Temperature Effect of Silicone Oil at the Anterior Segment

Sayfa
10–14
DOI
—
🏛️Bu makalenin bibliyografik verileri ve tam metin bağlantısı DergiPark üzerinden sağlanmıştır.
DergiPark Kaydı ↗
✨

Yapay Zeka Hızlı Bakış & Çıkarımlar

AI Insight
⚡ TL;DR(1 Cümlede Hızlı Çıkarım)

Further studies are needed to confi rm our results.

📌 3 Maddede Bu Makale

🎯
Amaç & Hipotez:Purpose: To evaluate the effect of silicone oil tamponade on the central corneal temperature using noncontact infrared thermometer (NCIT) in vitrectomized eyes.
📊
Temel Bulgular & Veri:Methods: Sixty eyes of 60 patients who underwent pars plana vitrectomy and intraocular silicone oil tamponade were enrolled in this prospective study.
💡
Sonuç & Katkı:Further studies are needed to confi rm our results.
🔬Tür:Araştırma Makalesi
📍Kapsam:Genişletilmiş Akademik Örneklem
⚙️Değişkenler:Alan Parametreleri

Özet

Purpose: To evaluate the effect of silicone oil tamponade on the central corneal temperature using noncontact infrared thermometer (NCIT) in vitrectomized eyes. Methods: Sixty eyes of 60 patients who underwent pars plana vitrectomy and intraocular silicone oil tamponade were enrolled in this prospective study. Central corneal temperatures were measured by handheld NCIT from the corneal surface and these values were compared with the corneal temperatures of the contralateral eyes of the same subjects. Results: Statistically signifi cant difference was observed between silicone oil fi lled eye and contralateral nonoperated eye (p<0.001). There was a signifi cant correlation between temperature of silicone oil fi lled eye and contralateral eye (p<0.001). Statistically signifi cant negative correlation was observed between postoperative period and temperature of silicone oil fi lled eye (p=0.003). The mean values of temperatures were found to be higher statistically in phakic eyes compared with pseudophakic ones in both silicone oil fi lled and contralateral eye group (p=0.010, p=0.011, respectively). Conclusion: Silicon oil and acrylic and polymethylmethacrylate lenses may affect tissue metabolism because it changes heat conduction. Heat change in tissues can be responsible for complications. Further studies are needed to confi rm our results.

🔖

Bu Makaleye Atıf Yap

FICO, E. Ü., AYRANCI, Ö. O., MÜFTÜOĞLU, İ. K., ELTUTAR, K., ÇUBUK, M. Ö. (2020). Temperature Effect of Silicone Oil at the Anterior Segment. Retina-Vitreus, Cilt: 29 - Sayı: 1, 10–14. https://ajindex.com/articles/298789

Kaynakça (13)

  1. Flakner CI, Binder S, Kruger A. Outcome after silicone oil removal. Br J Ophthalmol. 2001;85:1203-1207
  2. McCuen BW 2nd, de Juan E Jr, Landers MB 3rd, Machemer R. Silicone oil in vitreoretinal surgery. Part 2: Results and complications. Retina. 1985 Fall-Winter;5(4):198-205
  3. Hutton WL, Azen SP, Blumenkranz MS, et al. The effects of silicone oil removal. Silicone Study Report 6. Arch Ophthalmol. 1994;112(6):778-85
  4. Abrams GW, Azen SP, Barr CC, et al. The incidence of corneal abnormalities in the Silicone Study. Silicone Study Report 7. Arch Ophthalmol. 1995;113:764-769
  5. Barr CC, Lai MY, Lean JS, et al. Postoperative intraocular pressure abnormalities in the Silicone Study: Silicone Study Report 4. Ophthalmology. 1993;100(11):1629–1635
  6. Abrams GW, Azen SP, Barr CC, et al. The incidence of corneal abnormalities in the Silicone Study. Silicone Study Report 7. Arch Ophthalmol. 1995;113(6):764–769
  7. Federman JL, Schubert HD. Complications associated with the use of silicone oil in 150 eyes after retina-vitreous surgery. Ophthalmology. 1988;95(7):870–876 8. Kreissl H, Neiger R. Measurement of body temperature in 300 dogs with a novel noncontact infrared thermometer on the cornea in comparison to a standard rectal digital thermometer. J Vet Emerg Crit Care (San Antonio). 2015 May-Jun;25(3):372-8. doi: 10.1111/vec.12302. Epub 2015 Apr 8
  8. Chiappini E, Sollai S, Longhi R, et al. Performance of noncontact infrared thermometer for detecting febrile children in hospital and ambulatory settings. J ClinNurs. 2011;20:1311– 1318
  9. Selent MU, Molinari NM, Baxter A, et al. Mass screening for fever in children: A comparison of 3 infrared thermal detection systems. Pediatr Emerg Care. 2013;29:305–313
  10. Teran CG, Torrez-Llanos J, Teran-Miranda TE, Balderrama C, Shah NS, Villarroel P. Clinical accuracy of a non-contact infrared skin thermometer in paediatric practice. Child Care Health Dev. 2012;38:471–476
  11. Oztas Z, Barut Selver O, Akkin C, Canturk E, Afrashi F. Correlation of Handheld Infrared Skin Thermometer and Infrared Videothermography Device for Measurement of Corneal Temperature. Eye Contact Lens. 2016;42(3):202-5
  12. Klamann MK, Maier AK, Gonnermann J, Klein JP, Pleyer U. Measurement of dynamic ocular surface temperature in healthy subjects using a new thermography device. Curr Eye Res. 2012;37:678–683
  13. Klamann MK, Klein JP, Maier AK, Gonnermann J, Pleyer U. Application possibilities of modernthermography— First experience with the new