Dergiler / Laparoscopic Endoscopic Surgical Science / 2020 / Cilt: 27 - Sayı: 2

Comparison of sealers used in laparoscopic cholecystectomy for cystic duct closure: An ex vivo study

Sayfa
48–52
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Thus, intraabdominal organ injuries will be lessened.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Introduction: To compare the safety and efficacy of Harmonic scalpel (HS) and Plasmakinetic (PK) sealer inachieving safe closure of the cystic ducts ex–vivo after the laparoscopic cholecystectomy.Materials and Methods: In this prospective study, 90 patients with symptomatic gallstone disease wereoperated using laparoscopic technic.
📊
Temel Bulgular & Veri:Then gallbladders were divided into three groups (n=30).
💡
Sonuç & Katkı:Thus, intraabdominal organ injuries will be lessened.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Introduction: To compare the safety and efficacy of Harmonic scalpel (HS) and Plasmakinetic (PK) sealer inachieving safe closure of the cystic ducts ex–vivo after the laparoscopic cholecystectomy.Materials and Methods: In this prospective study, 90 patients with symptomatic gallstone disease wereoperated using laparoscopic technic. Then gallbladders were divided into three groups (n=30). In all groups,gallbladders were removed with surgical clips. After the gallbladders removed, in first group, cystic ductsremain clipped (SC). In second and third groups, cystic ducts were sealed with HS and PK distally afterthe surgical clips removed. Then, twenty–gauge catheters were applied to fundic part of gallbladder andgallbladders filled with saline. An increasing pressure was applied through a sphygmomanometer. Burstingpressures were measured using invasive arterial blood pressure measurement device and measured systolic pressures were accepted bursting pressure. After bursting pressures were measured in three groups,results were written down to the SPSS table. Differences between HSvsSC, HSvsPK and SCvsPK groupswere calculated using paired–samples t–test.Results: In this study, the mean cystic duct bursting pressures were 332.46±4.62 mm Hg with SC, 326.56±4.53mmHg with PK and 343.06±4.28 mm Hg with HS. Differences in the mean cystic duct bursting pressures between HS vs. SC and HS vs. PK groups were indicated HS’s superiority (p=0.046 and p=0.026, respectively).On the contrary, SC vs. PK group was not indicated PK’s advantage; however, PK was found safely as muchas SC.Conclusion: HS and PK sealer could be an alternative and safe method for cystic duct closure, avoiding theclip displacement and migration of the clip. Single device usage was one of the most important advantagesof this technique. Thus, intraabdominal organ injuries will be lessened.

🔖

Bu Makaleye Atıf Yap

SUREL, A. A., KAVLAKOĞLU, B. (2020). Comparison of sealers used in laparoscopic cholecystectomy for cystic duct closure: An ex vivo study. Laparoscopic Endoscopic Surgical Science, Cilt: 27 - Sayı: 2, 48–52. https://ajindex.com/articles/345091

📄 Tam Metin PDF Okuyucu

📄

PDF görüntüleyici hazırlanıyor...

Kaynakça (13)

  1. Keus F, Broeders IA, van Laarhoven CJ. Gallstone disease: Surgical aspects of symptomatic cholecystolithiasis and acute cholecystitis. Best Pract Res Clin Gastroenterol 2006;20:1031–51
  2. Mufti TS, Ahmad S, Naveed D, Akbar M, Zafar A. Laparoscopic cholecystectomy: an early experience at Ayub Teaching Hospital Abbottabad. J Ayub Med Coll Abbottabad. 2007;19:42–4
  3. Yano H, Okada K, Kinuta M, Nakano Y, Tono T, Matsui S, et al. Efficacy of absorbable clips compared with metal clips for cystic duct ligation in laparoscopic cholecystectomy. Surg Today 2003;33:18–23
  4. Herline AJ, Fisk JM, Debelak JP, Shull HJ Jr, Chapman WC. Surgical clips: a cause of late recurrent gallstones. Am Surg 1998;64:845–8
  5. Hanazaki K, Igarashi J, Sodeyama H, Matsuda Y. Bile leakage resulting from clip displacement of the cystic duct stump: a potential pitfall of laparoscopic cholecystectomy. Surg Endosc 1999;13:168–71
  6. Kuroki T, Tajima Y, Tsuneoka N, Kitasato A, Adachi T, Mishima T, et al. Biliary navigation surgery using endoscopic nasobiliary drainage tube for the prevention of bile duct injury in laparoscopic cholecystectomy. Hepatogastroenterology 2007;54:1018–9
  7. Klein RD, Jessup G, Ahari F, Connolly RJ, Schwaitzberg SD. Comparison of titanium and absorbable polymeric surgical clips for use in laparoscopic cholecystectomy. Surg Endosc 1994;8:753–8
  8. Wang CJ, Yuen LT, Yen CF, Lee CL, Soong YK. Comparison of the efficacy of the pulsed bipolar system and conventional bipolar electrosurgery in laparoscopically assisted vaginal hysterectomy. J Laparoendosc Adv Surg Tech A 2005;15:361–4
  9. Westervelt J. Clipless cholecystectomy: broadening the role of the harmonic scalpel. JSLS 2004;8:283–5
  10. Shamiyeh A, Vattay P, Tulipan L, Schrenk P, Bogner S, Danis J, et al. Closure of the cystic duct during laparoscopic cholecystectomy with a new feedback-controlled bipolar sealing system in case of biliary obstruction--an experimental study in pigs. Hepatogastroenterology 2004;51:931–3
  11. Humes DJ, Ahmed I, Lobo DN. The pedicle effect and direct coupling: delayed thermal injuries to the bile duct after laparoscopic cholecystectomy. Arch Surg 2010;145:96–8
  12. Kapoor VK. Management of bile duct injuries: a practical approach. Am J Surg 2009;75:1157–60
  13. Carbonell AM, Joels CS, Kercher KW, Matthews BD, Sing RF, Heniford BT. A comparison of laparoscopic bipolar vessel sealing devices in the hemostasis of small-, medium-, and large-sized arteries. J Laparoendosc Adv Surg Tec