. [CrossRef] Lee MJ, Valenti D, de Gregorio MA, Minocha J, Rimon U, Pellerin O. The CIRSE retrievable IVC filter registry: retrieval success rates in practice. Cardiovasc Intervent Radiol 2015
  8. [CrossRef] Molvar C. Inferior vena cava filtration in the management of venous thromboembolism: filtering the data. Semin Intervent Radiol 2012
  9. [CrossRef] Iliescu B, Haskal Z. Advanced techniques for removal of retrievable inferior vena cava filters. Cardiovasc Intervent Radiol 2012
  10. [CrossRef] Grande WJ, Trerotola SO, Reilly PM, et al. Experi- ence with the recovery filter as a retrievable in- ferior vena cava filter. J Vasc Interv Radiol 2005
  11. [CrossRef] Kirilcuk NN, Herget EJ, Dicker RA, Spain DA, Hellinger JC, Brundage SI. Are temporary inferi- or vena cava filters really temporary? Am J Surg 2005
  12. [CrossRef] Peterson EA, Yenson PR, Liu D, Lee AYY. Pre- dictors of attempted inferior vena cava filters retrieval in a tertiary care centre. Thromb Res 2014
  13. [CrossRef] Cohoon KP, McBride J, Friese JL, McPhail IR. Retrievable inferior vena cava filters can be placed and removed with a high degree of success: Initial experience. Catheter Cardiovasc Interv 2015
  14. [CrossRef] Lee L, Taylor J, Munneke G, Morgan R, Belli AM. Radiology-led follow-up system for IVC filters: effects on retrieval rates and times. Cardiovasc Interv Radiol 2012
  15. [CrossRef] Lucas DJ, Du